iCON SELV Fan Range Available Modules 

 

Page 2 of 8

 

Page 3 of 8

 

Electrical installation

 

Page 4 of 8

 

Mechanical installation

 

Airflow iCON SELV 12V fans can be controlled by optional 

control modules. For the SELV 12V range you can choose 

between six modules. 

 

* For blister pack add 

B

” 

at the end of part number. 

 

 

 

 

SAFETY FIRST: ALWAYS ISOLATE THE FAN 

UNIT FROM THE POWER SUPPLY BEFORE  

DOING ANY WORK ON THE FAN/MODULE.

 

All electrical installation work to be carried out by an ap-
proved competent person in compliance with U.K. Building 
Regulations and to the latest IET standards, or the appropri-
ate regulations in the country of installation. (for fan installa-
tion see the iCON SELV 12V Fan Range Installation and 
Operating Guide). 

 

Diagram A

 

-

 module wiring with no external switching 

(module functionality / pull cord activation only): 

 

 

Diagram B

 

-

 module wiring with external switching (live 

trigger connection used):

 

To install the module in an iCON fan follow the instructions 

below. See page 5 

-

 8 for instructional drawings.  

 

1.

 

Remove the iCON fan front cover (see page 5). 

 

2.

 

Lift the fan electrical terminal away from its mounting pillars 

and position on the module connector pins. Tighten the two 

screws with a suitable screwdriver. Ensure the leads are 

under the module retaining cable clamp. 

 

3.

 

Fit the module at a slight angle into the fan housing, ensur-

ing that the locating slot is fully engaged in to the locating 

block on the fan. 

 

4.

 

Push the module against housing, ensuring the module clip 

holds it in place (clicks at the cable clamp). With iCON 15 

& 30 the terminal will reposition back over mounting pillars. 

 

Modules with pull cord: 

Ensure that the pull cord is properly 

located within the cord slot at the bottom of the fan.

 

Modules with PIR control: 

Remove the oval logo cap fitted 

at the bottom of the front cover of the fan. Replace it with 

translucent lens supplied with the PIR module. Note: The 

lens must be replaced in order for the PIR module to function 

properly. Ensure the orientation of the lens is correct (i.e. the 

lens should be flush with the surface). 

 

Connecting mains cable into the module

 

Connect the 12V Power Supply Unit cable to the 3

-

way sup-

ply connector block (see wiring diagrams on page 3) ensur-

ing that the supplied cable clamp is fitted. Refit the front 

cover.

 

Note:

 When using DTS module on initial connection the fan 

will start immediately and continue running for the duration 

set on the timer function of the module.

 

Certificate No. FM 00152

 

BS EN ISO 9001:2015

 

Certificate No. EMS 569454

 

BS EN ISO 14001:2015

 

Part no.*

 

Model

 

Description

 

W

iri

n

g

 

d

ia

g

ra

m

 

72573603

 

PCS

 

Pull cord

 (Manual on/off) 

 

A

 

72574204

 

PCTS

 

Pull cord timer

 (Pull cord, Run on timer 1 

-

 30 min)

 

A, B

 

72682307

 

DTS

 

Delayed timer

 (Pull cord, 2 min delay, Run on timer 2 

-

 45 min)

 

A, B

 

72574202

 

HTS

 

Humidity timer

 (Pull cord, Run on timer 1 

-

 30 min, 40 

-

 90% RH)

 

A, B

 

72574203

 

PRTS

 

PIR timer

 (Motion sensor, Run on timer 

1

 30 

min, 40 

-

 90% RH) 

 

A, B

 

72574201

 

PRHTS

 

PIR humidity timer

 (Motion sensor, Run on timer 1 

-

 30 min, RH 

40 

-

 90%)

 

A, B

 