background image

Surface mounting fans on the ceiling 

 

 

 

 

 

 

 

 

When surface mounting the iCON 30 and iCON 60, the mount-

ing  skirt  provided  should  be  used.  The  mounting  skirt  should 

be fixed, with the screws provided, into the support. The fan is 

then fitted into the skirt. 

The 

iCON  30

  requires  a  110mm  diameter  hole  through  the 

ceiling. 

The 

iCON  60

  requires  a  160mm  diameter  hole  through  the 

ceiling. 

Where flexible duct is used the diameter must be maintained. 

Condensation 

 

 

 

 

 

 

To  avoid  the  backflow  of  condensation  into  the  fan 

in  ceiling 

installations

  it is  good practice  to fit a  condensation  trap 

to the vertical outlet duct of the fan. With

  thru-the-wall  instal-

lation

 fit the duct in an approx. 5° angle down to outside.  

Measurements and commissioning 

The  Building  Regulations  2010,  Statutory  Instrument  Part  9, 

§42, imposes a  requirement that testing and reporting  of me-

chanical ventilation performance (see Approved Document F1) 

is conducted in accordance with an approved procedure.  

Compliance  with  this  requirement  by  an  assessed  and  regis-

tered  ‘Competent  Person’  should  follow  a  ‘Best  Practise’  pro-

cess and adopt air flow measurement, Method A - The Uncon-

ditional  Method  -  using  a  suitable  UKAS  certified  measuring 

instrument. Generically referred to as ‘Zero Pressure Air Flow 

Meter’ or ‘Powered Flow Meter’.  

Further information on this method is detailed in NHBC Build-

ing  Regulations  Guidance  Note  G272a  10/13  and  BSRIA 

Guide document BG 64/2016. 

Installation with flexible ducting 

Where  flexible  ducting  is  used  the  diameter  must  be  main-

tained  and  it  is  good  ventilation  practice  that  the  ducting  is 

extended to a minimum of 90% its possible length in order to 

maintain the best possible air flow.  

Ensure that flexible duct connections are not over tightened to 

the spigots.  

To  maximise  the  air  flow  rigid  ducting  should  be  used  where 

possible.  The  fan  and  ducting  should  be  installed  in  accord-

ance  with  the  requirements  of  the  Domestic  Ventilation  Com-

pliance Guide, part of the Building Regulations.  

SAFETY  FIRST: ALWAYS ISOLATE  THE FAN UNIT FROM 

THE  POWER  SUPPLY  BEFORE  DOING  ANY  WORK  ON 

THE FAN/MODULE. 

When installed according to these instructions the iCON range 

is  completely  safe.  The  materials  used  do  not  constitute  a 

hazard.  

Cleaning 

 

Fan  and  ducting  should  be  inspected  and  cleaned  on  a 

regular basis to keep fan performance. 

The external hous-

ing  of  the  fan  can  be  wiped  with  a  damp  cloth.  Do  not  use 

household  cleaners  containing  abrasives.    Cleaning  of  the 

internal  parts  such  as  the  impeller  should  be  carried  out  by 

using a soft brush. Never clean any parts of the fan assembly 

by immersing in water or using a dishwasher.  

Warning  

This appliance can be used by children aged from 8 years and 

above  and  persons  with  reduced  physical,  sensory  or  mental 

capabilities or lack of  experience  and  knowledge if they  have 

been  given  supervision  or  instruction  concerning  use  of  the 

appliance in a safe way and understand the hazards involved. 

Children should not play with the appliance. Cleaning and user 

maintenance shall not be carried out by children without adult 

supervision. 

Applicable to units installed and used in the United Kingdom.  

Airflow  Developments  Ltd  guarantees  the  iCON  for  3 

years  from  date  of  purchase  against  faulty  material  or 

workmanship.

  You  can  register  your  warranty  on-line  (for 

more  information  check  at  www.airflow.com).  Warranty  only 

covers the fan, not the reinstallation if required. In the event of 

any  defective  parts  being  found,  Airflow  Developments  Ltd 

reserve the  right  to  repair or  at  our  discretion replace  without 

charge provided that the unit:  

1. Has  been  installed  and  used  in  accordance  with  the  fitting 

and wiring instructions supplied with each unit. 

2. Has not been connected to an unsuitable electrical supply.  

3. Has not been subjected to misuse, neglect or damage.  

4. Has  not  been  modified  or  repaired  by  any  person  not  au-

thorised by Airflow Developments Ltd  

5. Has been installed in accordance with latest Building Regu-

lations  and  IET  wiring  regulations  by  a  recognised  compe-

tent installer. 

Airflow Developments Ltd shall not be liable for any loss, injury 

or other consequential damage, in the event of a failure of the 

equipment or arising from, or in connection with the equipment 

excepting only that nothing in this condition shall be construed 

as to exclude or restrict liability for negligence. 

This warranty does not in any way affect any statutory or other 

consumer rights.  

For  detailed  standard  warranty  terms  and  conditions  see 

our website or contact Customer Service. 

UK Head-Office 

AIRFLOW DEVELOPMENTS Ltd 
Aidelle House, Lancaster Road 

Cressex Business Park 

High Wycombe 
Buckinghamshire  

HP12 3QP 

United Kingdom 

 
Tel:        +44 (0) 1494 525252 

Email:    [email protected] 

Web:      www.airflow.com 

Czech Republic 

AIRFLOW LUFTTECHNIK GmbH 
o.s. Praha 

Hostýnská 520 

108 00 Praha 10 
Malešice 

Czech Republic 

 

 
Tel:        +42 (0) 2 7477 2230 

Email:    [email protected] 

Web:      www.airflow.cz 

Germany 

AIRFLOW LUFTTECHNIK GmbH 
Postfach 1208 

D-53349 Rheinbach 

Germany 
 

 

 

 
Tel:         +49 (0) 222 69205 0 

Email:     [email protected] 

Web:       www.airflow.de 

Optional control modules available for iCON 230V 

* Not recommended for kitchen applications with iCON 15. 

 

 

 

Choose from optional colour covers

 

© Airflow Developments Ltd.

  

Airflow Developments Limited reserve the right, in the interests of continuous develop-

ment, to alter specifications without prior notice. All orders are accepted subject to our 

conditions of sale which are available on request.  

Fitting in the ceiling 

Page 9 of 16 

When  recessing  or  surface  mounting  fans  in  the  ceiling,  a 

plywood  support  (min.  18mm  thick)  should  be  mounted  be-

tween  the  ceiling  joists.  Any  fixing  screws  should  be  fitted 

through the plaster board into the support. 

Important 

Fans should not be fitted to unsupported plaster board.  

Recessing fans in the ceiling 

 

 

 

 

The  fan  should  be  fitted  in  the  hole,  fixed  with  the  screws 

provided into the support. 

The 

iCON  15 

requires  a  110mm  diameter  hole  through  the 

ceiling.  

The 

iCON  30 

requires  a  160mm  diameter  hole  through  the 

ceiling.  

The 

iCON  60

  requires  a  190mm  diameter  hole  through  the 

ceiling.  

Where flexible duct is used the diameter must be maintained. 

Possible cable 

routing 

Duct 

Joist 

Ceiling 

Plywood 

Fitting in the ceiling 

Page 10 of 16 

Possible cable 

routing 

Duct 

Joist 

Ceiling 

Plywood 

Mounting skirt 

Best practise recommendations 

Plastic pipe 

Condensation 

trap 

Outlet drain to 

the outside 

Fan 

Page 11 of 16 

Best practise recommendations 

Page 12 of 16 

Page 13 of 16 

Maintenance 

Page 14 of 16 

Warranty 

Page 15 of 16 

Options 

Part no. 

Model 

Description 

72573602 

PCM 

Pull cord (manual on/off) 

72612601 

TM 

Timer (overrun 1-30 min) 

72675702 

DTM 

Delayed timer (2 min delay, overrun 2-45 min, pull cord) 

72687103 

HTM 

Humidity timer (40-90% RH, overrun 2-45 min, pull cord) 

72687104 

PRTM 

PIR timer (motion sensor, overrun 2-45 min) 

72687102 

PRHTM 

PIR with humidity timer (motion sensor, 40-90% RH, overrun 2-45 min) 

72675703 

2SHM* 

2 speed humidity (low speed 8 or 13 l/s, boost at 40-90% RH, pull cord) 

Covers for iCON 15 

Part no. 

Colour 

52634503B 

Anthracite

 

52634505B 

Sandstone

 

52634504B 

Silver

 

52634502B 

Chrome

 

Covers for iCON 60 

Part no. 

Colour 

52634509B 

Anthracite

 

52634511B 

Sandstone

 

52634510B 

Silver

 

Covers for iCON 30  

Part no. 

Colour 

52634506B 

Anthracite

 

52634508B 

Sandstone

 

52634507B 

Silver

 

 

www.airflow.com 

Отзывы: