Mounting the De vices
Hardw are Insta llatio n Guide
7-2 Airspan
Networks
Inc.
02030311-10
Figure
7-1: Mounting holes on BSR bottom panel
To prevent radio interference, each BSR requires a minimum of 1-metre horizontal
separation between adjacent BSRs (see Figure 7-2).
1 Metre min.
Figure
7-2: Minimum separation between mounted BSRs
Warning:
To avoid RF interference between BSRs operating in the
700 MHz
where four BSRs are installed at a Base Station (and in addition to 1-meter
horizontal separation), a minimum 1-meter
vertical
separation must be
provided between the two pairs of BSR antennas: one pair operating in the
lower frequencies (i.e. 711.5 and 714.5 for 1 Msps mode; 712 and 714 for 1.33
Msps mode) and the other pair operating in the upper frequencies
(i.e. 741.5 and 744.5 for 1 Msps mode; 742 and 744 for 1.33 Msps mode).
Mounting holes