An internal filter is provided only to stop random contamination resulting from the installation of the regulator; an
auxiliary upstream filter is recommended for use in all but the cleanest of media. Gaseous media should be free of
excessive moisture to prevent icing of the regulator at high flow rates.

4.3 Operation
Controlled outlet pressure settings are obtained by adjusting the control knob. Rotating the knob clockwise raises the
outlet pressure while a counterclockwise rotation coupled with venting of the downstream side of the regulator
plumbing lowers the outlet pressure. Final adjustment should be made in the direction of increasing pressure to
obtain the most accurate set points. These regulators will operate with any liquid or gaseous media compatible with
the wetted materials.

Pressure regulators Series 231; 232; 233; 239 and R13  are factory setted. The range can’t be changed and range
spring can’t released.

The general function of pressure regulators is shown in the movie link!

Movie pressure regulators

Final adjustment should be made in the direction of increasing pressure to obtain the most accurate set points.
These regulators will operate with any liquid or gaseous media compatible with the wetted materials.
Satisfy yourself that the pressure reducers will only be used within their admissible limiting value (see technicla
data). Operating outside the nominal temperature range could destroy the sealings.

Warning:
By placing and locking the handknob at a corresponding position on the adjusting screw or by placing and locking
the adjusting screw at a corresponding position against the bonnet, the maximum output pressure of some regulator
types can be increased to a value considerably higher than the maximum output pressure signed on the unit.  Using
a regulator with a output pressure considerably higher than the output pressure specific by the manufacturer may
have the following consequences:

a load spring compressed nearly to solid height has a different characteristic than an elongated spring, this may
negatively affect the regulator's controlling function (the harshly compressed loadspring may prevent a
complete shutoff of the main valve, the regulator would show creep). - At the risk of their permanent
deformation

internal regulator parts are exposed to stresses beyond their design. Damages caused by excessive back
pressure setting are excluded from warranty.

4.4 Shut-Down Actions

Close inlet valve.

Use up the remaining gas or drain completely.

Turn hand knob counterclockwise until the spring is completely uncharged

5 Maintenance

Do not carry out any maintenances / repairs if the pressure reducer will be under pressure.

                    The maintenance and repair may only be performed by trained experts! The inspection is recommended
every 6 months if a system has a normal duty cycle. The device is checked for outside damages and function. More
frequent maintenance may be necessary when the system is used under extreme conditions.

5.2 Trouble Shooting

Dok-Nr.: BA-R102

Page 3 of 4

Created on 2022-06-20

Содержание R102

Страница 1: ...y instructions before performing installation operation and maintenance of fittings They enable to avoid dangers to people and units Handling of technical gases especially flammable or toxic gases requires knowledge of the subject observation of instructions for use and special safety measures In addition regulations and rules must be followed as applicable see 3 2 Use these units only as intended...

Страница 2: ... check directly after delivery the pressure reducer for any transport damages and deficiencies The port openings of the pressure reducer are often closed via hole plugs to prevent contamination with dirty particles Remove plugs just before the assembly In case of further disassembly close the port openings again before storing or transporting Temporarily it can be done using a strip of adhesive ta...

Страница 3: ... destroy the sealings Warning By placing and locking the handknob at a corresponding position on the adjusting screw or by placing and locking the adjusting screw at a corresponding position against the bonnet the maximum output pressure of some regulator types can be increased to a value considerably higher than the maximum output pressure signed on the unit Using a regulator with a output pressu...

Страница 4: ...atches on piston diaphragm Replace diaphragm and or piston repairkit 5 3 Spare Parts Only original spare parts must be used for repair or overhaul Replacement only by trained personnel You find the repairkits under www aircom net 5 4 Repairs Faulty damaged units can be send back to AirCom Pneumatic GmbH After checking the unit we will send you a cost estimate with a first diagnostic Regulators wic...

Отзывы: