Sandpiper Installation Guide  

 28

th

 May 2013 – Revision 7 

Page 

7

 of 

22

 

 

Figure 4-If the filter of the Sandpiper is placed on the opposite 

side of the return air grille then the air passage MUST remain 

unobstructed 

Contact Aircommand if your installation differs significantly 
from that prescribed above. 

1.

 

Cut vent holes 

WARNING 

There may be electrical wiring located between the floor 
and inside the walls. Ensure that power is properly 
disconnected at the supply (mains and/or battery). Failure 
to do so may result in personal injury or death.

 

Floor cut-out 

 

When  positioning  the  unit  remember  that  you  will 
need  to  get  either  a  drill  or  long  handled  screwdriver 
into  the  cupboard/bed  area  to  secure  the  hold  down 
screws onto the floor 

 

Mark  out  the  holes  in  the  floor  using  the  template 
found  at  the  end  of  this  manual,  also  mark  out  the 
corners/edges  of  the  unit  so  that  the  unit  can  be 
positioned correctly 

 

Cut out the holes in the RV floor  
 

Do  not  cover  the  cut  outs  with  chicken 
wire/mesh  or  similar,  doing  so  may  void  the 
warranty.  There  are  already  grilles  built  into  the 

bottom of the unit. 

 

 

Figure 5-Floor cut outs 

 

Place  the  Sandpiper  so  that  the  edges  of  the  unit line 
up  with  the  edges  marked  from  the  template,  secure 
the unit using the six hold down screws supplied  
 

Cupboard/seat/bed cut out 

 

Determine  where  the  return  air  grille  will  be  placed 
according to the requirements above  

 

If  you  are  using  the  supplied return  air grille  then  the 
cut-out  template  can  be  found  at  the  end  of  this 
installation manual 

 

Ensure  the logo  at  the  top  of  the  return  air  grille  is in 
the correct orientation 

 

Cut out the required hole and secure the grille in place 
using the supplied screws 

 

If  you  are  not  using  the  supplied return  air  grille  then 
the minimum size cut out is 345

cm

2

 (23cmx15cm) 

 

2.

 

Route and secure ducting 

Don’t  route  the  ductwork  near  any  heat 
producing  appliances  such  as  the  rear  of  a 
refrigerator  as  condensation  will  be  formed.  Do 

not have an outlet blowing air into the return air grille as 
this will ‘short circuit’ the unit. 

 

Attach  the  ducting  securely  to  the  unit  by 
pushing/twisting  the  ducting  onto  the  ducting  spigots 
until the teeth are engaged 

 

Attach  the  longest  piece  of  ducting  to  the  bottom 
ducting spigot

 

 

Screw  the  inner  duct  piece  onto  the  other  end  of  the 
ducting 

 

Figure 6-Inner duct piece shown on the left, outer duct piece 

shown on the right

 

 

Route  the  ducting  to  where  the  outlets  are  desired 
ensuring the bends are kept to a minimum and are as 
smooth  as  possible. 

It  is  recommended  that  the 

outlets are placed high up in the van and directed into 
areas  of  common  usage  (bed,  dining  table,  kitchen 
etc)

 

The  longest  single  piece  of  ducting  must  be  less 
than 6m and the overall length must be less than 
15m 

Содержание sandpiper

Страница 1: ...on Guide 28th May 2013 Revision 7 Page 1 of 22 SANDPIPER OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT MAINTENANCE SPECIFICATIONS OPERATING INSTRUCTIONS CUT OUT TEMPLATES SPARE PARTS WIRING DIAGRAM TROUBLESHOOTING GUIDE ...

Страница 2: ...n Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION RÉFRIGÉRÉE Garantie pour l Australie Nous nous engageons par cette garantie à faire rectifier gratuitement par notre agent de service tout défaut résultant d un défaut de fabrication ou de remplacer tout composant défectueux dans les 12 mois suivant la date du premier achat de l appareil au détail Cet en...

Страница 3: ...CTIONS FOR SANDPIPER AIRCONDITIONER Model Number 7000001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be installed by a qualified service technician Failure to properly install the unit or attempting to modify it in any way can be extremely hazardous and may result in property damage and persona...

Страница 4: ...ide the van Cook outside if possible Park the caravan RV in a shaded position In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly improve its ability to cope with the expected peak heat load III CONDENSATION In areas of high humidity the humid air within the van will cause sweating or condensation in parts of the unit as the humid...

Страница 5: ...rews are all the same type of screw BEFORE INSTALLATION Ensure that the installation instructions have been properly read and understood Installation must conform to local wiring regulations DO NOT attempt to modify or add components to the installation procedure This equipment must only be serviced by a licensed refrigeration mechanic If your installation varies from the method outlined please co...

Страница 6: ...n appropriate location the cable length from the unit to the touch screen is 4m Extension cables are available contact Aircommand if needed The filter side of the Sandpiper should face the open side of the seat bed where the return air grille is Figure 1 Figure 1 Preferred orientation of the unit where the filter is on the same side and close to the return air grille If this is not possible then t...

Страница 7: ...upplied Cupboard seat bed cut out Determine where the return air grille will be placed according to the requirements above If you are using the supplied return air grille then the cut out template can be found at the end of this installation manual Ensure the logo at the top of the return air grille is in the correct orientation Cut out the required hole and secure the grille in place using the su...

Страница 8: ...d or battery Failure to do so may result in personal injury or death Locate an existing wall socket and plug the unit in If the supply cord is damaged it must be replaced by Aircommand one of its service agents or similarly qualified persons in order to avoid a hazard With a flat head screw driver or similar pop off the rear cover of the interface Figure 7 Pop off the rear cover of the interface u...

Страница 9: ... similar WARNING Airborne particles can pose a health risk particularly to young children and the elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filter can be washed out using warm soapy water Care must be taken to avoid ripping the fabric The filter must be completely dry before reinstallation The filter should be cleaned e...

Страница 10: ... Page 10 of 22 If you have a claim please contact Aircommand directly on 08 8345 8444 alternatively you can fax 08 8243 0628 or email service aircommand com au please have your unit serial number ready which can be found on the sticker on top of the unit ...

Страница 11: ...A PTY LTD SANDPIPER MODEL NO 7000001 240V 50HZ REFRIGERANT 407C 450G RATED CAPACITY COOLING 2200W RATED CAPACITY HEATING 1800W POWER INPUT COOLING 980 W POWER INPUT HEATING 880 W RATED CURRENT COOLING 4 3A RATED CURRENT HEATING 3 8A MAX INPUT POWER 1150W MAX CURRENT 5A MAX DISCHARGE SUCTION PRESSURE 2800 kPa 700kPa PROOF RATING IPX4 AIR DELIVERY MAXIMUM 120 L s E OE All values are approximate subj...

Страница 12: ...nical parts which are protected by grilles but objects of a small enough size may be able to penetrate the inside of the appliance The remote control has the same features as the LCD touchscreen except for the timer function The button icons on the remote may vary slightly compared to the touchscreen LCD TOUCHSCREEN CONTROL PANEL Decrease Fan Speed On Off Mode Increase DAY TIME SETTING Press and f...

Страница 13: ...e is close to comfortable but you wish to dehumidify the air Cycle mode button to highlight the snowflake dripping icon Select desired set point temperature by pressing the plus or minus keys or Note the fan speed is locked in LOW The compressor will cycle on and off at approximate intervals of 6 minutes to extract moisture from the air AUTO The Auto mode is used when Turn unit ON Press MODE until...

Страница 14: ...e On Off will not be affected by the button lock TEMPERATURE DISPLAY SETTING Press and for 5 seconds to change temperature measurement unit to either or REMOTE CONTROL INSTRUCTIONS The functions on the remote control are the same as on the LCD touchscreen except that the timer function can only be set from the LCD touchscreen see Figure 11 for diagram The functions operate the same way if set by t...

Страница 15: ...me during timer clock setting Fan speed Select from High Medium and Low In cooling and heating mode AUTO FAN speed can be selected Mode COOL decrease air temperature DRY dehumidify the air HEAT increase room temperature AUTO automatically selects heat or cooling mode as required FAN circulates air Sleep Allows the controller to gradually depart from the set point temperature while you sleep Timer ...

Страница 16: ...Sandpiper Installation Guide 28th May 2013 Revision 7 Page 16 of 22 SANDPIPER FLOOR TEMPLATE ...

Страница 17: ...Sandpiper Installation Guide 28th May 2013 Revision 7 Page 17 of 22 ...

Страница 18: ...ter 3 6102092 Return air grille 4 5601069 Electronics kit inc touchscreen and remote 5 7001004 Thermostat switch 6 7001006 Top foam canopy Not shown 7001005 Outside fan assembly inc 3uF capacitor Not shown 5601071 Remote control only Not shown 7000001 Sandpiper unit without ducting Not shown 7001009 Buckles and straps all 3 included 7 N A Power cord and separate cable to interface 2 3 1 4 5 6 7 ...

Страница 19: ...Sandpiper Installation Guide 28th May 2013 Revision 7 Page 19 of 22 SANDPIPER WIRING DIAGRAM ...

Страница 20: ... sensor error E21 outdoor air temperature sensor error Contact Aircommand Australia for specialist advice on fault correction and access to our service agents Poor cooling or heating performance Return air filter is blocked Remove filter clean replace Clean filter every 2 weeks and more frequently with high use Air outlets are closed Ensure that at least 2 outlets are open highest capacity is avai...

Страница 21: ...ed RV is too large for the air conditioner The Sandpiper is intended to provide spot cooling and relief to certain areas immediately adjacent to the outlets it is not intended to lower the temperature in all areas of the RV It may do this in some cases but that will depend on the heat load of the van which is affected by size amount of windows insulation persons in the van direct sunlight etc Air ...

Страница 22: ...he caravan Unit has been installed incorrectly Refer to instruction manual for correct installation position Timer function does not work Timer function is attempting to be set from using the remote The timer function can only be set from the control pad it will not work if set by the remote refer to operating instructions for more information To display coil temperature a Press and for 3 seconds ...