Repair
3A0413B
11
Repair
Disassemble
NOTE:
If replacing only the needle and seat,
steps 4 and 5 are not required. However,
removing them allows you to clean the gun
more thoroughly.
1.
Relieve Pressure
, page 8.
2.
Disconnect fluid hose (A). Remove tip
guard (30). Unscrew spring screw (21)
about 1/4 in. (7 mm) to release spring
tension.
3.
Unscrew valve seat (2a). Remove
gasket (2b).
4.
Remove one e-clip (27). Push out pin
(18). Remove screw (29), pivot pin (28),
and trigger (25).
5.
Remove screws (24).
6.
Loosen setscrews (15). Pull fluid
housing (22) away from gun body (1).
To avoid personal injury, always read all
warnings in this manual, and the
equipment manual, before performing any
repairs on the gun.
ti29183a
ti15236a
2a
2b
28
25
27
29
18
ti15238a
24
22
1
15
ti15239a
Содержание 24E365 600 Series
Страница 17: ...Notes 3A0413B 17 Notes...