LIMITED WARRANTY FOR INTERZON EQUIPMENT 

This warranty is subject to the following conditions.

A new product is warranted to be free from defects and/or workmanship for a period of 3 years. If the product 

registration form is submitted to Interzon within ten (10) days after the installation is completed, the warranty 

shall begin on that date.

The product warranty covers the repair or replacement of defective parts, labor charges according the recommended 

hours by Interzon, and a maximum travel charge of 175 miles round trip.

The product must be installed according to the specifications described in the product Installation and Service Guide. 

Circumstances which can void the warranty include, but are not limited to:

1. If the installation of the generator does not follow all requirements stated in the product Installation and  

Service Guide;

2. If the airflow or pressure are not kept to the product specifications;

3. If any foreign matter such as water or other cleaning agents are sprayed into the generator;

4. If the regular inspection and cleaning maintenance for the product are not followed;

5. Any other damage resulting from accident, alteration, misuse, if the serial number is removed or defaced, or any 

other external influences.

A spare part is warranted to be free from defects and/or workmanship for a period of ninety (90) days from the date 

of its installation. The warranty covers only the repair or replacement of the part itself and does not include any 

labor, travel or other incidental charges related to its replacement.

Check that the shipment includes the components below and that there is no visible damage. Remove the service hatch 

and carefully inspect the CGC ozone cells that none of the glass tubes are damaged. Any damage must be reported 

immediately to the distributor or manufacturer. Read this guide completely before beginning the installation.

 1.  CHECK  PRODUCT

1 x AirMaid® Ozone Generator

  1.  Check Product........................................................ 4
  2.  Planning Your Installation .................................. 5
  3.  Sample Installations ............................................. 7
  4.  Installation Detail .................................................. 8
  5.  Electrical Installation ......................................... 10
 6.  Commissioning .................................................... 11

  7.  The AirMaid Alarm Panel .................................. 13
  8.  Service and maintenance................................. 16
 9.  Specifications ....................................................... 17
 10.  Troubleshooting .................................................. 18
 11.  Product  Registration .......................................... 19

1 x AirMaid® Alarm Panel

+

Содержание 10000V

Страница 1: ...stallation Operation and Maintenance AirMaid V Series Ozone Cleaning System NORTH AMERICAN 120 VAC 2000V 5000V 10000V 20000V AirMaid ozone cleaning system Innovative Air Treatment Revised February 14...

Страница 2: ...2...

Страница 3: ...and extraction ducts must be installed by qualified per sonnel in compliance with all manufacturer instructions as well as local state and national building electric and fire safety codes Troubleshoo...

Страница 4: ...generator 4 If the regular inspection and cleaning maintenance for the product are not followed 5 Any other damage resulting from accident alteration misuse if the serial number is removed or defaced...

Страница 5: ...EU3 shall be in stalled Filter box inlet air can be taken from above an inner ceiling from an adjoining space or from the outdoors with precautions taken to prevent the entry of moisture If taken fro...

Страница 6: ...e point of exhaust With this in mind we recommend a minimum dwell time of 2 seconds to obtain good results for the reduction of cooking odor However please keep in mind that a longer dwell time will o...

Страница 7: ...THIS TYPICAL INSTALLATION DETAIL IS FOR REFERENCE ONLY THE PROJECT SPECIFIC INSTALLATION MUST MEET ALL LOCAL STATE AND NATIONAL BUILDING ELE CTRIC AND FIRE SAFETY CODES LAYOUT SHOWN IS COMPLIANT WITH...

Страница 8: ...nlet and outlet pipes Multiple duct connections are unnecessary As long as you have sufficient static pressure to obtain the correct bleed airflow through the generator then multiple connections to th...

Страница 9: ...ownward Never screw or drill through the generator Hang using 5 16 in threaded rods and anchor these with nuts on each side of the respective bracket 2 Fasten the outlet pipe 6 between the ozone gener...

Страница 10: ...eir own alarm panel Electrical Connection The installation must be performed by an authorized electrician and follow national standards and regulations The fan interlock displayed on the diagram below...

Страница 11: ...if you choose not to accept their factory defaults ALARM DELAY 5 minutes INSP CLEAN 12 months 4 Perform Functional Check Of CGC Cell s 4 1 Ensure the ventilation system of the facility is running norm...

Страница 12: ...on with Interzon 7 1 Register the generator online within 10 days installation at www interzon com Registering the AirMaid generator installation is important to both the reseller and end customer Fir...

Страница 13: ...em with the static pressure Kitchen hood filters might not be installed properly or a fire damper or control damper if installed is not open Perform troubleshooting following the flow chart in section...

Страница 14: ...the delay is set to 5 minutes in order to prevent an alarm in case of a temporary disruption SET INSP CLEAN Service and maintenance interval in months After this time period the alarm panel will blin...

Страница 15: ...if cleaning is performed before the timed reminder is displayed 1 Number of registered events 2 Cause A Alarm C Calibration P Pressure Fault N Not Connected generator not detected 3 Event Duration 4...

Страница 16: ...the glass electrodes of the ozone cells are not damaged or cracked A proper ozone cell should be clean and free from any mechanical damage according to the picture to the right above Caution The glas...

Страница 17: ...ired negative pressure is established The thermal switch prevents the ozone generator from overheating The main switch is supplied with a thermal overload protection of 4A Facts about Ozone Ozone is a...

Страница 18: ...or Troubleshooting completed Turn off the main power switch and remove the service hatch on the bottom of the generator Are all electrodes of the CGC Cell s free from damage Please perform the steps i...

Страница 19: ...one E mail Product Identification Model AirMaid 2000V AirMaid 5000V AirMaid 10000V AirMaid 20000V Product Serial No Date of installation mm dd yyyy From Commissioning Generator Airflow cfm Generator P...

Страница 20: ...6 8 544 444 39 SE 183 62 T by Stockholm E mail info interzon com Sweden Internet www interzon com Reproduction modification or translation without a prior written consent is forbidden with the excepti...

Отзывы: