11. Verify the gland size as shown below.
Table 9: Recommended Gland Size
Diameter
Recommended Gland Size
From 6.6min to 7.95 Max
“Φ8”
From 7.5min to 8.95 Max
“Φ9”
From 8.6min to 9.95 Max
“Φ10”
From 10.3min to 11.03 Max
“Φ11.5”
Note:
The gland size is written on the edge of the gland.
Figure 22: Gland Size on Edge
Note:
The tolerances of the diameter should be taken into account to make sure it is always
within the specified range.
12. Place the tightening cone onto the split rubber gland.
Figure 23: Place Tightening Cone on Split Gland
13. Secure the Gland nut on to the body forcing the seal to compress around the power cable,
then tighten the Gland nut with a 21mm wrench.
Caution:
Do not over tighten the Gland nut. The Gland nut should be tightened to a torque of
no
more than 2.5-3.0 Nm (1.84 – 2.21 ft-lb) max.
Figure 24: Tighten Gland Nut