background image

4

SAFETY NOTICE

GENERAL ADVICE BEFORE USE

·Ensure the safety of the location in which Heat Pump is to be used.
·Ensure the floor or ground is smooth and sound.
·Ensure you allow at least 20inch air space all around the Heat Pump.
·When in position LOCK the casters to prevent rolling.
·Never use the Heat Pump at more than 2。incline.
·If you use condensate pump, connect with housing in the power box.(Electric panel)

FOR MAXIMUM EFFICIENCY

·In airtight areas use vertical exhaust into ceiling.
·If possible locate exhaust outlet through a window or door to outside.
·Exhaust ducting should be no longer than 6.6 ft. for maximum efficiency.
·Ensure correct electricity supply.

CAUTION

Do not place Heat Pump on uneven, unstable or inclined surface.
(This could cause malfunction)

When storing the Heat Pump, ensure that it is kept in a dry, cool place.
(To prevent corrosion and malfunction)

If not being used for some time or if lightening is present, always unplug 
from power. (To prevent risk of electric shock, short circuit or fire)

Do not spray water on to the Heat Pump nor use solvents such as benzene, 
thinner or alcohol for cleaning.
(There is a risk of electric shock and / or short circuit)

Designed for indoor usage.

Содержание AHSC-18

Страница 1: ...m at all times The Heat Pump is specified for use on a 115V 60Hz 1Ph single phase power supply You must check that the local electricity supply is the same and have the appropriate plug fitted by a qu...

Страница 2: ...ONS OPERATION Running Stop SELECTION of AREA ROOM or SPOT COOLING or HEATING ECONOMIC MODE COOLING or HEATING TEMPERATURE CONTROL OPERATION HOW TO SET THE OFF TIMER ERROR and WARNING INDICATORS FIRE A...

Страница 3: ...t Otherwise risk of electric shock Do not place anything on top of the machine This could cause electric shock malfunction or injury Do not use an extension cord Risk of fire and or electric shock Ens...

Страница 4: ...cate exhaust outlet through a window or door to outside Exhaust ducting should be no longer than 6 6 ft for maximum efficiency Ensure correct electricity supply CAUTION Do not place Heat Pump on uneve...

Страница 5: ...ONT VIEW BACK VIEW LOUVER CONDENSER OUTLET DIGITAL CONTROLLER CASTERS 4 FRONT LOCKABLE CASTERS 4 REAR NO LOCK SERVICE COVER 1 CONDENSER FILTER EVAPORATOR FILTER SERVICE COVER 2 FIRE ALARM CONNECTION P...

Страница 6: ...e is for Room temp If the LED is Off the displayed temperature is for spot temp Comp When the compressor is operating the LED is On Error Error signal E1 High Pressure E2 Low Pressure E3 Sensor AF ANT...

Страница 7: ...s the POWER button once again 2 If you wish to operate on heating press HEAT button 3 If you wish to operate on fan only press the COOL button To resume cooling press the COOL button again Note There...

Страница 8: ...ooling of machinery servers or people etc select Spot Cooling or Heating 2 If you want to change temperature unit push and button simultaneously for three seconds If the compressor operation is stop i...

Страница 9: ...3 The display showing the set temperature will blink 3 times COOLING MODE 4 Display range Setting range HEATING MODE 9 COOLING or HEATING TEMPERATURE CONTROL OPERATION Cooling operates when Room Spot...

Страница 10: ...you press the button you will increase the time to off period by 30min up to 10 hours and 1 hour thereafter up to 24 hours The display will show 0 5 for 30min and 1 0 for an hour e g One and half hou...

Страница 11: ...ght will be on 3 HIGH PRESSURE E1 is displayed and the Error LED will be on when the pressure of the compressor is too high and the high pressure switch is open 4 LOW PRESSURE E2 is displayed and the...

Страница 12: ...26 AWG for a solid wire or 16 AWG to 22 AWG for a stranded wire with ring terminal for 5 stud size 3 Connect the end of the error signal wire to ER1 and ER2 and the other end to the compatible with v...

Страница 13: ...ISPLAY CONDITIONS NO Error Display Error condition Error LAMP Error Signal Output 1 E1 High pressure Error ON 2 E2 Low pressure Error ON 3 E3 Sensor Problem Error ON 4 FU Water Full Water Full ON 5 AF...

Страница 14: ...d air 3 Clean evaporator and condenser units with a vacuum cleaner or compressed air MAINTENANCE 1 After cleaning completely dry the inside of the unit by operating on Fan Mode only for 3 to 4 hours 2...

Страница 15: ...k load capacity and reset tripped Ambient temp too high Use only below Cooling 113 Heating 81 Cooling over 113 Heating over 81 Filter blocked with dust Clean Filter Dust in heat exchanger Clean heat e...

Страница 16: ...00 5 42 Cooling current Power consumtion Heating current Power consumtion Cooling Capacity Heating Capacity AHSC 18 Power Supply 115V 60Hz 1Ph inch 19 5 X 26 6 X 52 2 Weight lb 210 Evaporator Air Flow...

Страница 17: ...iod of warranty subject to the following warranty conditions 1 The warranty period is 12 months from the date of first purchase 2 If the problem has been caused by customer error or misuse abuse or da...

Страница 18: ...18 MEMO...

Страница 19: ...19 MEMO...

Страница 20: ...02 5519 E mail airrex hdtek com Website www airrex co kr Designs and specifications of products are subject to change without prior notice for the improvement of products USA DISTRIBUTOR AIRREX USA P...

Отзывы: