RR-M5  Micro pressure regulator for water non-relieving



Operating Manual

1. Intended Use

Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to
effect reduction to a downstream pressure independent of the flow rate. Not for use as a
flow controller or as a shut-off valve. The  regulators from series RR-M5 are self-contained, spring loaded pressure
reducing regulators.

The general function of pressure regulators is shown in the movie link!

Movie pressure regulators

2. Information on Instructions for use

Any use of the device requires full understanding and strict observation of these instructions. The device is only to
be used for purposes specified here.

2.1. Symbols

 This symbol points to special data and/or rules and prohibitions concerning damage precaution.

              These instructions are important for working safety!

              This symbol identifies important instructions/regulations or in case of property damage danger.

3 Safety

3.1 Safety Instructions

                    Do not endanger yourself and other people. Please read the following safety instructions before
                    performing installation, operation and maintenance of fittings. They enable to avoid dangers to 
                    people and units. Handling of technical gases – especially flammable or toxic gases – requires
knowledge of the subject, observation of instructions for use and special safety measures. In addition, regulations
and rules must be followed as applicable. (see 3.2)
Use these units only as intended (see section “Intended Use”). The same is valid for the used gas: improper use can
cause damage of the unit or injury and even death of persons.

Use gas detection devices, if you work with dangerous gases. These products detect leakage and warn the
personnel.
Wear gas mask, protection glasses and protection gloves, if you work with toxic gases and provide good ventilation.
Make sure that venting openings are not clogged and toxic gases will be discharged in use with pressure reducer
and plants equipped with relief valves.

Some gases can cause suffocation, because they displace oxygen from air. Ensure good ventilation, if you work with
these gases. It is recommended to install detectors which give an alarm if there is a lack of oxygen at the working
place.

Dok-Nr.: BA-RR-M5

Page 1 of 4

Created on 2022-06-12

Содержание RR-M5

Страница 1: ... read the following safety instructions before performing installation operation and maintenance of fittings They enable to avoid dangers to people and units Handling of technical gases especially flammable or toxic gases requires knowledge of the subject observation of instructions for use and special safety measures In addition regulations and rules must be followed as applicable see 3 2 Use the...

Страница 2: ...nsport and Packing Please check directly after delivery the pressure reducer for any transport damages and deficiencies The port openings of the pressure reducer are often closed via hole plugs to prevent contamination with dirty particles Remove plugs just before the assembly In case of further disassembly close the port openings again before storing or transporting Temporarily it can be done usi...

Страница 3: ... temperature range could destroy the sealings Warning By placing and locking the handknob at a corresponding position on the adjusting screw or by placing and locking the adjusting screw at a corresponding position against the bonnet the maximum output pressure of some regulator types can be increased to a value considerably higher than the maximum output pressure signed on the unit Using a regula...

Страница 4: ...nspect for nicks and scratches on piston diaphragm Replace diaphragm and or piston repairkit 5 3 Spare Parts Only original spare parts must be used for repair or overhaul Replacement only by trained personnel You find the repairkits under www aircom net 5 4 Repairs Faulty damaged units can be send back to AirCom Pneumatic GmbH After checking the unit we will send you a cost estimate with a first d...

Отзывы: