background image

 

 

AV100B   – 9041085 
AV100T   – 9041086 
AV125B   – 9041087 
AV125T   – 9041088 
AV150B   – 9041089 
AV150T   – 9041090 

Fan dimensions 

Page 2 of 16 

Page 3 of 16 

Page 4 of 16 

Range overview 

Aventa In-line Mixed Flow fans are available in 3 model 
sizes with or without timer function and have 2 speeds. 
Aventa In-line Mixed Flow fans can be used as a simple    
extract or supply fan where high pressure and flow rates 
are required. They can be mounted vertically with a 
condensation trap fitted or horizontally. The range has 
been designed to accept standard ducting sizes. The 
main body of the fan (1) is detachable from the inlet and 
outlet spigots and mounting assembly via the 2 clamps 
(6). (See diagram below). 

Page 5 of 16 

Page 6 of 16 

Page 7 of 16 

Mechanical installation 

Determine the orientation of the fan airflow direction by 
the use of the flow direction arrow on the fan body (1). 
(See diagram on page 3). 
Remove the fan body by releasing the 2 clamps (6). Using 
the mounting base as a guide mark and drill 4 holes. Use 
the wall plugs and screws provided and secure the 
mounting  base to the mounting surface. Insert the fan 
body (1) and secure with the retaining clamps (6). (See 
diagram on page 3). 
Connect the appropriately sized ducting to the spigot 
ducts. Airflow Developments Ltd recommends that rigid 
ducting is used instead of flexible ducting, this will help to 
ensure maximum performance.  
 

Type

 

Air flow,  

m

3

/h

 

Current,  

Amps

 

Power,  

Watts

 

Noise 
level,

 

db(A) @ 

3m

 

AV 100/T

 

145/187

 

0.11/0.21

 

21/33

 

27/36

 

AV 125/T

 

220/280

 

0.18/0.27

 

23/37

 

28/37

 

AV 150/T

 

405/520

 

0.17/0.27

 

30/60

 

33/34

 

Fan specification 

Electrical installation 

The Aventa In-line Mixed Flow range is IPX4 rated and is 
suitable for mounting in Zone 2 in bathrooms, toilets, 
kitchens, utility rooms when installed with a 30mA RCD. 
The fan requires a 230V 50Hz single phase supply. Class II 
equipment. BS EN 60417. An external 3A fuse is required 
for each fan unit. Cable sizes (max): Fixed flat wiring 2 
core 1mm

2

, 3 core 1/1.5mm

2

. All electrical installation to 

be carried out by an approved electrician in accordance 
with Part “P” U.K. Building Regulations and to the latest 
IEEE standards, or the appropriate regulations in the 
country of installation. 

Important 

The Aventa In-line Mixed Flow fan range is IPX4 rated and 
complies with the requirements of the EU norms and 
directives. Do not place the fan unit near direct heat 
sources, e.g. radiant heaters,

 

or where temperatures can 

exceed 40°C (104°F). 
Precautions must be taken to avoid back flow of gases in 
rooms with open flue fuel burning appliances. 
 

Page 8 of 16 

80000434 Issue 1 04/16

 

Aventa In-line  
Mixed Flow 

230V Fan Range 
Installation and Operating Guide 

Electrical installation 

AV100B, AV125B 

Min Speed 

Max Speed 

Min/Max Speed 

AV150B 

Min Speed 

Max Speed 

Min/Max Speed 

AV100T, AV125T, AV150T 

Min Speed 

Max Speed 

Electrical installation 

Electrical installation 

Отзывы: