En-13
Function details
Function
Function
number
Setting number Default
Details
Filter indicator
interval
11
00
Default
○
Adjust the
fi
lter cleaning interval
noti
fi
cation. If the noti
fi
cation is too early,
change to setting 01. If the noti
fi
cation is
too late, change to setting 02.
01
Longer
02
Shorter
Filter indicator
action
13
00
Enable
○
Enable or disable the
fi
lter indicator.
Setting 02 is for use with a central remote
controller.
01
Disable
02
Display
only on
central
remote
controller
Horizontal swing
air
fl
ow direction
24
00
Default
○
Adjust the horizontal swing air
fl
ow
direction.
(For horizontal swing equipped models)
01
Left half
02
Right half
Cool air
temperature
trigger
30
00
Default
○
Adjust the cool air trigger temperature. To
lower the trigger temperature, use setting
01. To raise the trigger temperature, use
setting 02.
01
Adjust (1)
02
Adjust (2)
Heat air
temperature
trigger
31
00
Default
○
Adjust the heat air trigger temperature.
To lower the trigger temperature by 6
degrees C, use setting 01. To lower
the trigger temperature by 4 degrees
C, use setting 02. To raise the trigger
temperature, use setting 03.
01
Adjust (1)
02
Adjust (2)
03
Adjust (3)
Auto restart
40
00
Enable
Enable or disable automatic system restart
after a power outage.
* Auto restart is an emergency function such
as for power failure etc. Do not start and
stop the indoor unit by this function in
normal operation.
Be sure to operate by the control unit,
converter or external input device.
01
Disable
○
Cool Air
Prevention
43
00
Super low
○
Restrain the cold air
fl
ow with making
the air
fl
ow lower when starting heating
operation. To correspond to the ventilation,
set to 01.
01
Follow the
setting on
the remote
controller
External control
46
00
Start/Stop
○
Allow an external controller to start or stop
the system, or to perform an emergency
stop.
* If an emergency stop is performed from
an external controller, all refrigerant
systems will be disabled.
* If forced stop is set, indoor unit stops by
the input to the external input terminals,
and Start/Stop by a remote controller is
restricted.
01
Emergency
stop
02
Forced
stop
Error report
target
47
00
All
○
Change the target for reporting errors.
Errors can either be reported in all
locations, or only on the central remote
controller.
01
Display only
on central
remote
controller
Fan setting
when cooling
thermostat OFF
49
00
Follow the
setting on
the remote
controller
○
When set to 01, the fan stops when the
thermostat is OFF in cooling operation.
Connection of the wired remote controller
(2-wire type or 3-wire type) and switching
its thermistor are necessary.
01
Stop
7.4.1. Button name and function
OPERATION indicator lamp (Green)
TIMER indicator lamp (Orange)
FILTER indicator lamp (Red)
MANUAL AUTO button
7.4.2. Checking the function settings
Press and hold the “MANUAL AUTO” button on the indoor unit for 3 seconds to check the
function settings. It is necessary to disconnect the power in order to return to normal op-
eration mode.
(1) Indoor unit and refrigerant address indication
Indication pattern
Indicator name
Indication pattern
Indoor unit address
Refrigerant address
OPERATION indica-
tor lamp (Green)
ON
Flash (1.0s ON/1.0s OFF)
TIMER indicator lamp (Orange)
Address: tens place (0.5s ON/0.5s OFF)
FILTER indicator lamp (Red)
Address: ones place (0.5s ON/0.5s OFF)
• Indoor unit address example
(Example) ADDRESS : 24
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator
lamp (Red)
10 sec
1 cycle 12 sec
8 sec
ON
OFF
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
0.5s 0.5s 0.5s 0.5s
ON
OFF
ON
OFF
ON
• Refrigerant address example
(Example) ADDRESS : 30
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
9 sec
1 cycle 12 sec
ON
OFF
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
ON
OFF
ON
OFF
OFF
• Setting details
Function number
Item
Setting number
01
Indoor unit address
00 to 63
02
Refrigeration address
00 to 99
For use with a remote controller, set all rotary switches to 0, and refer to “7.1. Setting the
address” for details.
All switches are set to 0 at the factory.
9367701100-01_IM.indb Sec1:13
9367701100-01_IM.indb Sec1:13
2012-7-12 14:01:39
2012-7-12 14:01:39
Содержание ABHA12GATH
Страница 17: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 01 41 2012 7 12 14 01 41...
Страница 33: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 01 50 2012 7 12 14 01 50...
Страница 49: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 01 59 2012 7 12 14 01 59...
Страница 65: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 02 07 2012 7 12 14 02 07...
Страница 81: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 02 16 2012 7 12 14 02 16...
Страница 97: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 02 25 2012 7 12 14 02 25...
Страница 113: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 02 35 2012 7 12 14 02 35...
Страница 129: ...9367701100 01_IM indb Sec1 16 9367701100 01_IM indb Sec1 16 2012 7 12 14 02 44 2012 7 12 14 02 44...