En-5

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the electrical breaker is turned off then on again, the
protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

6

6

6

6

NORMAL

FUNCTION

WARNING!

Содержание AU 54TF

Страница 1: ...ED OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES P N9369314018 Indoor Unit AU 20TF AU 25TF AU 30TF AU 36TF AU 45TF AU 54TF Français Español Italiano EλληvIkά Português Русский TM English Deutsch ...

Страница 2: ...ndle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals...

Страница 3: ...ker is installed during the electrical installation Electrical Breaker Fig 5 0 A A 0 Fig 3 Fig 1 Indoor Unit 1 Air Filter 2 Air Intake Grille 3 Air Flow Direction Flaps 4 Indicator Lamps Fig 2 5 SWING Indicator Lamp orange 6 TIMER Indicator Lamp green 7 OPERATION Indicator Lamp red 8 Operating Control Panel Fig 3 9 MANUAL AUTO Button ...

Страница 4: ...in unit control panel To stop operation press the MANUAL AUTO button once again When the air conditioner is operated with the controls on the Main unit it will operate under the same mode as the AUTO mode selected on the re mote control unit However the Heat pump model will follow the operating mode of the other indoor unit The fan speed selected will be AUTO and the thermostat setting will be 23 ...

Страница 5: ... pull the fil ter out Before cleaning the unit be sure to stop the unit and disconnect the power supply Turn off the electrical breaker A fan operates at high speed inside the unit and personal injury could result CAUTION When reinstalling the filter be sure that the hooks at A and B engage correctly into place 4 Clean the air filters Remove the dust from the air filters by vacuuming or washing th...

Страница 6: ...emperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This result...

Страница 7: ...d of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Cooling Heating Priority HEAT PUMP MODEL only If another indoor unit in the same system is already oper ating in the cooling mode or dry mode heating mode settings cannot be...

Страница 8: ...te to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings SPECIFICATIONS Temperature and Humidity ...

Отзывы: