Startup (Internal Combustion Models)
18
3A4102C
8.
Hold gun against grounded metal
flushing pail. Trigger gun and increase
fluid pressure slowly until pump runs
smoothly. Release trigger and allow
sprayer to build pressure. Engage
trigger lock.
9.
Inspect for leaks. If leaks occur, turn
sprayer OFF immediately. Perform
Tighten leaky fittings. Repeat
Startup
procedure steps 2-8. If no leaks,
continue to trigger gun until system is
thoroughly flushed.
10. Place siphon tube in paint pail.
11. Trigger gun again into flushing fluid pail
until paint appears.
12. Assemble Tip and Guard, page 21.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.
FLUSH
WLD
ti9695a
ti18248a