RR-M5  Micro pressure regulator for water non-relieving

Oil and grease must never be used at gas control units. Oil and grease ignite easily and can intensely react with
some gases under pressure. In special cases greases can be used, which are specified for the corresponding
application.

The use of AirCom regulator for oxygen applications is permitted only with signed units.

Special safety instructions for pressure reducers.
If devices are connected with the pressure reducer ensure via separate protection equipment that no dangerous
pressure will be built up in them. The relief valve of the pressure reducer (if available) is not applicable for these
devices as protection means.

When using cylinder pressure reducers the pressure reducer connector must directly mate with the cylinder valve
connection. The use of adaptors is not permitted.

When changing the gas type the pressure reducer must be sufficiently purged with inert gas.

3.2 Regulations and Rules

 The national rules and regulations concerning the handling of:

                     -

compressed gases

                     -

toxic gases

                     -

flammable gases

                    are to be observed.

4 Installation

4.1 Transport and Packing
Please check directly after delivery the pressure reducer for any transport damages and deficiencies

The port openings of the pressure reducer are often closed via hole plugs to prevent contamination with dirty
particles. Remove plugs just before the assembly.

In case of further disassembly close the port openings again before storing or transporting. Temporarily it can be
done using a strip of adhesive tape by sticking it to the opening.

The pressure reducer (e. g. dispatch to customer service) may only be transported in an appropriate, stable packing.

4.2 Preparation

Turn hand knob of pressure reducer counter clockwise until the range spring is complete released.

Attach pressure reducer - make sure that connections threads are matching.

To ensure that the regulator works properly, all lines have to be purged prior to installing the regulator. Deposits
and other foreign objects can damage the valve seat and influence the regulator’s behaviour.

Do not use any lubricants since this would contaminate the pressure reducer and, in the case that oxygen or nitrous
oxide is used, there is danger of combustion.

The regulator has to be installed in the line in such a way that the air flows in the direction of the arrows on the
housing (IN to OUT).

Dok-Nr.: BA-RR-M5

Page 2 of 4

Created on 2022-06-12

Содержание RR-M5

Страница 1: ... read the following safety instructions before performing installation operation and maintenance of fittings They enable to avoid dangers to people and units Handling of technical gases especially flammable or toxic gases requires knowledge of the subject observation of instructions for use and special safety measures In addition regulations and rules must be followed as applicable see 3 2 Use the...

Страница 2: ...nsport and Packing Please check directly after delivery the pressure reducer for any transport damages and deficiencies The port openings of the pressure reducer are often closed via hole plugs to prevent contamination with dirty particles Remove plugs just before the assembly In case of further disassembly close the port openings again before storing or transporting Temporarily it can be done usi...

Страница 3: ... temperature range could destroy the sealings Warning By placing and locking the handknob at a corresponding position on the adjusting screw or by placing and locking the adjusting screw at a corresponding position against the bonnet the maximum output pressure of some regulator types can be increased to a value considerably higher than the maximum output pressure signed on the unit Using a regula...

Страница 4: ...nspect for nicks and scratches on piston diaphragm Replace diaphragm and or piston repairkit 5 3 Spare Parts Only original spare parts must be used for repair or overhaul Replacement only by trained personnel You find the repairkits under www aircom net 5 4 Repairs Faulty damaged units can be send back to AirCom Pneumatic GmbH After checking the unit we will send you a cost estimate with a first d...

Отзывы: