Introduction

 

This Service Instructions are combined with technical specification, operating 
guide and specification for the “Aura-eco ” fan; it contains information on 
installation, that are important for ensuring correct and safe operation of the fan. 

 

Designation

 

 

Fans  are  designed  for  ventilation  of    domestic  and  similar  premises 
(apartments,offices,stores,garages,kitchens,  bathrooms,  toilets  and  other 
rooms, heated in wintertime). 
Fans are exhaust fans and are designed for wall or ceiling mounting (Fig.6,7). 
They are designed for a long-duration operation, without disconnection from 
the power network. 
The fan design is being constantly improved therefore some models may 
slightly vary from those described in the present specification. 

 

Set of supply

 

The following article is included: 
- Fan  1pc; 
- User's manual; 
- Screws 4 pcs. 
- Packing box 

 

The fan arrangement with the timer or with a timer and a humidity sensor is 
shown at the Fig. 1 

 

 

3

 

1

 

5

 

 

 

4

 

 

 
 

Fig.1

 

 

1-cover, 2-casing, 3-electric motor 
 4-blade impeller, 5-timer. 
 

 

Содержание Aura-eco

Страница 1: ...9041411 INSTALLATION OPERATING INSTRUCTIONS Aura eco 100mm 150mm Axial Fans ...

Страница 2: ...r rooms heated in wintertime Fans are exhaust fans and are designed for wall or ceiling mounting Fig 6 7 They are designed for a long duration operation without disconnection from the power network The fan design is being constantly improved therefore some models may slightly vary from those described in the present specification Set of supply The following article is included Fan 1pc User s manua...

Страница 3: ...d connection dimensions are listed in the tables 2 3 and at the Fig 1 2 The fans are designed for the connection to the AC network with the voltage of 220 240 V and current frequency of 50 Hz Table 2 Max air intake m 3 h Max pressure Pa Nominal power W Noise level dBA 60 35 6 26 235 86 20 35 The fans are designed for use in the premises with temperature from 0 C to 45 C The fans do not interfere w...

Страница 4: ...Table 3 Type Dimensions mm Weight kg a b c d e Aura eco air 100 150 122 102 100 17 0 56 Aura eco air 150 205 174 124 150 19 0 9 Overall and connection dimensions Fig 2 1 1 Timer with motion sensor Fig 3 ...

Страница 5: ...ork connections to fan spigot Precautions must be taken to avoid the black flow gases into the room from the open flue of gas or other fuel burning appliances PREPARATION OF DEVICE OPERATION Attention All work must be carried out with the equipment fully isolated from the power supply The electrical connection is to be carried out in accordance with the relevant wiring diagram and are only to be d...

Страница 6: ... switch Diagram of the connection of Aura eco fan with timer timer with humidity sensor with built in switch connection of Aura eco fan 100 150 B L LT N connection of Aura eco fan 100 150 T HT L N Diagram of the connection of Aura eco fan with timer timer with motion sensor without built in switch connection of Aura eco fan 100 150 PRT L LT N ...

Страница 7: ... exceeded After the voltage is 60 H min H max 90 H extreme right position T H Fig 5 2 disconnected or humidity level H is decreased the fan continues working during the time set by timer T which is regulated from 2 till 30 min The options of time T and humidity H are regulated by turning the potentiometers T and H clockwise to increase and anticlockwise to decrease the delay time and humidity leve...

Страница 8: ...Fig 6 Fig 7 ...

Страница 9: ...Fig 8 Fig 9 ...

Страница 10: ...Fig 10 ...

Страница 11: ...ply 3 Has not been subjected to misuse neglect or damage 4 Has not been modified or repaired by any person not authorised by Airflow Development Ltd 5 Has been installed in accordance with Building Regulations IEE wiring regulations Airflow Developments shall not be liable for any loss injury or other consequential damage in the event of a failure of the equipment or arising from or in connection ...

Отзывы: