background image

En-3

PREPARATION

OPERATION

• It is possible to make the operation settings for all indoor units or individual units.

Press the “

 PROGRAM/ 

 CLOCK ADJUST” button for

2 seconds or more. The time display on the remote control-
ler will flash.

2

Press the “

 DAY” button and se-

lect the current day.

 appears around the selected

day.

Press the “

” button or “

” button to set the current time.

Press repeatedly to adjust the current time in 1-minute increments. Press and
hold to adjust the current time in 10-minute increments.
* Hold down the “

” button or “

” button to adjust the time quickly.

ex. Monday 10:00 (12-hour display)

Press again the “

  PROGRAM/

 CLOCK ADJUST” button to end.

CLOCK ADJUST

1

3

4

To set the current day and time

CLOCK ADJUST

DAY

 S          M          T          W         T         F         S

AM

(SUN)

(MON)

(TUE)

(WED)

(THU)

(FRI)

(SAT)

Decrement Increment

To select the indoor unit

Press the “

” button to select the indoor unit.

1st indoor unit

2nd indoor unit

8th indoor unit

All indoor units

The   for the selected indoor unit lights, and the operating status is displayed.
* If all indoor units are selected, all of the registered indoor units are controlled at the same time.
* If all indoor units are selected, 

 appears on the Timer and Clock Display.

The initial values for air conditioning when all selection are set to “Stop, COOL, 26 °C (80 °F), HIGH”
regardless of operation setting of the indoor unit.  Accordingly all indoor units will be stopped when it
is operated without pressing the “

” button.

Press the “

 ALL” button to turn on all of the indoor units.

* ALL ON cannot be set within 4 minutes after the start up.
* When ALL ON starts up, the setting of each indoor unit is operated already.

To turn on all indoor units

Press the “ALL 

” button to turn off all of the indoor units.

* ALL OFF cannot be set within 4 minutes after the start up.

To turn off all indoor units

Press the “ON/OFF” button to turn the corresponding indoor unit on or off.

To turn the corresponding indoor unit on or off

This shows the operating status and timer
operation status for each of the indoor units.

 : On

 : Off

 : Selection

 : Timer operation

9374708031-06_OM_en.p65

20/11/2012, 11:40 AM

3

Содержание UTY-CGGG

Страница 1: ...ОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES P N9374708031 06 KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ СОХРАНИТЕ НАСТОЯ...

Страница 2: ...ing consult authorized service personnel for disconnection and installation of this unit Do not touch with wet hands It may cause an electric shock If children may approach the unit take preventive measures so that they cannot reach the unit Do not repair or modify by yourself It may cause a fault or accident Do not use flammable gases near this unit It may cause a fire from leaking gas CAUTION Th...

Страница 3: ...LOCK ADJUST Program Clock Adjust Button 6 ENTER Enter Button 7 ALL All ON Button 8 ALL All OFF Button 9 Start Stop Button 0 Select Button A Fan Control Button B Set Temperature Button C Mode Button D ON OFF Button E Operation Lamp F Day Display G Setting Display H Transmission Display I Operation Lock Display J Temperature Display K ON OFF Display L Timer and Clock Display M Fan Speed Display N Re...

Страница 4: ...or units The for the selected indoor unit lights and the operating status is displayed If all indoor units are selected all of the registered indoor units are controlled at the same time If all indoor units are selected appears on the Timer and Clock Display The initial values for air conditioning when all selection are set to Stop COOL 26 C 80 F HIGH regardless of operation setting of the indoor ...

Страница 5: ...ode is set to Priority on Administrative Indoor Unit the operating mode of other indoor units except Administrative Indoor Unit will be controlled by an Administrative Indoor Unit If the operating mode of Administrative Indoor Unit is set to AUTO AUTO is displayed in addition to the display of current operating mode on other wired remote controllers except Administrative Indoor Unit In this case o...

Страница 6: ...e cancelled Timer setting AM 3 Day of the week setting DAY S M T W T F S ALL SUN MON TUE WED THU FRI SAT Press the DAY button to select the day of the week When select ALL all of the days will be selected WEEKLY TIMER Instructions related to heating are applicable to HEAT PUMP MODELS and HEAT RECOVERY MODELS only The timer function is not available depending on the initial setting Different schedu...

Страница 7: ...the WEEKLY timer does not operate when the COOL or DRY timer is set if a HEAT PUMP MODEL in the air conditioning system is operating in the heating mode 2 Even if the timer operation is set the timer lamp of the indoor unit does not light up The timer lamp is used for wireless remote controller only 3 If the same time is set in Timer 1 to Timer 4 of an indoor unit the timer setting of the smallest...

Страница 8: ...you notice burning smells or the operation lamp flashes immedi ately stop operation turn off the electrical breaker and consult authorized service personnel SPECIFICATIONS MODEL POWER DIMENSIONS WEIGHT HEIGHT WIDTH DEPTH WEIGHT UTY CGG DC 12 V 120 mm 4 3 4 in 120 mm 4 3 4 in 18 mm 23 32 in 200 g 0 44 lbs Setting restriction When is displayed there are functions for which set tings cannot be made S...

Страница 9: ...curs the following display will be shown The air conditioning system must be inspected if error code appears on Time and Clock Display or the operation lamp is flashing Stop air conditioner operation and please consult author ized service personnel Ex 14 error occurs Model code EO EI EC EA Error code ...

Отзывы: