AIRORLITE 50289-BA-8-PA Скачать руководство пользователя страница 4

50289

BA

8

PA

 

4

BASIC

 

CONNECTION

 

DIAGRAM

 

KEY

 

 

ID

 

Item

 

1

 

Item

 

2

 

W1

 

Downlink

 

Power

 

Amp

 

Output

 

Downlink

 

Radiator

 

W5

 

Duplexer

 

Antenna

 

Port

 

"Off

 

the

 

Air"

 

Antenna

 

W6

 

Duplexer

 

Downlink

 

Downlink

 

8

 

Way

 

Splitter

 

W7

 

Duplexer

 

Uplink

 

Uplink

 

Power

 

Amplifier

 

Output

 

W9

 

Uplink

 

8

 

Way

 

Splitter

 

Uplink

 

Radiator

 

W10

 

Uplink

 

8

 

Way

 

Combiner

 

Uplink

 

Power

 

Amplifier

 

Input

 

W14

 

Downlink

 

8

 

Way

 

Combiner

 

Downlink

 

Power

 

Amplifier

 

Input

 

 
 
 

The

 

Basic

 

Connection

 

Diagram

 

shown

 

above,

 

is

 

the

 

proper

 

way

 

the

 

BDA

 

should

 

be

 

connected

 

and

 

once

 

up

 

and

 

running,

 

require

 

minimal

 

to

 

none

 

manual

 

configuration.

  

Connections

 

between

 

cabinets

 

are

 

made

 

through

 

N

Bulkhead

 

connectors

 

located

 

on

 

the

 

top

 

of

 

each

 

cabinet.

  

All

 

programming

 

and

 

adjusting

 

is

 

done

 

through

 

the

 

software

 

and

 

this

 

manual

 

primarily

 

deals

 

with

 

this

 

topic.

 

 

The

 

computer

 

running

 

the

 

software

 

is

 

connected

 

via

 

an

 

RS232

 

serial

 

cable

 

to

 

each

 

channel

 

card

 

in

 

the

 

manner

 

shown

 

below.

 

 
 

 

Содержание 50289-BA-8-PA

Страница 1: ...ANY EQUIPMENT REPAIRED OR ALTERED BY PERSONS NOT AUTHORIZED BY AIRORLITE OR NOT IN ACCORDANCE WITH INSTRUCTIONS FURNISHED BY AIRORLITE AIRORLITE IS NOT RESPONSIBLE FOR EQUIPMENT RENDERED DEFECTIVE AS...

Страница 2: ...in either direction Maximum Passband Ripple Across Full Band 2 dB Maximum Passband Ripple Across any 100 kHz segment 0 1 dB Amplifier Input Ports no damage 0 dBm Propagation Delay 32 microseconds maxi...

Страница 3: ...50289 BA 8 PA 3 Connection Chart BASIC CONNECTION DIAGRAM...

Страница 4: ...W14 Downlink 8 Way Combiner Downlink Power Amplifier Input The Basic Connection Diagram shown above is the proper way the BDA should be connected and once up and running require minimal to none manual...

Страница 5: ...EN Below is the main working screen used to configure the channel card settings The primary fields addressed are Communication Connection Time Out Timer Mode Setting Key On Delay Key Off Delay Attenua...

Страница 6: ...hecks the condition of its communication with the intended channel Each message is acknowledged and displayed in the message box at the bottom of the screen If the software does not receive a response...

Страница 7: ...n be up set from 1 second to 99 seconds 1 second intervals The time out duration can be disabled by setting it to 00 when disabled the channel will key continuously with the presence of a received sig...

Страница 8: ...tting In the carrier detect mode CD the channel is keyed only when the incoming signal strength is above the factory set threshold level Normal operation will be in CD mode continuous mode is normally...

Страница 9: ...ay duration can be up set from 0 to 99 milliseconds 1 millisecond intervals SETTING KEY ON DELAY To set a time out time click on the text box Key On Delay and enter the desired delay up to 99 millisec...

Страница 10: ...ay duration can be up set from 0 to 99 milliseconds 1 millisecond intervals SETTING KEY OFF DELAY To set a time out time click on the text box Key Off Delay and enter the desired delay up to 99 millis...

Страница 11: ...nuator can be set 0 to 15dB in 1dB steps SETTING ATTENUATION To set Attenuation click the function window Attenuation on the main screen Click on the scroll bar next to the text box a scroll down list...

Страница 12: ...wnlink frequencies The user can program any card to any of these 8 specified frequencies To set frequency click the function window Frequency Setting on the main screen Click on the scroll bar next to...

Страница 13: ...nel Note designated limits assume a 2 meter separation distance the device is compliant at 50 cm Note This equipment has been tested and found to comply with the limits for a Class A digital device pu...

Отзывы: