5.0 Repair and maintenance

m

 DANGER

Touching of live electrical parts can cause an electrical shock. 

Isolate device from the mains power supply and secure against being 

switched on again!

Maintenance is not provided for the power supply unit and the unit must be 

fully replaced in case of defects!

6.0 Disposal

Packaging must be correctly disposed of. The electrical devices 

must be returned to collection points for the recovery of electrical 

and  electronic  waste.

 

According  to  §  12  of  the  Battery 

Directive  (BattV),  accumulators  and  batteries  must  be 

returned to the manufacturer or an 

appropriate  collection 

point.  Electrical  devices,  accumulators  and  batteries  may 

not  be  disposed  of  with  household  waste.

4.0 Technical data

230 V~

Nominal i

nput voltage

100

 V AC

-

240 V AC

, 45-65 Hz/ 0 Hz

  

Input o

perating voltage range

85

-2

64

V AC

 / 95-250 V DC

 (with fuse)

Output voltage

12.0 V DC / 1.

5

A       

18

 W

Inrush current limitation (at 25°C)/l

2

t

Input fuse

1.25 A 

Permissible backup fuse:circuit breaker B6/B10/B16

 

Nominal output voltage U

N

, current I

N

12 V DC +/-1%, 1.5 A

Max. power dissipation

<0.4 W / <3.2 W

Efficiency (for 230 V AC and nom.val.)

>

84%

Insulation voltage (Input/Output)

2 kV AC

Ingress protection

IP20

Class of protection

II

Pollution degree

2

Ambient

 temp

er

ature

 (operation)

-

25

 °C to 

70

 °C

Safety:

Input side

Protection class II

Output side

Protection class III Safety extra-low 

voltage SELV compliant

Safety approval

acc. to EN60950-1 and EN60335-1

<15 A / <0.1 A

2

s

Humidity at 25°C, no condensation

<95%