background image

INSTALLATION AND OPERATING INSTRUCTIONS

Aura Smart

Innovative Low Energy Axial Fan

80000178 Issue 1-01/14

Содержание Aura Smart

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Aura Smart Innovative Low Energy Axial Fan 80000178 Issue 1 01 14 ...

Страница 2: ...ct operation by the person s responsible for their safety Do not leave children unattended and do not let them play with the product Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fue...

Страница 3: ...125 mm 1 pce 6 Screws and dowels 4 pcs 7 User s manual 1 pce DESCRIPTION Due to constant improvements the design of some models may slightly differ from that one described in this manual The product described herein is the axial fan made of high quality plastic designed for extract ventilation of small and medium sized residential premises that are heated during winter period Table 1 3 Recycle at ...

Страница 4: ... by the motion sensor external switch or humidity sensor For humidity sensor this mode may be activated from the fan 4 MAX humidity activated operation mode It is switched on as humidity level increases This mode is activated for the humidity sensor by default Aura Smart HT MSHT 100 24 Hours 33 17 Aura Smart MSHT Aura Smart HT 152 206 29 28 100 125 4 Silent 72 22 Max 106 31 125 24 Hours 40 17 Sile...

Страница 5: ... used to facilitate mounting The fan is equipped with a removable grille Press the latches slightly to release the grille from the front cover While installing the grille on the front cover back match the latches and respective slots in the cover and insert to click The pointer on the reverse side of the grille must be directed to the shorter side close to the hole 100 125 5 ...

Страница 6: ...QF QF The fan casing has three round lowered tabs for cable entry Cut out a hole at the most suitable place with a knife FAN MOUNTING SEQUENCE 6 4 5 6 1 2 3 ...

Страница 7: ...ns by four wiring diagrams The fan is compatible with 100 240 V 50 60 Hz power mains The Aura Smart MSHT has Li terminal for connection to the lamp up to 200W 230 V or 100 W 120 V At this connection the fan will be switched on signal from the motion sensor ...

Страница 8: ...evel increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode 8 N N L L LI LI LT LT L L N N Standby mode fan does not run or 24 Hours mode 3 fan operated at 40 33 m h Turn on delay timer starts 0 2 5 min Humidity change Motion sensor is activated MAX SILENT mode is activated Fan operation in Silent mode Signal to LI terminal lig...

Страница 9: ...on in SILENT mode if adjusted by the user After humidity level drops to standard level the fan reverts to SILENT mode LI LI LT LT L L N N N N L L Fan operates 3 83 72 m h MAX 3 40 33 m h MAX at air flow Humidity change Motion sensor is activated MAX SILENT mode is activated Fan operation in Silent mode Humidity stabilization Motion if off Signal to LI terminal light is on Humidity extraction timer...

Страница 10: ...e After no motion is detected the fan reverts to standby mode As humidity level increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode 10 LI LT L N S N L Standby mode fan does not run or 24 Hours mode 3 Fan operates at 40 33 m h Humidity change Motion sensor is activated MAX SILENT mode is activated Fan operation in Silent mod...

Страница 11: ... Aura Smart MSHT only the fan switches to SILENT mode After no motion is detected the fan reverts to standby mode As humidity level increases the fan switches to MAX mode by default or to SILENT mode After humidity level drops the fan reverts to standby mode Standby mode fan does not run or 24 Hours mode 3 Fan operates at 40 33 m h Humidity change Motion sensor is activated MAX SILENT mode is acti...

Страница 12: ...n on delay time 0 min off delay time 5 min humidity extraction time 30 min motion sensor for iFan Move is included 12 FAN OPERATION INDICATION The fan is turned on by the motion sensor or external switch the light indicator STATUS is green The fan is in standby mode the light indicator STATUS blinks green once in 2 seconds Fan operation in 24 Hours mode the light indicator is red Fan operation in ...

Страница 13: ...Silver colours provide high signal conductivity from the remote controller and do not influence the signal transferability The covers of Graphite Mauve or Black may suppress the signals To avoid this please remove the front cover during adjustment operations After each signal reception the fan sends an acoustic signal to confirm the setting adjustment In case of no acoustic signal from the fan try...

Страница 14: ...or 4CP once To display the current air capacity on the remote controller press the buttons 5RC HUMIDITY EXTRACTION MODE SELECTION By default the extraction mode is MAX mode To select the humidity extraction mode Press the button 1CP on the control panel in cycles Press the button 2RC for Silent or 3RC for Max on the remote controller Max active humidity response mode with the best impeller perform...

Страница 15: ...ss and hold the button 7CP and press the button 2CP in cycles on th control panel This adjustment is not available from the remote controller Press and hold the button 7CP and press the button 2CP on the control panel once to display the current settings of the humidity sensor timer OFF DELAY TIMER ADJUSTMENT The default time is 5 minutes When the motion sensor is activated or the external switch ...

Страница 16: ... button 2CP in cycles on the control panel Press the buttons 8RC 0 2 or 5 respectively on the remote controller Press and hold the button 5CP on the control panel and then press the button 2CP once to display the current on delay timer setting SWITCHING MOTION SENSOR FOR IFAN MOVE MODEL The motion sensor is off by default The light indicator Status under the button glows when the motion sensor is ...

Страница 17: ... button 7RC once again EXTRA FUNCTION SWITCHING FAN ON OFF This function may be controlled from the remote controller only If the fan is switched off with the button 1RC on the control panel the light indicator on the fan goes off and the fan does not response to any external functions temperature or humidity fluctuations motion registration or activation by the external switch The interval ventil...

Страница 18: ...ithin 5 seconds until the light under the button stops blinking green 18 Push MAINTENANCE Disconnect the fan from power mains prior to any maintenance operations Maintenance means periodic clearing of the fan surfaces from dust and dirt To clean the fan use a soft cloth wetted in a water soap solution Wipe the surfaces dry after washing Avoid liquid splashes on the motor and the circuit board The ...

Страница 19: ...s original package Store the delivered product in the manufacturer s original packing box in a dry ventilated premise with the temperature range 0 0 from 5 C up to 40 C and relative humidity less than 80 The storage environment must not contain dust acid or alkali vapours that may cause corrosion of the product parts ...

Страница 20: ...of the Manufacturing company within the warranty period service life the customer shall have the right to elimination of the manufacturing defects by means of warranty servicing performed free of charge The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product by the customer The defects are eliminated eit...

Страница 21: ... to the product in case of force majeure fire flood earthquake war hostilities of any kind blockade in case of absent seals provided such seals are prescribed by the User Manual or other relevant substituting document in case of unavailable warranty card in case of unavailable payment document to confirm the purchase with indication of the sale date The manufacturing company shall be responsible f...

Страница 22: ...2 Airflow Developments Ltd Aidelle House Lancaster Road Cressex Business Park High Wycombe Bucks HP12 3QP United Kingdom Tel 44 0 1494 525252 Fax 44 0 1494 461073 E mail info airflow com Web airflow com ...

Страница 23: ...23 ...