TROUBLESHOOTING

The following conditions may not be breakdowns so check again.

Symptom

Doesn’t operate at all:

The operation mode cannot
be changed:

Poor Cooling (or Heating)
performance:

Set the temperature lower
than the room tempera-
ture and use it:

Items to check

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the main power switch set to the OFF position?

Are you trying to engage in an operation different from the priority state?

Is it in standby state?

Are you trying to change to an operation different from the priority conditions?

Did you adjust the room temperature settings (thermostat) correctly?

Is the air filter dirty?

Are the air conditioner’s inlet port or outlet port blocked?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sunlight to enter?
(Close the curtains.)

In the case of Cooling operation, are there heating apparatus and computers in-
side the room, or are there too many people in the room?

Is the fan speed set to low?

Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.)

See Page



4
4

4

5


4

SPECIFICATIONS

Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor unit.

According to IEC 704-1 and ISO 3744.

In the following situations stop operation immediately and get in touch with authorized
service personnel.

The problem cannot be solved even when the troubleshooting checks have been performed.

The OPERATION indicator lamp (green) is flashing very fast.

The wired remote controller or simple remote controller indicate Er (when connected).

It has burning smell.

AS E07L

AS E09L

AS E12L

AS E14L

230V~50Hz

198 to 264 V

2.20

2.80

3.60

4.50

2.80

3.20

4.10

5.00

34

35

38

43

32

32

34

35

30

30

30

30

275

790

215

9

MODEL

POWER SOURCE

AVAILABLE VOLTAGE RANGE

COOLING CAPACITY

[kW]

HEATING CAPACITY

[kW]

SOUND PRESSURE LEVEL

HIGH

dB (A)

MED

dB (A)

LOW

dB (A)

DIMENSIONS & WEIGHT

HEIGHT

[mm]

WIDTH

[mm]

DEPTH

[mm]

WEIGHT

[kg]

AS A07L

AS A09L

AS A12L

AS A14L

230V~50Hz

198 to 264 V

2.20

2.80

3.60

4.50

2.80

3.20

4.10

5.00

35

36

39

44

33

33

35

37

31

31

31

32

275

790

215

9

MODEL

POWER SOURCE

AVAILABLE VOLTAGE RANGE

COOLING CAPACITY

[kW]

HEATING CAPACITY

[kW]

SOUND PRESSURE LEVEL

HIGH

dB (A)

MED

dB (A)

LOW

dB (A)

DIMENSIONS & WEIGHT

HEIGHT

[mm]

WIDTH

[mm]

DEPTH

[mm]

WEIGHT

[kg]

Содержание AS A07L

Страница 1: ...MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI MANUAL DE INSTRU ES AS E07L AS E09L AS E12L AS E14L AS A07L AS A09L AS A12L AS A14L Compact Wall Mounted Type En...

Страница 2: ...als or plants in the direct path of the air flow Do not direct air flow at fireplaces or heating apparatus Do not block or cover the inlet port and outlet port Do not climb on or place objects on the...

Страница 3: ...5 TIMER Indicator Lamp Orenge It lights on while timer is working 6 Remote Control Signal Receiver This is the place to receive the signals from the remote controller 7 FILTER Indicator Lamp Red It l...

Страница 4: ...button on the operating control panel Operation mode AUTO Fan speed AUTO Setting temperature 23 C When Auto mode cannot be selected it will operate in the same mode as the other indoor unit in the sa...

Страница 5: ...heated Microcomputer controlled automatic defrosting When using the Heating mode under conditions of low outdoor air temperature high humidity frost may form on the outdoor unit resulting in reduced...

Страница 6: ...king sure the 2 lower tabs are returned properly to their holes in the panel 2 The fixing axle of the intake grille is installed on the front panel 3 Lay down the intake grille 2 2 2 2 2 CLEANING AND...

Страница 7: ...orizing filter frame with the 6 hooks at the rear of the air filters 4 Install the 2 air filters and close the intake grille Cleaning body Wash the body with warm water and then dry with a clean and s...

Страница 8: ...d TIMER indicator lamp red are flash ing alternately The OPERATION indicator lamp green and TIMER indicator lamp red are flash ing simultaneously The OPERATION indicator lamp green lights up and the T...

Страница 9: ...nding on the room conditions While high humidity or the room temperature is high See Page 4 4 4 5 4 SPECIFICATIONS Acoustic Noise Information The maximum sound pressure level is less than 70 dB A for...

Отзывы: