background image

SUITABLE LOCATIONS

The Threesome has been designed especially for cavity type ceilings. Flat roof installation is 
NOT recommended.

Threesome must not be mounted in areas subject to direct splashing. Threesome must 
be mounted in the horizontal position only. Unsuitable for ‘cathedral’ or ‘raked’ ceilings. 
Threesome comes with 4 Infra-red Heat Globes which emit harmless radiant heat. 
Threesome is best positioned directly above the area requiring warmth. Before you start, 
make sure your ceiling has at least 280mm clearance from the roof (see diagram 2). 

WHERE TO LOCATE

Radiant globe heaters are not designed to heat entire rooms. They provide instant, 
concentrated heat to persons standing directly below the heat lamps. Therefore, units should 
be located over the area where drying off takes place, not directly over a shower  

 

or bath. 

These heaters are not designed to be left on for extended periods of time, as this could 
cause overheating and premature failure. Threesome units, even those without fans, should 
not be covered or installed in situations which restrict the natural ventilation of the units for 
cooling purposes. 

Ceiling insulation should be kept well clear of the units (at least 100mm). For optimum 
performance, models with exhaust fans should be installed in areas with good ventilation, 
to enable fresh air to flow into the room. It is recommended that there is at least a 500mm 
clearance above the unit, and that the ceiling space is adequately ventilated to allow 
appropriate air flow through the unit. Any restrictions on return air entering the room, or 
exhausted air escaping from the ceiling space, will impair effectiveness and may contribute to 
premature failure.

RADIANT HEAT

Threesome requires no warm up period because of its efficient, Radiant Heat Globes. Heat 
is directed at you for an instant warmth you can feel, rather than gradually warming the entire 
room. Because of this, Threesome only needs to be turned ON when you are in the room.

MOUNTING

1. 

Using this card in its open state as a template, position it 
in the area you want your Threesome and draw around 
the edges with a pencil to mark the hole cutting size. 
BE SURE TO CHECK ABOVE THE CEILING FOR 
MINIMUM SPACE OF 280mm (for optimum performance 
allow 500mm or more clearance) AND THE LOCATION 
OF THE CEILING JOISTS. Ensure there is a minimum 
of 100mm clear space between the Threesome unit and 
any ceiling insulation.

2.

 Use a saw to cut the section along the drawn lines.

3.

 The lamp surround easily unclips from the main body 

by lifting gently from any side. Remove it and the 4 heat 
globes to avoid damage from knocks and vibrations. 
Now insert your Threesome with both side springs pulled 
inwards so that the body can pass through the hole 
without damaging the plaster. Return springs to original 
position to fix body securely to the ceiling.

NOTE:

 Springs are adjusted to suit either 10mm or 13mm 

plasterboard ceiling. 

4.

Clip the lamp surround back onto the body making sure 
both clips snap into place. Fit retaining spring as shown 
in diagram.

5.

The lamp surround has been shaped to position heat 
globes correctly in the main body. Screw the four, large 
heat globes through the lamp surround holes, tightening 
firmly to ensure a good electrical contact. DO NOT 
FORCE OR OVER-TIGHTEN. Screw centre light globe 
into place. Centre lampholder is designed to accept 100 
Watt (max), reflector type, R80, screw in light globes.

IMPORTANT SAFEGUARDS

•   The Threesome is not intended for use by young children or infirm persons without supervision.
•   Young children should be supervised to ensure that they do not play with the appliance.
•   Ensure that the switch is in the off position when changing the heat lamp (globe) or light globe.
•   Ensure that the wattage of a replacement globe is the same as the globes supplied with the unit.
•   Ensure the grille is free of objects, dust build up, etc. Make sure that the air flow through the 

grille is not inhibited.

ELECTRICIANS’ WIRING INSTRUCTIONS

Your Threesome requires a 230/240 Volt, 50Hz electrical supply. All electrical work must 
be carried out by a qualified electrician and installed in accordance with relevant Electrical 
Wiring Regulations.
Your new Threesome comes with all required switches and mounting plate.

WIRING DETAILS

1.

Decide the best position for the switch set and mount it. Be sure to click the switches into 
the backing plate in the desired order beforehand.

2.

Connect wiring to switches as shown in the appropriate electrical diagram.

3.

Remove screws from 
terminal cover on the 
Threesome and put aside. 
Wire according to the 
label beside the terminal 
strip. Once the wires 
are connected incoming 
cable must not be fouled 
by cover. Use appropriate 
knockouts in terminal 
cover to accommodate 
cable before replacing. 
Screw down firmly.

TEST

Clean surround and globes with a soft, moist cloth. Check power is switched on and all
switches activate properly, according to their marked function.

CLEANING

•   Ensure the Threesome is switched off before cleaning.
•   Remove globes when they are at room temperature. Wipe with a damp cloth, never immerse.
•   Unclip lamp surround and wash in warm, soapy water. Always use a soft cloth, never abrasives.

  Clean away any excess fluff from the inside of the body, motor blade brackets.

PERMANENT

APPLIANCE

WIRING

E

NEUTRAL

HEAT

FAN

HEAT

LIGHT

SWITCHES     EARTH

ACTIVE