AirKing ECQ Series Скачать руководство пользователя страница 3

www.airkinglimited.com

6728061 Rev. C 1-15

3 of 12

CAUTION: 

ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR 

ROOF CAP.

SECTION 7

Setting the speed control

1.  Your range hood is equipped with a speed control that allows 

the hood to run continuously at the preset CFM level. To set 

the CFM level, move the rotary dial located inside the wire 

compartment to the desired CFM.

2.  Locate the rocker switch labeled "ASHRAE 62.2" on the 

speed control cover and make sure it is in the ON position. To 

turn the continuous speed function off, set the switch to the 

OFF position.

WARNING:

 SWITCHING THE CONTINUOUS SPEED 

ROCKER SWITCH TO THE OFF POSITION DOES NOT TURN THE 

MAIN POWER TO THE HOOD OFF.

SECTION 8

Finishing the Installation

1.  Reinstall the bottom cover removed in Section 1 using the 4 screws to secure it in place.

2.  Reinstall the filters by fitting them into the channel on either side of the hood and 

pushing upwards on them until they are secured in place 

(Figure 9).

3.  Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins 

on the lamp base to the socket of the lamp holder and turning the lamp body clockwise 

until the lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt 

maximum type C7 (candelabra base) night light (not included) into the side lamp holder 

and reinstall the lamp cover by squeezing the cover’s sides and fitting them into the slots 

on the hood.

4.  Turn switches to the “OFF” position and restore power. Test that the light and the fan are 

operating properly.

5.  If there is any vibration noise, check for the source and try to tighten fasteners or adjust 

the tape to make a tighter connection or seal.

SECTION 9

Controls

Your Range Hood is equipped with two rotary switches with one controlling the lighting and 

the other controlling the exhaust fan. The light switch has three positions, Main Light ( 

 ), 

Night Light ( 

 ), and OFF ( 

 ). The fan switch has three positions, High, Low, and OFF.

SECTION 4

Installing the Range Hood

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE 

STARTING INSTALLATION.

NOTE:

 If installing into existing construction and you will not have access to the ductwork 

once the hood is in place, make ducting connections at this point. Refer to the Ducting 
Section for instructions.

1.  Install the 4 mounting screws at the previously marked locations. Leave approximately 1/8" 

clearance. Slide the hood in place through the keyhole slots and align the front of the hood 
so that it is flush with the front of the cabinets. Tighten all screws securely 

(Figure 6).

CAUTION:

 

DO NOT INSTALL CLOSER THAN 20 INCHES ABOVE COOKING SURFACE.

SECTION 5

Wiring

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE 

WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE 

UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE 

SERVICES OF A QUALIFIED ELECTRICIAN.

1.  Connect the two loose White wires from the range hood to the White wire from the 

supply, and the loose Black wire from the range hood to the Black wire of the supply. 
Connect the ground wire (green or bare) from the supply to the green ground screw of 
the hood. Use approved methods for all connections 

(Figure 7).

2.  Install the wire compartment cover and tighten screw. Make sure all wiring is securely 

contained within the wire compartment.

SECTION 6

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

1.  Connect the ducting to the hood’s duct collar. Secure in place using tape to seal all joints 

(Figure 8).

Keyhole

1/8

"

Figure 6

Figure 8

Figure 7

Neutral 

(White)

From Hood

Hot (Black)

Ground 

(Green or Bare)

From Hood

Channel

Figure 9

ON

ASHRAE 62.2

OFF

Содержание ECQ Series

Страница 1: ...ilities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OU...

Страница 2: ...e sure the strips line up to the keyhole slots of the range hood SECTION 3 Prepare the Hood for Installation 1 To ensure the best air and sound performance it is recommended that the length of ducting...

Страница 3: ...with one controlling the lighting and the other controlling the exhaust fan The light switch has three positions Main Light Night Light and OFF The fan switch has three positions High Low and OFF SECT...

Страница 4: ...e base Installation is the reverse of removal Replace with Air King model 26SBL or a compatible 26W GU24 lamp Night Light Unscrew night light bulb from socket and replace with a 4 watt maximum type C7...

Страница 5: ...ST OCCURS AND IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOU...

Страница 6: ...lder Assembly 5S1199703 8 1 Capacitor Harness 5S1111019 9 1 Blower Assembly 5S1144001 10 1 Wire Compartment Cover 5S1144089 11 2 Grease Filter GF 01 5S1111033 12 1 Bottom Cover 30 White 5S1144333 30 B...

Страница 7: ...S DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES AVERTISSEMENT POUR USAGE DE VENTILATION G N RALE EXCLUSIVEMENT NE PAS UTILISER POUR VACUER DU MAT RIEL ET DES VAPEUR...

Страница 8: ...vous que les bandes sont align es aux encoches en trou de serrure de la hotte SECTION 3 Pr parez la hotte pour l installation 1 Pour garantir la meilleure qualit d air et performance acoustique il es...

Страница 9: ...ints Figure 8 MISE EN GARDE DIRIGEZ TOUJOURS LES CONDUITS DU VENTILATEUR VERS L EXT RIEUR EN VOUS ASSURANT QUE L EXTR MIT EST MUNIE D UN CAPUCHON DE MUR OU DE TOIT SECTION 7 R glage de la vitesse 1 Vo...

Страница 10: ...ens contraire des aiguilles d une montre pour lib rer la lampe de la base L installation est l inverse de la d pose L installation est l inverse du d montage Remplacez par le mod le 26SBL de Air King...

Страница 11: ...ING N ASSUME AUCUNE RESPONSABILIT EXPRESSE OU TACITE POUR I DES DOMMAGES ACCIDENTELS OU INDIRECTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEP...

Страница 12: ...006 7 1 Assemblement de support de lampe GU24 5S1199703 8 1 C ble du condensateur 5S1111019 9 1 Assemblement de ventilateur 5S1144001 10 1 Couvercle du compartiment des fils 5S1144089 11 2 Filtre grai...

Отзывы: