AirSpeed 1050 B3 Installation Guide
DUG01593
Airspan Commercial and Internal Use
24
Connect and Manage Cables
4.3 Connecting the Ground Cable
Connect the ground lug with the ground cable (not supplied) to the M6 threaded bolt on the bracket
assembled on the unit clearly marked with the universal ground symbol.
Note:
Cutting the ground cable to the required length and crimping the grounding lug is performed
by the Installer.
The cable should be grounded according to international or local standards.
Figure 9: Ground Connection
4.4 TX Power Monitoring Port
There is the option to monitor TX power via the available monitoring ports (SMA Jack B/H) found on the
bottom of the AirSpeed 1050 B3 unit. See Figure 4: AirSpeed 1050 B3 Bottom
4.5 Cable Connection
The following explains the general instructions on how to connect a power cable (AC) and the SFP &
Copper Ethernet cables to the AirSpeed 1050 B3 unit.
Danger:
Hazardous voltage!
Before working, ensure that the power is removed from the power
connection cables. When the system is powered on,
do not touch the power terminals
.
Airspan recommends the following outdoor Power cable requirements
– Cable, 3C, SJOOW, 18AWG,
Stranded, Outdoor.
Table 10: Outdoor Power Cable Requirements
Outdoor Power Cable
18 AWG
Jacket 300V
Water Resistant
UV Resistant