TROBULE SHOOTING

ACCESSORIES

NOT

WORKING

POOR

COOLING

TROUBLE 

CHECK

REMEDY

● Power plug correctly connected

● Connect plug correctly

● POWER button 

“OFF”

● Press POWER button to 

“ON”

● Blown fuse in electric panel

● Replace fuse

● Fuse (supply) blown

● Exchange fuse in board

● Breaker on switch board

● Check load capacity and reset

tripped

● Ambient temp. too high

● Use only below 45℃

(over 45℃) (HSC-3500 : 40℃)

(HSC-3500 : 40℃)

● Filter blocked with dust

● Clean Filter

● Dust in heat exchanger

● Clean heat exchanger

● Obstacle against inlet side

● Remove and allow 50cm.clearance

● Ambient temp. too high

● Use only below 45℃

(over 45℃) (HSC-3500 : 40℃)

(HSC-3500 : 40℃)

MODEL

ITEM

COLD 

AIR

OUTLET

HOT 

AIR

EXHAUST

DUCT

OPTION

OPTION

Diam.
125mm

DRAWING

HSC-2500/HSC-3500

DUCT COVER

(FINISHING COLLAR)

DAMPER BASE

(FLOW CONTROL FLAP)

ALUMINIUM FILTER

CASSETTE

ALUMINIUM FILTER

CASSETTE

REDUCER

REDUCES EXH.
DUCT FROM
43cm to 30cm

0.5m

3m

Содержание HSC-2500

Страница 1: ...and follow them at all times This Air Conditioner is specified for use on a 220 240Va c 60Hz single phase power supply You must check that the local electricity supply is the same and have the appropr...

Страница 2: ...CTIONS DESCRIPTION Front View Back View Control Panel OPERATING INSTRUCTIONS On Off Operation Selection of Area Room or Spot Cooling Temperature Control Off Timer Error and Warning Indicators CLEANING...

Страница 3: ...o not remove plug by pulling cable or with wet hands Risk of fire and electric shock Before cleaning remove plug from socket Otherwise risk of electric shock Do not place anything on top of the machin...

Страница 4: ...220 240Va c 50Hz It will be applied and adjusted as per customer s request You must supply power as per it s requirement only once it is adjusted CAUTION Do not place cooler on uneven unstable or inc...

Страница 5: ...CASTERS FRONT LOCKABLE ELECTRIC PANEL ACCESS BY AUTHORISED SERVICE PERSONNEL ONLY POWER PLUG CONDENSER OUTLET HOT AIR EVAPORATOR FILTER AMBIENT AIR INTAKE CONDENSER FILTER WATER LEVEL INDICATOR TO CHE...

Страница 6: ...he LED is On the displayed temperature is for Room temp If the LED is Off the displayed temperature is for spot temp Comp When the compressor is operating the LED is On Error Error signal E1 High Pres...

Страница 7: ...tically To STOP the unit press the POWER button once again 2 To change fan speed press the Low button 3 If you wish to operate on fan only press the COOL button To resume cooling press the COOL button...

Страница 8: ...oom select Area Room For targeted cooling of machinery servers or people etc select Spot Cooling 1 IF YOU WANT TO DISPLAY ROOM TEMPERATURE PUSH COOL AND BUTTON SIMULTANEOUSLY FOR THREE SECONDS 2 IF YO...

Страница 9: ...ither or button the setting temperature is changed 3 The display showing the set temperature will blink 3 times 4 Limits of Room Spot and Setting temperatures Room Spot Temp Setting range 0 50 1 30 Co...

Страница 10: ...u press the button you will increase the time to off period by 30mins up to 10 hours and 1 hour thereafter up to 24 hours The display will show 5 for 30min and 1 for an hour e g One and a half hours w...

Страница 11: ...itioned correctly the LED Align Drain Tank light will be on 3 HIGH PRESSURE E1 is displayed and the Error LED will be on when the pressure of the compressor is too high and the high pressure switch is...

Страница 12: ...d air 3 Clean evaporator and condenser units with a vacuum cleaner or compressed air MAINTENANCE 1 After cleaning completely dry the inside of the unit by operating on Fan Mode only for 3 to 4 hours 2...

Страница 13: ...too high Use only below 45 over 45 HSC 3500 40 HSC 3500 40 Filter blocked with dust Clean Filter Dust in heat exchanger Clean heat exchanger Obstacle against inlet side Remove and allow 50cm clearance...

Страница 14: ...HS SC C 2 25 50 00 0 H HS SC C 3 35 50 00 0 Cooling Capacity Power Supply 220 240Va c 50Hz 1Ph Dimensions mm 490 X 600 X 1 303 Weight Kg 86 90 Evaporator Air Flow ft3 m m3 m 459 11 13 565 14 16 Noise...

Страница 15: ...uring the period of warranty subject to the following warranty conditions 1 The warranty period is 12 months from the date of first purchase 2 If the problem has been caused by customer error or misus...

Страница 16: ...Designs and specifications of products are subject to change without prior notice for the improvement of products...

Отзывы: