9-26
Volta System Limitations
Volta System Temperature Limits
F °
C °
L i m i t
D e s c r i p t i o n
140
60
Maximum
storage temperature-
Do not store the pack at or above this tempera
ture. Doing so may cause the pack to overheat
and may result in a loss of performance and/or
a shortened life expectancy.
134.6
57
High temperature-
fault
Volta System shuts down and does not function
above this temperature.
131
55
High temperature-
warning
Volta System is near the high temperature fault.
SOC gauge may flash yellow or an indicator
may appear on the touchscreen.
125.6
52
High temperature
fault recovery
If the pack reaches the high temperature fault
limit (134.6°F or 52°C), the Volta System will not
restart until it cools below this temperature.
116.6
47
Too hot to charge
Above this temperature, the Volta System
powers devices, but the System will not charge,
even if connected to shore power.
109.4
43
Too hot to charge
recovery
If the pack reaches the too hot to charge
temperature (116.6°F or 47°C), the Volta System
will not allow charging again until it cools to this
temperature.
68
20
Heating control
off temperature
At this temperature, the pack heating control
turns off if previously on.
59
15
Heating control
on temperature
When the pack is below this temperature, the
pack heating control is on to actively warm the
pack.
42.8
6
Too cold to
charge recovery
If the pack reaches the too cold to charge
temperature (37.4°F or 3°C), the Volta System
will not allow charging again until it reaches
this temperature.
41
5
Low temperature
warning
Volta System is near the too cold to charge limit.
SOC gauge may flash blue or an indicator may
appear on the touchscreen.
37.4
3
Too cold to
charge temperature
Below this temperature, the Volta System
powers devices, but the System will not charge,
even if connected to shore power.
-4
-20
Low temperature
fault
Volta System shuts down and does not function
below this temperature.
The values listed in this table represent approximate values that may vary by
system specification, application, and environmental conditions.
Содержание 2023 INTERSTATE 24X
Страница 4: ...2023 Interstate 24X NOTES NOTES...
Страница 6: ...2023 Interstate 24X 1 2 Introduction NOTES NOTES...
Страница 14: ...2023 Interstate 24X 2 8 Safety NOTES NOTES...
Страница 26: ...2023 Interstate 24X 3 12 General Information NOTES NOTES...
Страница 28: ...Floor Plans And Specifications 4 2 2023 Interstate 24X Floor Plans Interstate 24X...
Страница 68: ...2023 Interstate 24X 6 12 Exterior NOTES NOTES...
Страница 78: ...2023 Interstate 24X 7 10 Sprinter Van NOTES NOTES...
Страница 106: ...Maintenance 9 18 2023 Interstate 24X 12 Volt Model Schematic SW...
Страница 107: ...Maintenance 2023 Interstate 24X 9 19 12 Volt Model Schematic SW SW SW SW...
Страница 108: ...Maintenance 9 20 2023 Interstate 24X 12 Volt Model Schematic SW SW SW SW...
Страница 109: ...Maintenance 2023 Interstate 24X 9 21 12 Volt Model Schematic...
Страница 122: ...428 West Pike Street P O Box 629 Jackson Center OH 45334 0629 Phone 937 596 6111 Fax 937 596 6539 www airstream com...