1b. 

Internal Wire Compartment: 

Remove the screws holding the blower assembly in place 

and lift assembly out of housing 

(Figure 7)

. Remove the wire compartment cover screw 

and place the cover in a secure place 

(Figure 8).

NOTE:

 If the fan motor plug is 

connected to the fan housing 

receptacle, unplug so the 

blower assembly can be 

completely removed.

STANDARD MODELS

2b.  Run wiring from an approved wall switch carrying the appropriate rating. One neutral 

(White), one ground (green or bare copper), and three hot (Black, Purple, Yellow leads 

connected to the switch, one for each function). Secure the electrical wires to the 

housing with an approved electrical connector. Make sure you leave enough wiring in the 

box to make the connection to the fan’s receptacle.

2b.  From where you have chosen to access the fan’s junction box, connect the White wire from 

the house to the two White wires from the fan. Connect one Hot (Black) wire from the wall 

switch to the Black wire from the fan (this is the fan control). Connect second Hot (Purple) 

wire from the wall switch to the Purple wire from the fan (this is the night light control). 

Connect the third Hot (Yellow) wire from the wall switch to the Yellow wire from the fan (this 

is the main light control). Connect the ground wire (green or bare copper) from the house to 

the Green wire from the fan 

(Figure 9)

. Use approved methods for all connections.

HUMIDITY SENSING MODELS

3a.  For proper fan operation, the humidity sensing fan will require a 3 way switch (not 

included). Run wiring between the fan and the switch location. Make sure you leave 

enough wiring in each box to make the connections. At the switch box connect the Black 

wire from the house to the common terminal of the switch. Connect the black wire from 

the fan to one of the switched terminals on the switch. This position will energize the 

automatic mode and the fan will energize upon a rise in humidity. Connect the Red wire 

from the fan to the other switched terminal on the switch. This position will activate the 

Manual On feature and energize the fan. Use approved methods for all connections.

3b.  To operate the main light and the night light, run wiring from two toggle switches (not 

included). At the switch box, connect the Black wire from the house to the common 

www.airkinglimited.com

210572203 Rev. N 1-16

3 of 12

terminal of each toggle switch. Connect the Yellow wire from the fan to one of the toggle 

switches (this is the main light control). Connect the Purple wire from the fan to the other 

toggle switch (this is the night light control). Use approved methods for all connections.

3c.  From where you have chosen to access the fan’s junction box, connect the White wire 

from the house to the two White wires from the fan. Connect the ground wire (green or 

bare copper) from the house to the Green wire from the fan 

(Figure 10)

. Use approved 

methods for all connections.

NOTE:

 The fan’s receptacle wires might need to be pulled outside compartment for connection. 

Only pull the three loose wires outside of compartment. Additional wires will be present.
4.  Carefully tuck wires back inside wire compartment and replace wire compartment cover 

securing with the screw that was removed earlier.

SECTION 6

Completing the Installation

1.  Use a sealant appropriate for contact with the building materials present and for the 

temperature requirements of the installation to prevent air leakage from unconditioned 

spaces is recommended. If gaps between unit housing and ceiling are great, additional 

material (backing rod, ceiling material) may be required.

NOTE:

 This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan 

be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.  If the fan’s blower assembly was removed during the wiring process, reinstall the blower 

by reversing the directions in 

Step 1b

 in 

Section 5

 

Wiring

.

3.  Connect the fan wire harness by plugging the 3 pin quick connect end into the receptacle 

located on the side of the wire compartment cover. Confirm that the 5 pin quick connect 

end is plugged into the receptacle from the blower assembly. Connect the light wire harness 

by plugging the 3 pin rectangular quick connect end into the receptacle located at the top of 

the wire compartment. These cords will only fit one way into the receptacles 

(Figure 11)

.

4.  Install the included lamp into the lamp holder by lining up the pins on the lamp base to the 

socket of the lamp holder and turning the lamp body clockwise until the lamp snaps into 

place and is firmly seated in the lamp holder. Install a 4 watt maximum type C7 (candelabra 

base) night light (not included) into the side lamp holder 

(Figure 12).

 

Figure 6

Screw

Wire

Compartment

Cover

Figure 7

Screws

Plug

Venturi

Figure 9

Supply from house

Neutral (White)

Ground (Green or Bare)

Fa

n

Neutral (White)

Green

Hot (Black)

Yellow

Purple

Black

Figure 10

Supply from house

Neutral (White)

Ground (Green or Bare)

Fa

n

Neutral (White)

Green

Red

Hot (Black)

Yellow

Purple

Black

Hot (Black)

Hot (Black)

Figure 12

Lamp

Lamp Holder

Pin

Night Light

Socket

NOTE:

 Fluorescent lamp shown

Figure 8

Screw

Wire

Compartment

Cover

NOTE:

 Wire compartment configuration 

will be dependent on model.

Figure 11

NOTE:

 Wire compartment configuration will be dependent on model.

Содержание AKF50

Страница 1: ...d for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When c...

Страница 2: ...e rails to the joists Figure 2 www airkinglimited com 210572203 Rev N 1 16 2 of 12 SECTION 4 Ducting NOTE 4 OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct ...

Страница 3: ...ntrol Use approved methods for all connections 3c From where you have chosen to access the fan s junction box connect the White wire from the house to the two White wires from the fan Connect the ground wire green or bare copper from the house to the Green wire from the fan Figure 10 Use approved methods for all connections NOTE The fan s receptacle wires might need to be pulled outside compartmen...

Страница 4: ...store power SECTION 8 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION 1 Cleaning the Grill Remove grill and dislodge reflector from grill by sliding the reflector notches from beneath the lens clips on grill Use a mild detergent such as dishwashing liquid to clean then dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completel...

Страница 5: ... not cover shipping costs for the return of products to Air King for repair or replacement Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SE...

Страница 6: ...ire Cover Assembly AKF100 5S1202622 1 Wire Cover Assembly AKF80H 5S1202623 1 Wire Cover Assembly AKF100H 5S1202624 5 1 Blower Assembly AKF50 5S2202029 1 Blower Assembly AKF80LS 5S2202029 1 Blower Assembly AKF100 5S2202401 1 Blower Assembly AKF80H 5S2202401 1 Blower Assembly AKF100H 5S2202401 6 1 Light Assembly 5S1202798 7 1 Outlet Gasket 5S1202043 8 1 Grill Assembly 5S1202620 9 1 26W CFL Lamp 5S99...

Отзывы: