230V Fan Range 

Installation and Operating Guide 

iCON 15  –  72683501 

iCON 30  –  72591601 

iCON 60  –  72591701 

Fan dimensions 

Page 2 of 16 

Airflow® iCON® 230V fans are available in three model sizes 

and can be fitted to a wall or ceiling.  

iCON 15 -100mm axial fan 

iCON 30 -100mm mixed-flow fan 

iCON 60 -150mm mixed-flow fan 

The iCON range can be used as a simple extract fan oper-

ated  by  a  remote  switch  (standard)

, or can be fitted with 

an  internal  control  module  to  give  a  range  of  control  options 

(which  includes:  timer,  humidity,  motion  sensor,  pull  cord  or 

combinations of these functions).  

These  optional  modules  are  available  separately  and  can  be 

fitted at the time of installation or retrofitted (see page 15).  

All  electrical  installation  must  be  carried  out  by  an  approved 

electrician  in  accordance  with  Approved  Document  Part  P  of 

U.K.  Building  Regulations  and  to  the  latest  IET  standards,  or 

the appropriate regulations in the country of installation.  

The fan requires a 230V 50Hz single phase supply, class II 

equipment

 (marked as stated in BS EN 60417). An external 

3A fuse and a 30mA RCD is required for each fan unit.  

The  iCON  230V  fan  range  is  IPX4  rated  and  therefore  it  is 

suitable  for  mounting  in  bathrooms  (incl.  zones  1  and  2),  toi-

lets, kitchens and utility rooms, as long as it is not exposed to 

water jets (i.e. can be installed 

above fixed shower head

).  

All wiring and switches for fans shall be selected and sited in 

accordance with BS7671 (IET Wiring Regulations) or relevant.  

Important 

Do not place the ventilator near direct heat sources, e.g. radi-

ant heaters,

 

or where temperatures can exceed 40°C (104°F). 

Wiring with no control module fitted:

 

Recessing fans in the wall 

The 

iCON  15

  requires  a  110mm  diameter  hole  through  the 

wall lined with a 100mm internal diameter duct. 

The 

iCON  30

  requires  a  110mm  diameter  hole  through  the 

wall,  counter  bored  160mm  to  a  depth  of  80mm.  The  hole 

should be lined with a 100mm internal diameter duct.  

The 

iCON  60

  requires  a  160mm  diameter  hole  through  the 

wall,  counter  bored  190mm  to  a  depth  of  80mm.  The  hole 

should be lined with a 150mm internal diameter duct. 

Surface mounting fans on the wall 

When  surface  mounting  the  iCON  30  and  iCON  60  the  sup-

plied mounting skirt should be used. 

The 

iCON  30 

requires  a  110mm  diameter  hole  through  the 

wall lined with a 100 mm internal diameter duct. 

The 

iCON  60 

requires  a  160mm  diameter  hole  through  the 

wall lined with a 150 mm internal diameter duct. 

Ensure all vapour barriers are properly restored.  

Optional modules for iCON 230V 

Wiring for control modules with no external switching: 

Wiring for control modules with external switching: 

Wiring and installation of iCON modules can be also found in 
the Installation an Operation Guide included within the module 
packaging (optional, see www.airflow.com for details).  

iCON fans can be recessed in a wall or ceiling (iCON 30 and 

60 are also supplied with surface mounting kit). See pages 8-

10 for details.  

Always  ensure  free  running  of  the  fan  impeller  and  that  duct 

connections are not over tightened to the fan outlet spigot.  

Fix  the  sealed  grommet  supplied  into  the  cable  entry  hole. 

Pierce  the  grommet  to  allow  the  mains  cable  to  be  pulled 

through while maintaining the integrity of the seal.  

Airflow  Developments  recommends  that  rigid  ducting  is  used 

where  possible  instead  of  flexible  ducting,  this  will  ensure 

maximum performance.  

Before  carrying  out  the  installation  see  pages  11&12  for 

best practise recommendations.  

Important 

Precautions must be taken to avoid the back-flow of gases into 

the room from the open flue of gas or other fuel-burning appli-

ances. 

To remove front cover assembly, first make sure 

the  fan  is  off, 

isolated from the power supply 

and the 

iris shutter is fully 

closed

.  

1. Undo  the  locking  screw  at  the  bottom  edge  of  the  cover 

using a screwdriver.  

2. Rotate  the  cover  a  few  degrees  anticlockwise  until  it  clicks 

out from the fittings.  

3. Remove the cover by pulling it out.  

To refit the cover, reverse the above procedure. If when refit-

ting the front cover the iris stays open, remove the cover and 

don’t  attempt  to  refit  it  for  approx.  two  minutes  (allowing  the 

actuator to retract back in the closed position). Then try again.  

80000437 Issue 1 06/18 

Model 

iCON 30 (R) 

225 

144 

101 

97 

43 

51 

20 

30 

148 

iCON 30 (S) 

225 

144 

92 

97 

29 

iCON 60 (R) 

280 

165 

110 

148 

55 

38 

20 

52 

177 

iCON 60 (S) 

280 

165 

80 

148 

46 

Model 

iCON 15 

197 

108.5 

67.5 

100 

40 

Page 3 of 16 

Range overview 

Part no. 

Model 

Air flow 

[l/s / m

3

/h] 

Power 

[W] 

Current 

[A] 

Noise level 

[dB(A) @ 3m] 

72683501 

iCON 15 

19 / 69 

9.4 

0.05 

28.8 

72591601 

iCON 30 

32 / 117 

26.4 

0.17 

33.3 

72591701 

iCON 60 

78 / 280 

66.3 

0.45 

41.6 

Page 4 of 16 

Electrical installation 

Electrical installation 

Page 5 of 16 

Page 6 of 16 

Mechanical installation 

Module clip 

Cable entry 

Cable clamp 

Module 

locating block 

Module fitting 

place 

Front cover removal 

iCON 15 

iCON 30 & 60 

Page 7 of 16 

Page 8 of 16 

Fitting on the wall 

iCON 15 

iCON 30 (R) 

iCON 60 (R) 

Terminal  

connector 