background image

Rev. A 9/05

1

2084779

DIGITAL RECIRCULATING HUMIDIFIER

9 GALLON  MODEL 3LA79A/9929A

READ AND SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS & PARTS MANUAL

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

DESCRIPTION

The AirKing 9 Gallon (34.1 liter) Humidifier features 3-Speed whisper
quiet operation.  This unit is capable of humidifying up to 3200 sq. ft.
(355.6 sq. yards) and features a 7.5 ft. (2.3 m) 18/3 cord set.

SPECIFICATIONS

Motor .................................... 120V, 50/60 Hz
Blade diameter .................... 9" (22.86 cm)
Speeds ................................. 3
Control ................................. Rotary Switch
Approvals ............................. UL/CUL Listed

MODEL

3LA79A/9929A

SPEED

HIGH

MED

LOW

RPM

1300

1100

900

Amps

0.590

0.500

0.450

Watts

62.8

58.8

49.8

dB A

 61

59

53

NOTE: A few droplets of water may be present
in your Humidifier as a result of our quality
testing prior to packaging and shipment.

DO NOT pour water into Grill. DO NOT spill water on Control Panel.

Water should only be poured into the Unit using the Jug.

CAUTION: DO NOT fill unit
before assembling.

1. Remove Water Jug then,

Upper Housing from base
of unit.

 (Figure 1)

2. Lay base of unit on it’s side

so the bottom of the unit
is facing you.

3. Fully insert the four Castors into

the holes in the bottom of the unit.
(Figure 2)

4. Replace Upper Housing, then Wa-

ter Jug into unit.

ASSEMBLY

Figure 1

Base

Upper Housing

Water Jug

MODEL 3LA79A/9929A

TROUBLE

PROBABLE CAUSE

SOLUTION

Fan not working or

No power

Make sure Unit is plugged in

Humidifier doesn’t

Check that the Power Switch is On

turn on

Humidistat not set correctly

Set Humidistat to higher humidity level

Top of Humidifier not seated properly

Make sure top is properly seated on Base

on Base (Unit is equipped with an
automatic shut off)

Filter Holder not assembled properly

Make sure Filter Holder is seated in place

or is missing (Unit is equipped with an
automatic shut off)

Water leaking

Base is overfilled

Reduce water level in Base

Filter is old and dirty

Replace Filter

Foul odor

Filter needs to be replaced

Replace Filter

Base needs to be cleaned

Follow Instructions in CLEANING section

Whole Humidifier needs cleaning

Follow Instructions in CLEANING section

Filter discoloration

Mineral deposits in water

Replace Filter

Water discoloration

Humidifier needs to be cleaned

Follow Instructions in CLEANING section

Hard water - Iron in water

Use filtered or distilled water

Some humidifier additives can cause
discoloration

Lights do not work:

Humidistat Light Off,

Humidity is not yet achieved in room

Allow Humidifier to continue running

Power Light On
Power Light Off,

Room has reached desired

Set Humidity Knob for more Humidity

Humidistat Light On

Humidity level

No water show

No water in Unit

Refill Unit

Hose not connected to Pump

Connect Hose to Pump

Hose not connected to Water Show

Connect Hose to Water Show

TROUBLE SHOOTING GUIDE

Figure 2

Hole

Castor

Rev. A 9/05

4

2084779

 1

2010598

Humidifier Top

1

 2

02091220I

Screw #8 x 1/2 PPH Type 30A ZP

15

 3

02030008EG Motor/Control Box Assembly

1

 4

2010588

Chassis

1

 5

2010590

Drip Shield

1

 6

2010591EG

Base

1

 7

2010592

Front Filter Holder

1

 8

2010593

Rear Filter Holder

1

 9

02010860S

Lever

1

10

02010861

Spring

1

11

02010862

O-Ring

1

12

02010871

Plunger

1

13

2010844

Jug

1

14

2010597

Jug Top

1

15

2010596

Jug Lid

1

16

02010868S

Water Distribution Block

1

17

02010869S

Water Show Assembly

1

18

2010870

Filter

1

19

2011073

Blade

1

20

2011074

Basket

1

21

2069093

Tube 1/4” x 24 1/2”

1

22

2069094

Tube 1/4” x 15 1/2”

1

23

02091221I

Screw #8 X 3/4” PTH Type 30A ZP

7

24

02098038

Castors

4

25

02010601

Handle

1

26

02010867S

Impellor

1

27

02010866LS Lower Pump Housing

1

28

02010866US Upper Pump Housing

1

KEY PART NO.

DESCRIPTION

QTY.

1

2

3

4

16

21

2

5

6

19

20

23

3

22

17

28

26

27

25

14

13

12

11

15

10

9

7

8

18

24

GENERAL SAFETY INFORMATION

1. Make certain that the power source conforms to the electrical require-

ments of the Humidifier.

2. The power cord is equipped with a three-prong grounded plug that

must be inserted into a matching receptacle.  Under no circum-
stances must the grounding prong be cut off the plug.  Where a two-
prong wall receptacle is encountered, it must be replaced with a
properly grounded three-prong receptacle installed in accordance
with the National Electrical Code (NEC) and all applicable local
codes and ordinances.  This work must be done only by a qualified
electrician, using copper wire only.

WARNING:  USE OF A THREE-PRONG TO TWO-PRONG ADAPTER
IS NOT RECOMMENDED.  IMPROPER CONNECTION MAY CREATE
THE RISK OF ELECTROCUTION.  USE OF SUCH ADAPTERS ARE
NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT
REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY
SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS
PLUG. RETURN TO AN AUTHORIZED SERVICE CENTER OR CALL
800-233-0268, MONDAY - FRIDAY, BETWEEN 8:00 AM AND 5:00 PM
EST. IF THE PLUG WARNING LABEL IS MISSING OR DAMAGED,
CALL THE TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
3. 
Where possible, avoid the use of extension cords.  If they must be

used, minimize the risk of overheating by ensuring that they are UL
listed and of the proper gage and length.  Never use a single extension
cord to operate more than one Humidifier.

4.  Do not insert fingers or foreign objects into the Humidifier.  Do not block

or tamper with the Humidifier in any manner while it is in operation.  Do
not touch the Humidifier while in operation or just after it has been
turned off, as some parts may be hot enough to cause injury.

5.  Unplug power cord before filling or servicing the Humidifier.

WARNING:  DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE
MEANS OF DISCONNECTING POWER WHEN FILLING OR SERVICING
THE HUMIDIFIER.  ALWAYS UNPLUG THE POWER CORD.
6. 
This Humidifier is intended for general use ONLY.  It must NOT be

used in potentially dangerous locations such as flammable, explo-
sive, chemical-laden or wet atmospheres.

WARNING:  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS HUMIDIFIER WITH ANY SOLID STATE SPEED
CONTROL DEVICE.
7. 
Always place the Humidifier is on a stable, flat, level surface when

operating, to avoid the chance of the Humidifier overturning.  Locate
the Power Cord so the Humidifier or other objects are not resting on it.
Keep the Power Cord away from room traffic.

8. Always direct air flow away from walls and furniture. Excessive moisture

may cause damage.

9. Completely reassemble Humidifier, according to instructions, before

reconnecting to power supply.

10. Humidifiers require regular cleaning to maintain proper operating condi-

tions.  Refer to the CLEANING section for proper cleaning procedures.

Отзывы: