background image

4

SAFETY INSTRUCTIONS

GENERAL ADVICE BEFORE USE

Do not place this unit on uneven, unstable or inclined surface.
(This could cause malfunction)

When storing this unit, keep it in a dry, cool place.
(To prevent corrosion and malfunction)

If not being used for some time or if lightening is present, always disconnect from power.
(To prevent risk of electric shock, short circuit or fire)

Do not spray water onto this unit nor use solvents 
such as benzene, thinner or alcohol for cleaning.
(There is a risk of electric shock and / or short circuit)

Designed for indoor use.

Waste electrical and electronic products must be disposed separately from normal household waste.
When you dispose of such products, please recycle where facilities exist. Follow the guidance of 
your local authority and/or ask the shop where you purchased the product.

Waste electrical and electronic products must be disposed separately from normal household waste.
When you dispose of such products, please recycle where facilities exist. Follow the guidance of 
your local authority and/or ask the shop where you purchased the product.

* Ensure the safety of the location in which the unit is to be used.  

* Ensure the floor or ground is smooth and round.

* Ensure you allow at least 20 inch air space all around the unit. 

* When in position LOCK the casters to prevent rolling.       

* Never use the unit at more than 2˚ incline.            

* If you use condensate pump connect with housing in the power box. (Electric panel)

* You have to connect supply cord at least standard

   If the supply cable is damaged, it must be replaced by the manufacturer, 

   its service agent or similarly qualified person in order to avoid a hazard.

FOR MAXIMUM EFFICIENCY  

      

     

* In airtight areas use vertical exhaust into ceiling.                        

* If possible locate exhaust outlet through a window or door to outside.

* Exhaust ducting should be no longer than 6.6 ft. for maximum efficiency.

* Ensure correct electricity supply.

 

CAUTION

Содержание ADH-100

Страница 1: ...d electrician We have a policy of continual improving on our products The contents features and specifications in this manual are therefore subject to change without notice The warranty form is on the...

Страница 2: ...follow all instructions There are two sections to these instructions WARNING and CAUTION 3 4 4 5 6 7 8 9 10 11 12 16 SAFETY INSTRUCTIONS GENERAL ADVICE BEFORE USE EXTERIOR DESCRIPTION SPECIFICATIONS C...

Страница 3: ...e may occur Unlock the casters and push the unit to a flat level surface and set the caster brakes to the locked position If the power cord or plug is damaged repair should only be performed by qualif...

Страница 4: ...nic products must be disposed separately from normal household waste When you dispose of such products please recycle where facilities exist Follow the guidance of your local authority and or ask the...

Страница 5: ...EXTERIOR DESCRIPTION FRONT VIEW BACK SIDE VIEW AIR INLET CASTER FRONT LOCKABLE CASTER REAR 10 BACK HANDLE EVAPORATOR FILTER AIR OUTLET POWER CORD DIGITAL CONTROLLER CONDENSED WATER OUTLET PUMP BUTTON...

Страница 6: ...nsions WxDxH inch 19 9 x 21 8 x 39 2 Weight lb 132 Air Filter Vinyl Chloride Mesh Catridge Safety Device High pressure switch Low pressure switch 3 min delay timer Fan motor protection Automatic full...

Страница 7: ...intervals are 0mins up to 10 hours and then 1 hour between 10 and 24 hours Defrost When the temperature of the evaporator is below 4 the defrost valve operate and Defrost led is on Comp When the compr...

Страница 8: ...ou will increase the time to off period by 30mins up to 10 hours and 1 hour up to 24 hours The display will show 5 for 30min and 1 for an hour One and a half hours will show 1 5 2 When you have finish...

Страница 9: ...e setting humidity The display showing the set humidity will blink 3 times When you push either or button the setting humidity is changed The display showing the setting humidity will blink 3 times Se...

Страница 10: ...Humidity sensor High pressure Blocked air filter Blocked kinked exhaust duct Ambient temperature is too high Ensure exhaust duct is not blocked kinked Do not use the air conditioner if ambient temper...

Страница 11: ...r cable correctly connected Connect cable correctly Power button OFF Press POWER button to ON Fuse supply blown Exchange fuse in board Breaker on switch board tripped Check load capacity and reset Amb...

Страница 12: ...case and pull towards you 2 Clean the filters with water or compressed air 3 Clean heat exchanger unit with a vacuum cleaner or compressed air 1 Turn OFF at control panel remove plug from socket Coil...

Страница 13: ...13 MEMO...

Страница 14: ...14 MEMO...

Страница 15: ...15 MEMO...

Страница 16: ...airs will be charged for 2 This warranty applies to your country 3 Proof and date of purchase must be supplied 4 Please complete the details below and keep this warranty in a safe place 5 All transpor...

Отзывы: