Continuous Ventilation

Installation and Operating Guide

TM

iCONstant T    - 72687117

iCONstant HT - 72687118

 Model

A

B

C

D

E

 iCONstant 

197

120

70

100

50

Function

1

2

3

4

5

6

7

8

Delayed 

start

0 seconds

OFF

Delayed 

start

2 minutes

ON

Timer

2 mins

OFF OFF

Timer

15 mins

OFF ON

Timer

30 mins

ON OFF

Timer

45 mins

ON

ON

Humidity

50-60%

OFF OFF

Humidity

60-70%

OFF ON

Humidity

70-80%

ON OFF

Humidity

80-90%

ON

ON

Flow rate

OFF

OFF OFF

Flow rate

6 L/s

OFF ON

Flow rate

8 L/s

ON OFF

Flow rate

13 L/s

ON

ON

Flow sensor

ON

ON

Flow sensor

OFF

OFF

TL

N

RCD

N

L

3 AMP

SWITCHED FUSE

3 POLE FAN 

ISOLATOR

2 POLE FAN 

ISOLATOR

L

N

LS

TL

N

RCD

N

L

3 AMP

SWITCHED FUSE

For control with

external switching

N - Neutral

L - Live

T - Tigger

N - Neutral

L - Live

For control with no

external switching

TLN

ON

OFF

ON

OFF

A

E

D

A

C

B

Fan overview

Electrical Installation

Installation

Prepare wall or ceiling

Access to the electronics

Dip switch functions

Fan Dimensions

The iCONstant range consists of timer and humidity/timer 
variants. They are designed for use in any wet room. Trickle 
flows rates of 6, 8 or 13 l/s can be activated on installation. 
Boost flow rates are selected by pull cord, external switch 
or humidity sensor (HT model only). The iCONstant range is 
IPX5 rated and suitable for use in Zone 1 of a wet room.

Secure supply wires into the terminal block. L—Live, 
N-Neutral and T—switched live (optional). Secure AC mains 
cable to main body of fan with cable clamp supplied.

Fit back plate cover.  
1. Locate back plate cover on to main body assembly. 
2.  Twist back plate cover clockwise until locked. (Arrow 

should be in the 12 o’clock position). 

3. Secure back plate cover with fixing screw.

All electrical installation to be carried out by an approved 
electrician in accordance with Part “P” U.K. Building 
Regulations and to the latest IEEE standards, or the 
appropriate regulations in the country of installation. 
iCONstant fans require a 90-264V 50/60Hz supply, it is 
double insulated so therefore does not require an earth. 
Fans installed in Zone 1 or Zone 2 must be at least IPX4 
(splash proof) rated. Additionally, fans installed in Zone 1 
must be SELV (Safety Extra Low Voltage) or IPX5 (jet proof) 
rated. The iCONstant range is IPX5 rated and suitable for 
use in Zone 1.

Remove back plate cover.
1. Remove screw at base of back plate cover. 
2. Twist back plate cover anticlockwise. 
3. Lift away.

Mount fan into the spigot hole ensuring cable is fed through 
the cable grommet provided. Position alignment arrow 
vertically. Fix to wall or ceiling with the 4 screws provided. 

Description of electronic controls.

Dip Switch factory settings highlighted above.

Remove front cover.
1. Twist anticlockwise and 2. Lift away.

Using the template provided, mark and drill a spigot hole to 
suit 100mm diameter rigid ducting. Make provision for the 
electrical supply cable. Fit wall plugs provided.

Remove electronics cover.
1. Undo the 2 fixing screws, 
2. Lift off electronics cover.

Front Cover

Alignment Arrow

Increase airflow

Alignment arrow

Humidity sensor

(HT model only)

Decrease airflow

Info LED

Function

Dip Switches

1

1

1

2

2

2

3

3

Back Plate Cover

Main Body

Electronics Cover

80000343 Issue 1 04/15