background image

6.  Assess Roof Thickness

•  Measure the roof thickness and consult the table across to 

check if adjustments to the duct length are required. 

•  NOTE: If the duct length needs to be adjusted then cut the 

excess from the 

un-notched 

end.

  Roof thickness  Comment 

Duct length 

Bolt length

 (mm) 

 

(mm)

  25 

Absolute minimum – ring must be  

60 

Standard

   

removed from top of plenum ducting.  

  30 

Use plenum duct as provided 

65 

Standard

  40 

                          “ 

75 

Standard

  50 

                          “ 

85 

Standard

  60 

                          “ 

95 

Standard

  85 

                          “ 

120 

Limit of std bolt

  115 

Absolute maximum 

150 

Installer to provide

  General 

Roof less than 30mm – remove duct ring.  

Duct length =  

Roof greater than 85mm thick will

  rule 

30mm or thicker leave duct as supplied 

Roof thi 35mm 

require installer to provide longer bolts

7.  Assemble Duct

•  Thread a hold down bar onto the M8 

bolt and push the bolt almost all the 
way into the hole in each corner of 
the brace (Fig 9).

•  Leave a 10mm gap between the 

hold down bar and the recess in the 
plastic brace. This will allow for 
easier engagement with the four 
corresponding threaded holes in the 
unit.

•  Turn the assembly over and add the 

black plastic duct work to the top of 
the assembly with the notch 
upwards (Fig 10). The notch is shown 
circled below.

•  Align the notch with the inside fans 

power cable.

Note: 

Some installers fi nd it easier to 

attach the duct to the roof top unit fi rst 
and then insert the brace assembly.

         When attaching the duct to the 
unit take  care to ensure it forms a 
tight, unbroken seal that doesn’t allow 
cold air to escape.

Fig 10: Fit the black plastic duct onto the brace assembly ensuring a tight, sealed fi t.

Fig 9: Insert the four M8 bolts and hold down bars into the corners of the brace.

Содержание 5860001

Страница 1: ...hnician Failure to properly install the unit or attempting to modify it in any way can be extremely hazardous and may result in property damage and personal injury Aircommand will not be held responsible for problems relating to incorrect or improper installation methods INFORMATION INSTALLATION COMMISSIONING MAINTENANCE SPECIFICATIONS SPARE PARTS WIRING DIAGRAM TROUBLE SHOOTING OPERATING INSTRUCT...

Страница 2: ...Position the vehicle so that the annex will face north and protect the windows from direct radiation Turning off unneeded appliances that might increase the heat load inside the van Cook outside if possible Park the caravan RV in a shaded position if possible In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly improve its ability ...

Страница 3: ...o nation wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This equipment must only be serviced by a licensed refrigeration mechanic If your installation varies from the method outlined please contact Aircommand for specialty advice WARNING Failure to properly install the unit or attempting to modify it in any way can be extre...

Страница 4: ...5 from the horizontal and the rear of the unit should never be higher than the front when in use Contact Aircommand if your installation differs significantly The above outline on the left shows the minimum clearance required around the Sparrow Mk4 unit on the roof of the vehicle distances shown are calculated from a 14 square hole 356 x 356mm The above outline on the right shows the minimum clear...

Страница 5: ...battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Be sure to allow space for power cable The roof cavity must be framed to support the units weight 20mm min Longitudinals must be fixed securely to transverse roof members Fig 3 Shows an ideal roof structure with strong longitudinals and a 14 hole boxed Fig 5 Left hand picture...

Страница 6: ...h the corresponding holes on the weather collar Fig 6 Apply sealant around bolt holes and then position unit over the weather collar and set down gently 5 Connect Electrical Supply This unit MUST be installed in accordance with SAA Wiring regulations and in particular AS3001 2008 Refer Fig 7 for position of terminal block Connect electrical supply to terminal strip Note position of active neutral ...

Страница 7: ...7 Assemble Duct Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the hold down bar and the recess in the plastic brace This will allow for easier engagement with the four corresponding threaded holes in the unit Turn the assembly over and add the black plastic duct work to the top of the assembly w...

Страница 8: ...hten the four M8 bolts with the threaded inserts in the rooftop unit Recommended tightening torque of the bolts is 7 N m 5 2 lbf ft As the bolts are tightened ensure that the hold down bars slot into their recesses in the brace Fig 11 Fig 11 Raise the duct assembly up to the roof hole ensuring the black plastic duct work forms a tight fit around the evaporator fan underneath the unit Then engage t...

Страница 9: ...ements by pulling them out of the plenum and use the six self tapping counter sunk screws to secure the cover s edges to the caravan ceiling Fig 16 In some instances a very small pilot hole may need to be drilled to guide the screws into place Replace the filters by sliding them into the plenum until they click into place INSTALLATION IS NOW COMPLETE PROCEED TO COMMISSIONING Fig 13 Shows the posit...

Страница 10: ...rborne particles can pose a health risk particulalry to young children and the elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out using warm soapy water Care must be taken to avoid ripping the fabric The filters should be cleaned every two weeks or more when in use Prolonged use higher concentrations of...

Страница 11: ... 4kg Model number 5860001 Electrical rating 240V 50Hz Refrigerant 407C 450g Rated capacity cooling 2000W heating 2150W Power input cooling 920W heating 930W Rated current cooling 3 9A heating 4 0A Max input 1020W Max current 4 4A Design system pressure hi 2900kPa low 1840kPa Max operating pressure 2400kPa Air delivery maximum 110l s Total installed weight 29kg ...

Страница 12: ...ircommand service 7 5861006 Electrical kit 8 5862010 Inside fan assembly 9 5861002 Consensate collector set 10 5861001 Weather collar assembly 11 8001012 Circullar duct 12 8002031 Combined duct brace 13 8002037 Installation fittings kit 14 5852006 Sparrow plenum assembly 15 5601051 Remote control 16 8002044 Plenum filters pair 17 5603035 Louvre replacement set 6 per set Spare Parts ...

Страница 13: ...13 Schematic Wiring Diagram ...

Страница 14: ...the inside coil in heat mode On cooling the E5 will appear if the outside coil temperature exceeds 68O C This is an indication of condenser airflow reduced or non existent or condensor fan not working sufficiently or the thermistor is out of calibration NB When in heat mode at outside temperatures above 18O C the outside fan motors may cycle on and off This is the system shedding load to avoid ove...

Страница 15: ...ssing the FAN button It is recommended that you choose AUTO Now select the desired ROOM TEMPERATURE herein referred to as SETPOINT by pressing the TEMP up or down buttons The readout will flash the setpoint temperature Keep pressing the button until it flashes your desired setpoint In approximately 5 seconds the display will resume reading the ACTUAL room temperature The compressor will have a del...

Страница 16: ... com au For spare parts enquiries please email parts aircommand com au AIRCOMMAND EUROPE Locke Leisure Products The Gables Stoneleigh Road Bubbenhall Coventry CV8 3BT United Kingdom Phone 44 2476 303 380 AIRCOMMAND AUSTRALIA 954 Port Road Albert Park South Australia 5014 Australia Phone 61 8 8345 8444 Fax 61 8 8243 0628 Contact details ...

Отзывы: