AirKing DH55 Скачать руководство пользователя страница 2

WIRING

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE 

IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL 

ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL 

WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

3a. 

Dehumidistat Only:

 For installations where the fan is to be controlled from the 

dehumidistat only. Connect the Black lead from the dehumidistat to the Hot (Black) wire 

from the power supply. Connect the Red lead from the dehumidistat to the Black wire from 

the fan. Connect the ground wire (green or bare copper) from the house to the Green 

screw of the mounting plate. Use approved methods for all connections 

(Figure 1).

3b. 

Dehumidistat with manual On switch:

 For installations where a switch (not included) to 

manually turn the fan on is preferred or required, run two Hot (Black) wires from the power 

source. Connect one Hot (Black) wire to the black lead of the dehumidistat. Connect the 

other Hot (Black) wire from the power source to the on switch. Connect the Red lead from 

the dehumidistat to the Black wire from the fan. Run a Black wire from the on switch to 

the Black wire of the fan (both the Black wire from the dehumidistat and the Black wire 

from the on switch will be connected to the Black wire from the fan). Connect the ground 

wire (green or bare copper) from the house to the Green screw of the mounting plate. 

Use approved methods for all connections 

(Figure 2).

www.airkinglimited.com

DH55 Rev. H 04-16

2 of 4

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original purchase or until the original 

purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same 

or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse, 

misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay return shipping 

charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF 

ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING’S 

LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACEMENT OR 

REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EX-

PRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or 

limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is 

required before a warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern. 

Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST 

HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

4.  Mount back plate securely to gang box with 

screws provided in the parts package.

NOTE:

 Make sure the back plate is flat without any 

undue stress.

5.  Re-install front cover by aligning the two holes 

on the top of the cover with the two posts on 

the plate. Secure with cover screw supplied in 

parts pack 

(Figure 3).

6.  Turn power on at circuit breaker or fuse panel.

OPERATING INSTRUCTIONS

Using the adjustment knob, turn the dehumidistat down to its lowest setting, then to the 

highest setting. Cycle at least 3 times to assure proper system function. Return control knob 

pointer to desired setting.

DEHUMIDISTAT:

 The dehumidistat is designed to automatically power the fan when the 

humidity level rises above the chosen level. If the fan is not operating, adjust the humidity 

setting on the dehumidistat to a lower setting. Once the desired humidity level is reached, the 

fan will automatically turn off. 

MANUAL ON SWITCH:

 An optional manual on switch allows the user to power the fan no 

matter what the humidity level is. When the switch is turned on, the fan will turn on. This is 

especially useful for odor control in bathrooms.

NOTE:

 Either the dehumidistat OR the on switch can power the fan. To turn the fan off, both 

the dehumidistat and the manual on switch must be off.

CAUTION:

 NEVER USE THE DEHUMIDISTAT SWITCH AS A 

MEANS TO TURN OFF THE POWER TO THE FAN WHEN SERVICING. ALWAYS 

TURN THE POWER OFF AT THE CIRCUIT BREAKER OR FUSE PANEL.

CALIFORNIA RESIDENTS ONLY:

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR 

CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL 

[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE 

REPRODUCTIVE TOXICITY.

Screw

Figure 3

Post

Fan

Neutral (White)

Hot (Black)

Dehumidistat

Figure 1

Hot (Red)

Ground

Hot (Black)

On/Off Switch

Dehumidistat

Figure 2

Fan

Neutral (White)

Hot (Red)

Ground

Отзывы: