AirKing 4C945J Скачать руководство пользователя страница 1

8. This Fan is intended for general use ONLY. It must NOT be used in

potentially dangerous locations such as flammable, explosive,
chemical-laden or wet atmospheres. DO NOT use Fan in a window.
Rain may create an electrical hazard.

WARNING:  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL
DEVICE.

ASSEMBLY

1. Push the end of the Large Diameter Pipe, without holes, into the

Base. You may have to turn the Pipe while pushing to completely seat
into Base

(Figure 1)

2. LEAVE SPRING IN BAG and drop into Large Diameter Pipe

(Figure 2)

3. Firmly push Plastic Bushing into end of Extension Pipe that has

raised "bumps". 

(Figure 3)

4. Slide Retainer over Extension Pipe. Set the Extension Pipe into

Column

(Figure 4)

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY WITH INSTRUCTIONS

COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

1

2084070A

Rev. C 5/00

OPERATING INSTRUCTIONS & PARTS MANUAL

UNPACKING

When unpacking the unit, inspect carefully for any damage that may have
occurred during transit. Check for loose, missing, or damaged parts.

GENERAL SAFETY INFORMATION

1. Make certain that the power source conforms to the electrical

requirements of the Fan.

2. The power cord is equipped with a three-prong grounded plug that must

be inserted into a matching receptacle.  Under no circumstances must the
grounding prong be cut off the plug.  Where a two-prong wall receptacle
is encountered, it must be replaced with a properly grounded three-prong
receptacle installed in accordance with the National Electrical Code
(NEC) and all applicable local codes and ordinances.  This work must be
done only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER
IS NOT RECOMMENDED.  IMPROPER CONNECTION MAY
CREATE THE RISK OF ELECTROCUTION.  USE OF SUCH
ADAPTERS IS NOT PERMITTED IN CANADA.

3. Where possible, avoid the use of extension cords.  If they must be

used, minimize the risk of overheating by ensuring that they are UL
listed and of the proper gage and length.  Never use a single extension
cord to operate more than one Fan.

4. Do not insert fingers or foreign objects into the Fan. Do not block or

tamper with the Fan in any manner while it is in operation.

5. To avoid the possibility of overturning the fan, ensure that it is on a

stable, level surface.

6.  Unplug power cord before installing or servicing the Fan.

7. Completely reassemble Fan, according to instructions, before

reconnection to power supply.

WARNING:  DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR
SERVICING THE FAN.  ALWAYS UNPLUG THE POWER CORD.

DESCRIPTION

The AirKing 16" Pedestal Stand Fan features 3-speed rotary knob
operation and two height adjustments. The 16" (40.6 cm) 3-paddle blade
is driven by a permanent split capacitor motor with a 6' (1.8 m) 18/3
cordset.

SPECIFICATIONS

Motor ....................................... 120V, 50/60 Hz

Blade diameter ....................... 16" ( 40.65 cm)

Speeds .................................... 3

Control .................................... Rotary Switch

Air flow distribution ................. 90

°

 Variable

Approvals ................................ UL Listed. Close mesh fan guard meets

OSHA requirements.

16" PEDESTAL STAND FAN

MODEL 4C945J/9126J

Figure 2

Figure 3

Figure 5

Figure 6

Figure 7

Figure 4

Figure 1

5. Insert Extension Pipe Retainer into Large Diameter Pipe. Fasten

with two #6-5/16" Phillips pan head Screws. DO NOT OVERTIGHTEN.
(Figure 5)

6. Slide height adjustment nut over Extension pipe

(Figure 6)

CAUTION: DO NOT TIGHTEN THE HEIGHT ADJUSTMENT
NUT UNTIL MOTOR ASSEMBLY IS INSTALLED.

7. Lower Motor Assembly onto Extension Pipe, turn until Pipe seats

and holes at rear line up. Fasten with Screw as shown. 

(Figure 7)

8. Tighten Height Adjustment Nut. Do not over tighten.

Base

Large
Diameter
Pipe

Spring

Plastic
Bushing

Extention
Pipe

Retainer

Extention Pipe
Retainer

Phillips
Screws

Height
Adjustment
Nut

Motor
Assembly

MODEL

4C945J/9126J

SPEED    HIGH

  MED

LOW

CFM         2681          2355          2000

M

3

/s

    1.27

   1.11

0.94

RPM

    1400

  1230

1045

Amps

    .61

   .51

.45

Watts

    70

  60

 55

 dB A

   53

 49

 44

MODELO 4C945J/9126J

2084070A

Rev. C 5/00

4

Ref.

 Parte No.

Descripción

                 Cant.

40

8

7

6

5

9

10

11

4

3

2

29

26

22

21

1

12

13

14

15

17

18

19

23

20

24

25

27

28

31

32

16

30

33

34

35

36

37

39

38

Innovators in Home Comfort

TM

Pasador

Ranura
Del Cubo

Innovators in Home Comfort

TM

R

Figura 5

Figura 6

Figura 7

5. Con la Cabeza del Ventilador inclinada hacia atrás y centrada, alinear

el Adorno de tal manera que la divisa quede horizontal. Insertar la
parte inferior de la Rejilla Métalica Delantera dentro de la Rejilla
Plástica
  Trasera. La proyección de la parte inferior de la Rejilla
Plastica Trasera
 debe quedar entre dos Alambres de la parte
delantera. Cerrar apretando la parte delantera contra la parte trasera
empezando en la parte superior y continuar cerrando hacia abajo
ambos lados. 

(Figure 8)

ADORNO

Figura 8

R

MOTOR

TUERCA DE
PLASTICO

HELICE

TAPA

APÉNDICE

PUNTOS
DE
CIERRE

PUNTOS
DE
CIERRE

REJILLA PLÁSTICA
TRASERA

REJILLA
PLÁSTICA
TRASERA

REJILLA

DELANTERA

OPERACIÓN

OSCILACIÓN

1. Tire hacia afuera del botón de oscilación que se encuentra en la parte

trasera del motor para poner el Ventilador en posición fija.

2. Oprima el botón de oscilación y el Ventilador oscilará de lado a lado.

INCLINACIÓN

El ángulo de inclinación se ajusta empujando la Cabeza del Ventilador
hacia adelante o hacia atrás.

AJUSTE DE LA ALTURA

Para ajustar la altura del Ventilador, afloje la Tuerca de Ajuste de Altura,
cuidadosamente eleve o baje el Ventilador, y vuelva a apretar la tuerca firmemente.

VELOCIDAD

La velocidad se controla girando el conjuntor rotatorio que se encuentra en
la parte trasera del alojamiento del motor.

MANTENIMIENTO

ADVERTENCIA: DESCONECTE SIEMPRE EL CORDÓN ANTES DE
MOVER O DAR SERVICIO AL VENTILADOR.

LIMPIEZA

Utilice un trapo suave, humedecido con una solución de jabón suave. Evite el
uso de gasolina, bencina, diluyentes, solventes clorados, limpiadores ásperos,
etc., ya que causarán daños al Ventilador.

LUBRICACIÓN

Los cojinetes de precisión vienen sellados de fábrica de por vida y no requieren
de lubricación adicional.

ALMACENAMIENTO

Cuando no esté en uso, guarde la unidad en un lugar limpio y seco.

ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O
DESCARGAS ELÉCTRICAS, NO USE ESTE VENTILADOR CON NINGÚN
DISPOSITIVO DE CONTROL DE VELOCIDAD DE ESTADO SÓLIDO.

ENSAMBLE DE LA HELICE Y LA REJILLA

1. Inclinar la Cabeza del Ventilador hacia atrás. Coloque la Rejilla

Plástica Trasera en el Motor

(Figura 5) Alinear el corte triagular "

"

de la Rejilla Plástica Trasera con la protuberancia triangular de la
parte superior de la cubierta del Motor. (

Figura 6)

2. Asiente la Rejilla y sujetela con la Tuerca de PlásticoHacia la Derecha.

3. Deslice la Helice en el Eje del Motor. (Alinear la Ranura Del Cubo de

la Tapa con el Pasador del eje del motor.) 

(Figura 7)

4. Para asegurar la Paleta, enroscarla hasta que quede apretada

en el Cubo de la Tapa haciéndola girar Hacia la Izuierda.

1

2010815

Tuerca de Ajuste de Altura

1

2

2010814

Retén de Columna (Collar)

1

3

2098040

Tornillo de Cabeza Phillips #6 x 5/16"

2

4

2069006G

Tubo de Diámetro Grande

1

5

2011862B

Base (Redonda)

1

6

2060027P

Peso (Acero)

1

7

2090038

Tornillo de Cabeza Phillips #8 x 9/16"

6

8

2090092

Tornillo de Fijación de Cabeza
       Phillips #8 x 12

1

9

2098127D

Resorte (En Bolsa)

1

10

2010809

Casquillo a Presión

1

11

2061049

Tubo de Extensión

1

12

2090019

Tornillo Phillips de Cabeza
       Reforzada #7 x 5/8"

1

13

2010803

Botón del Interruptor

1

14

2010677

Cubierta del Motor (Trasera)

1

15

2010810

Soporte del Interruptor

1

16

2055087

Interruptor

1

17

2010121

Botón de Oscilación

1

18

2030066GS

Motor

1

19

2010710

Cubierta del Motor (Frontal)

1

20

2090080

Tornillo # 7 x 5/16"

2

21

2090140

Tornillo de Enlace

2

22

2010276

Enlace

1

23

2010808D

Casquillo del Cuello

1

24

2010162B

Placa de Trinquete

1

25

2010258D

Pieza del Cuello

1

26

2090586

Resorte de Elevación

1

27

2090516

Perno de Tope

1

28

2090033

Tuerca Hexagonal

1

29

2090027P

Tornillo Phillips de Cabeza Reforzada
       #8 x 1/2 Para el Collar

1

30

2090521

Eje de Elevación

1

31

2010821

Collar

1

32

2050042W

Cordón Eléctrico

1

33

2011200

Rejilla Trasera

1

34

2010359

Tuerca de Plástico

1

35

2011013

Paletas

1

36

2010059

Rotor

1

37

2096214P

Rejilla Frontal

1

38

2010238

Ornamento de la Rejilla

1

39

2070024G

Ojo de Buey AirKing

1

40

2090529

Tuerca Para Alambre A-O

1

Отзывы: