Table 2
Table 3
Overall dimensions
The fan has four ventilation modes:
1. Standby mode
-
standard operation mode for the fan in case of no signalling from the sensors or external switch.
In standby mode the fan does not run.
2. 24 Hours
-
the fan runs at low speed for minimum round
-
the
-
clock ventilation. As humidity level increases, the fan switches
to MAX mode (by default) or to SILENT mode. The fan switches to SILENT mode when the motion sensor is activated or
external switch is closed.
3. SILENT
-
silent operation mode of the fan. This mode is may be activated by the motion sensor, external switch or humidity
sensor. For humidity sensor, this mode may be activated from the fan.
4. MAX
-
humidity
-
activated operation mode. It is switched on as humidity level increases.
This mode is activated for the humidity sensor by default.
Aura Smart HT/
MSHT
100
24 Hours
33
17
Aura Smart MSHT
+
Aura Smart HT
152
206
29 28
100/125
4
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Silent
72
22
Max
106
31
125
24 Hours
40
17
Silent
83
21
Max
133
32
33
72
82
40
83
97
-
33 ... 72
72 ... 106
-
40 ... 83
83 ... 133
+
+
Model
Speed
Spigot
dia.
Noise level at 3m
[dBA]
Max. air capacity
3
[m /h]
Functions
Humidity
control
24 Hour
Speed
control
Interval
ventilation
External
switch
Motion
sensor
Off
-
delay
timer
Turn
-
on
delay timer
Air capacity,
3
factory settings [m /h]
Air capacity
3
regulation range [m /h]
Model
Pause
Содержание Aura Smart
Страница 23: ...23 ...