Fan adjustment - Humidity / Timer 

Humidity and timer functions are activated when the 
voltage is supplied to the Ls terminal via an external 
switch or when the humidity level rises above the set %
RH level (adjustable between 60 and 90% RH). 
After the voltage to the Ls terminal is disconnected or 
the humidity level falls below the set %RH level, the fan 
continues to run for the set overrun period between 2 
and 30 minutes. 

The humidity level is adjusted 
by turning the potentiometer 
(

H

) clockwise to increase and

anti-clockwise to decrease. To
set the maximum humidity
level the potentiometer (

H

)

has to set at the max position
(90%).
See page 8 “Fan adjustment -
Timer” for timer adjustment
instructions.

 

H

 

 

Page 9 of 16 

T

 

Through the wall i

nstallation with flexible

ducting 

To maximise airflow rigid ducting should be used. 

Where flexible ducting is used the diameter must be     
maintained and it is good ventilation practice that the 
ducting is extended to 90% of its possible length in 
order to maintain the best possible airflow. Ensure 
that flexible duct connections are not over tightened to 
the fan outlet spigot. The fan and ducting should be 
installed in accordance with the requirements of the 
Domestic Ventilation Compliance Guide, part of the 
Building Regulations.  

1. Has been installed and used in accordance with the
fitting and wiring instructions supplied with each unit.
2. Has not been connected to an unsuitable electrical
supply.
3. Has not been subjected to misuse, neglect or
damage.
4. Has not been modified or repaired by any person not
authorised by Airflow Developments Ltd
5. Has been installed in accordance with latest Building
Regulations and BS7671 wiring regulations by a
recognised competent installer.
Airflow Developments Ltd shall not be liable for any
loss, injury or other consequential damage

in the event

of a failure of the equipment or arising from, or in
connection with, the equipment excepting only that
nothing in this condition shall be construed as to
exclude or restrict liability for negligence.

This warranty does not in any way affect any statutory or 
other consumer rights. 

 

Recommended Best Practice 

The Building Regulations 2010, Statutory Instrument 
Part 9, paragraph 42, imposes a requirement that 
testing and reporting of mechanical ventilation 
performance is conducted in accordance with an 
approved procedure. 
Compliance with this requirement by an assessed and 
registered ‘Competent Person’ should follow a ‘Best 
Practice’ process and adopt air flow measurement, 
Method A – The Unconditional Method – using a 
suitable UKAS certified measuring instrument.  
Generically referred to as a ‘Zero Pressure Air Flow 
Meter’ or ‘Powered Flow Meter’. 
Further information on this method is detailed in NHBC 
Building Regulations Guidance Note G272a 10/13 and 
BSRIA ‘A Guide to Measuring air flow rates’ document 
BG46/2015 

Maintenance 

SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT 
FROM THE POWER SUPPLY BEFORE REMOVING 
THE COVER.  
When installed according to these instructions the Aria 
range is completely safe. The materials used do not 
constitute a hazard.  

Cleaning 

 

The external housing of the fan can be wiped with a 
damp cloth. Do not use household cleaners containing 
abrasives. 

Note: 

Always  isolate the fan when cleaning. Never 

clean any parts of the fan assembly by immersing in 
water or using a dishwasher.   

Warning 

This appliance can be used by children aged from 8 
years and above and persons with reduced physical, 
sensory or mental capabilities or lack of experience 
and knowledge if they have been given supervision or 
instruction concerning use of the appliance in a safe 
way and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without 
supervision  

Fan adjustment - Motion sensor / Timer 

The fan with motion sensor and timer function switches 
on when movement is detected between a distance of 
1 and 4 metres from the fan. The sensor has a 
detection angle of 100° horizontally. 

Once movement ceases, the fan continues to run for 
the set overrun period which is adjustable between 2 
and 30 minute. 

UK Head-Office 

AIRFLOW DEVELOPMENTS Limited 
Aidelle House, Lancaster Road 
Cressex Business Park 
High Wycombe 
Buckinghamshire  
HP12 3QP 
United Kingdom 

Tel:   

+4 (0) 1494 525252

Email:    [email protected] 
Web:     airflow.com 

Czech Republic 

AIRFLOW LUFTTECHNIK GmbH

 

organizační složka Praha

 

Hostýnská 520

 

108 00 Praha 10

 

Czech Republic

 

Tel:     +42 (0) 2 7477 2230
Fax:     +42 (0) 2 7477 2370
Email:    [email protected]

 

Web:     airflow.cz

 

Germany 

AIRFLOW LUFTTECHNIK GmbH

 

Postfach 1208

 

D

-

53349 Rheinbach

Germany

Tel:   

 +49 (0) 222 69205 0

Fax:     +49 (0) 222 69205 11
Email:    [email protected]

 

Web:     airflow.de

 

AIRFLOW DEVELOPMENTS LTD reserve the right  in the interest of continuous development to alter any or all specifications without 
prior notice.

 

Page 10 of 16 

Page 11 of 16 

Warranty 

Applicable to units installed and used in the United 
Kingdom. Airflow Developments Ltd guarantees the 
Aria for 

2

 years from date of purchase against faulty

material or workmanship. Warranty only covers the fan, 
not the reinstallation of this if required. In the event of 
any defective parts being found, Airflow Developments 
Ltd reserve the right to repair or at our discretion 
replace without charge provided that the unit:  

Page 12 of 16 

Page 13 of 16 

Page 14 of 16 

Page 15 of 16 

Page 16 of 16 

Fan Assembly - Motion sensor 

Fan body 

assembly

 