background image

Mount the worm box (3) (fig. C). The worm box 

has been fitted with a bayonet catch. The fan and 
the motor plate have already been mounted on the
worm box.

If required, the motor plate and the cover (4) can be

removed again (fig. D). 

Now mount the discharge line between the wing nozz-

le of the ventilator and the roof lead-through.

The electric connection has been indicated in figu-
re E.

Connect the switch to a Perilex wall socket.

Insert the Perilex plug of the home ventilator in the

Perilex wall socket.

Legend to figure E:
N = zero

U1

= main w auxiliary winding

(blue)

L1 = high speed

Z

= auxiliary winding (brown)

L2 = middle speed

U2

= main winding (black)

L3 = low speed

CV-3 = 3 positions switch

USE
- Put for minimum use the switch in position 0 

(night position).

- Put for normal ventilation in the daytime situation, 

the switch in position 1 (day position).

- Put for maximum ventilation the switch in position 2

(cooking position).

MAINTENANCE
This appliance has been designed to function without
problems for a long time without the need for special
maintenance.

CLEANING

Always remove the plug from the Perilex wall 
socket before starting any maintenance activities.

Regularly clean the housing with a soft, damp cloth.

SERVICE
This electric appliance has been thoroughly tested befo-
re leaving the factory. Should your home ventilator
despite this show any defects, have it sent back to the
Airflow service department by your installer.

DECLARATION OF CONFORMITY

Airflow declares that this home ventilator WHV-8 has
been designed in compliance with 89/392/EEC.

This electric appliance has been radio and TV 
suppressed in compliance with directives 76/889/EEC &
82/499/EEC.

4

2x

FIG. D

45

0

3

terminal strip WHV - 8 

earth directly 

connected to motor

Perilex plug
Perilex wall socket

supply voltage 

230V

CV - 3

N L3 L2 L1 U1 Z U2

FIG. C

FIG. E

Telephone: +44 (0) 1494 525252 

Fac44 (0) 1494 461073

©

 

Developments Limited reserve the right, in the 

interests of continuous development, to alter 

are accepted subject to our conditions of sale 

which are available on request

Certificate No. EMS 569454

BS EN ISO 14001 : 2004

Certificate No. FM 00152

BS EN ISO 9001 : 2008

Aidelle House, Lancaster Road,

Cressex Business Park,

High Wycombe, Buckinghamshire,

HP12 3QP

Отзывы: