4
OPERATING THE FAN
The fan can be operated at different speeds by pulling the three-speed switch using the pull cord:
-
First pull: HIGH speed
-
Second pull: MEDIUM speed
-
Third pull: LOW speed
-
Fourth pull: OFF
FAN ROTATING DIRECTION SWITCH
The switch on the fan controls the direction of rotation. This changes the direction of air movement:
-
In cold weather: Push the switch “up” so that the fan will circulate the warm air trapped near the
ceiling to move downwards throughout the room.
-
In hot weather: Push switch “down” so that the fan will create a breeze and circulate the air to
the room.
CLEANING
Risk of injury:
Before cleaning the fan, always switch off the power at the main circuit breaker and
wait until the fan has come to a complete stop.
Clean the fan with a dry or damp soft cloth. Do not use any liquids or detergents.
DISPOSAL
Disposal of the fan:
You are required to dispose of electric and electronic appliances separately from
your household waste. Please inquire at your municipality regarding proper ways of disposal.
By separately disposing of your electric and electronic appliances, you are participating in recycling and
you are helping to prevent potentially toxic substances from polluting the environment.
Disposal of the packaging:
The packaging consists of cardboard and marked plastic and Styrofoam
which can be recycled. Please recycle.
MALFUNCTIONS
– TROUBLE SHOOTING
Risk of injury:
Inappropriate repairs can lead to the fan not functioning safely. This can cause a
hazard for yourself and your environment.
Please check the following table before contacting your retailer:
Malfunction
Underlying cause (error)
Solution
Fan does not turn.
Fan switched off?
Switch on fan.
No mains voltage?
Check circuit breaker.
Wiring connected incorrectly?
Check steps 4 and 5 to ensure
wiring connected correctly.
Fan vibrates.
Fan not installed properly?
Install fan thoroughly according
to installation instructions.
If you cannot resolve the malfunction yourself, please ask your retailer directly.
Please note that the warranty will be voided by inappropriate repairs.
TECHNICAL DATA
Speed
Voltage
Power
RPM
III
230V ~ / 50Hz
60W
285
II
53W
230
I
53W
130
MANUFACTURER
Vaxcel International Co., Ltd.
121 E North Avenue, Carol Stream, IL, USA
www.vaxcel.com