En-3

TIMER OPERATION (ON timer/OFF timer/PROGRAM timer/SLEEP timer)

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

The timer functions cannot be used when this controller is used together with the Remote Controller (Wired type).
A beeping sound is made when a signal is received.

To set the ON/OFF timer

1

2

To set the PROGRAM timer

Adjust the OFF or ON time.

(About 5 seconds later, the
entire display will reappear.)

Select “OFF TIMER” or “ON TIMER”.

1

2

3

4

5

Select “OFF TIMER”.

Adjust the OFF
time.

Select “ON TIMER”.

Adjust the ON time.

(About 5 seconds later, the entire display
will reappear.)

Select “PROGRAM TIMER”.

(Either OFF 

ON or OFF 

 ON

will display.)
(If the ON

 

timer has been se-

lected to operate first, the unit
will stop operating at this point.)

Select “TIMER RESET”.

The air conditioner will return to normal op-
eration.

To cancel the TIMER

To change operating conditions

If you wish to change the operating conditions (ON/OFF, Mode,
Fan Speed, Temperature Setting), after making the time set-
ting, wait until the entire display reappears, then press the ap-
propriate buttons to change to the desired operating condition.

OPERATION

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

To start/stop operation

Start time: The indoor unit’s operation indicator lamp (red) will light up.
Stop time: The indoor unit’s operation indicator lamp (red) will go out.

Operation mode setting

Room temperature setting

Fan speed setting

→ 

 →

 

COOL

 DRY

HEAT 

  FAN

 →

HIGH 

MED

LOW

Vertical air direction adjustment (Swing operation)

Horizontal air direction adjustment (Swing operation)

Press the START/STOP button to start the air conditioner, and then proceed as follows.

NOTES

To set the operation mode

To set the swing operation, press the VERTI-
CAL SWING button (Stop the setting by press-
ing it once again.)

To set the swing operation, press the HORIZON-
TAL SWING button (Stop the setting by press-
ing it once again.)

(1)

• Always use the remote controller’s AIRFLOW DIRECTION button.

Attempting to move the air direction louvers manually could re-
sult in improper operation; in this case, stop operation and re-
start.
The flaps should begin to operate properly again.

• During use of the Cooling mode, do not set the VERTICAL air

direction flap in the 

4

 position for long time, since water vapor

may condense near the outlet port and drops of water may drip
from the air conditioner.

(2)

• The range of swing is relative to the currently set airflow direc-

tion.

• The SWING operation may stop temporarily when the air condi-

tioner’s fan is not operating, or when operating at very low speeds.

<Vertical airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

3

2

2

 to 

4

3

2

 to 

4

4

1

 to 

4

 (All range)

<Horizontal airflow swing operation>
Airflow direction

Range of swing

1

1

 to 

5

 (All range)

2

1

 to 

3

3

2

 to 

4

4

3

 to 

5

5

1

 to 

5

 (All range)

Temperature setting range:
AUTO ............... 18 to 30 

°

C

Heating ............ 16 to 30 

°

C

Cooling/Dry ..... 18 to 30 

°

C

1

2

 

3

 

4

1

2

 

3

 

4

 

5

1

2

3

4

1 2

3

4 5

RESET

 →

OFF TIMER 

ON TIMER

PROGRAM TIMER

 (

OFF 

← 

ON, OFF 

→ 

ON) 

Press the START/STOP button to start the air conditioner, and then proceed as follows.

Press the START/STOP button to start the air conditioner, and then proceed as follows.

Содержание UTB-*V

Страница 1: ...ATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES Remote Control Unit UTB V REMOTE CONTROLLER WIRELESS TYPE English Deutsch Fran ais Esp...

Страница 2: ...erty This mark indicates procedures which if improperly performed might lead to the death or serious injury of the user DANGER Do not attempt to install this controller by yourself This controller con...

Страница 3: ...TION 1 When not using the remote control unit for an extended period remove the batteries to avoid possible leakage and damage to the unit 2 Never mix new and used batteries or batteries of different...

Страница 4: ...MED LOW Vertical air direction adjustment Swing operation Horizontal air direction adjustment Swing operation Press the START STOP button to start the air conditioner and then proceed as follows NOTE...

Страница 5: ...s When two or more air conditioners are installed in a room and the remote control unit is operating an air conditioner other than the one you wish to set change the signal code of the remote control...

Страница 6: ...ith an other kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the...

Страница 7: ...it will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the temperature for a higher setting During Heating operation the unit will temporarily sto...

Отзывы: