SP-101
Smart energy plug in switch
User Manual
Страница 1: ...SP 101 Smart energy plug in switch User Manual ...
Страница 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...
Страница 3: ...hat to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or m...
Страница 4: ...e SP 101 User Manual iii Table of Contents 1 Overview 1 1 1 Adding to Z WaveTM Network 1 1 2 LED Indication 3 1 3 Choosing a Suitable Location 3 1 4 Installation 3 1 5 Programming 4 1 6 Troubleshooting 10 1 7 Specifications 11 ...
Страница 5: ...t can learn with Secured controller Its functionality and supported command classes is identical when included as a secure and non secure device This plug in ON OFF switch is able to detect instance wattage 3000W 230Vac 13Ampere and overload current 14 5A with resistive load of connected lights or appliances When detecting overload state the Switch will be disabled and its On Off button will be lo...
Страница 6: ...e a node ID to the Switch LED 2 second on 2 second off Inclusion 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing On Off button three times within 2 seconds will enter inclusion mode Exclusion 1 Put your Z Wave controller into exclusion mode by following the instructions provided by the controller manufacturer 2 Press...
Страница 7: ...hts up whereas Off LED is off No node ID Under normal operation when the Switch has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When Plug is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the Switch is dis...
Страница 8: ...nd Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF 1 5 1 2 BASIC_SET SWITCH_BINARY_SET Upon receipt of the following commands from a Z Wave Controller the load attached to the Switch will turn on or off Command Class Basic Bas...
Страница 9: ...t When Plug detects the current is more than 14 5A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 1 5 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load po...
Страница 10: ...3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 1 5 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 1 5 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Met...
Страница 11: ...er Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It means that the load power factor is 0 99 1 5 3 Z Wave s Conf...
Страница 12: ... Consumption KW h every 1 hour to Group1 node The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 1 5 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold value if the setting value is 1300 when the load current of Relay1 over this value Plug will send current meter report to war...
Страница 13: ...rease to zero it will switch to off automatically However if Auto off timer is set as 0 the auto off function will be disabled The default setting is 0 1 5 3 9 RF off command mode Whenever a switch off command BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF is received it could be interpreted as 4 variety of commands 1 5 3 9 1 Switch Off It switches to OFF state The default setting is Switch Off 1 5 3 ...
Страница 14: ...OMMAND_CLASS_ALARM COMMAND_CLASS_PROTECTION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 1 6 Troubleshooting Symptom Cause of Failure Recommendation The Switch not working and LED off 1 The Switch is not plugged into the electrical outlet properly 2 The Switch break down 1 Check power connections 2 Don t open up the Switch and send it for repair The Switch LED illuminating but cannot control the ON OFF Swi...
Страница 15: ... Ampere 13A Resistive load Socket Type Germany type France type UK type US type Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU 908 4MHz 916 0MHz USA Specifications are subject to change and improvement without notice OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 ...