background image

Raleigh, NC 27604 USA

  Phone: 919-255-3220 • Toll Free:  800-849-0472 • Fax: 919-255-6120

Website: www.aircleansystems.com • Email: [email protected] 

* Product designs are subject to change without notice.                                     © 2013 AirClean

®

 Systems, Inc. #ACOM1207PS-BE rev1

OPERATOR’S MANUAL

POWDERSAFE

DUCTLESS BULK ENCLOSURE

Models:

AC794BE      AC795BE     AC796BE

Содержание POWDERSAFE AC794BE

Страница 1: ...Fax 919 255 6120 Website www aircleansystems com Email info aircleansystems com Product designs are subject to change without notice 2013 AirClean Systems Inc ACOM1207PS BE rev1 OPERATOR S MANUAL POW...

Страница 2: ...rating Instructions for Fumes and Vapors and Alarm Messages 7 Airflow Path 8 Side View with Disposal Port 9 View of Base with Bag Access and Collar 10 Controller Instructions 11 Programming Menus 11 1...

Страница 3: ...was required to protect applications from carbon dust AirClean Systems has eliminated this problem with breakthrough bonded carbon technology Bonded carbon filters are solid blocks of activated cocon...

Страница 4: ...FHEPA ACFHEPA ACFHEPA Dimensions 12 x 24 x 3 12 x 24 x 3 12 x 24 x 3 Requirements 3 4 4 Secondary HEPA Filter3 Type ACFHEPA ACFHEPA ACFHEPA Dimensions 12 x 24 x 3 12 x 24 x 3 12 x 24 x 3 Requirements...

Страница 5: ...on the cart or the counter C Remove the prefilter for inspection before use Refer to the MAINTENANCE section of this manual for complete instructions D Connect the supplied power cord to the unit and...

Страница 6: ...ide your enclosure B When working within the enclosure keep the front sash down and perform your procedure in the center to rear of the enclosure C If the low airflow alarm sounds and or lights up the...

Страница 7: ...es please call our office to verify compatibility before use in this case your filter may have another model number Direct Dial 919 255 3220 or 800 849 0472 Monday Friday 8 00 5 00 PM EST 2 Connect th...

Страница 8: ...re filtration and HEPA filtration 3 Particulate free air moves upward to C where it enters the HEPASafe filtration area This filtration is only challenged with particulate during primary filter change...

Страница 9: ...9 Disposal Port Rubber Band...

Страница 10: ...ace desired barrel on lift and center in hole of workstation 3 Raise lift so barrel breaks plane of base at a comfortable height 4 Pull top of bag out of barrel and drape around polycarb ring 5 Secure...

Страница 11: ...POWER Turns on off power to the controller and its keys This DOES NOT cut off power to the entire enclosure The main power switch is located above the power inlet on the back right hand side of the en...

Страница 12: ...larm when it sounds by touching the alarm button on the controller The visible alarm will still work FILTER This menu shows the serial number and the purchase date of the filter For every new filter i...

Страница 13: ...usly display face velocity while blower is activated PUMP Inactive key for enclosure LIGHT One touch to enable fluorescent light if installed TIMER User definable lab event timer AUX Inactive key for...

Страница 14: ...and pre filter grid are located at the back of the unit 2 Look through the slats on the pre filter grid If the prefilter is discolored the original color is green replacement is needed B To replace th...

Страница 15: ...uts and remove the filter hold down 6 Place the spent HEPA filter into the second poly bag Wipe any residue off of the filter hold down frame and any other obvious areas Place the second rag into the...

Страница 16: ...Repeat steps above for holes 2 and 3 4 For standard setup complete assembly using hole 4 For seated use complete assembly using hole 5 5 Tighten all bolts completely 6 Installation of casters should b...

Страница 17: ...Cross Piece 2 Locking Caster 2 Standard Caster 4 Washer 8 1 Washer 4 1 x Bolt 8 2 x Bolt Standard Setup For Seated Use Mounting Holes Hole 3 Hole 5 Hole 4 Hole 1 Hole 2 ASSEMBLED CART CONFIGURATIONS...

Страница 18: ...uorescent Fixture 30w 1 10 50428 Fuse 6 3a 250V Slo Blo 1 1 1 06 50481 Gas Strut 60 2 2 06 51087 Gas Strut 90 2 06 50012 Hinge Door Positioning 6 8 12 06 50053 Hinge Medium Black 3 4 5 11 52756 Keypad...

Страница 19: ...ou the product If the cause is determined to be a manufacturing fault the dealer or AirClean Systems will repair or replace all defective parts to restore the unit to operation Under no circumstances...

Страница 20: ...ery NOTE Do not return any materials without authorization from AirClean Systems Products returned without prior authorization will not be accepted AirClean Systems and its dealers are not responsible...

Страница 21: ...Woodard Drive Raleigh NC 27604 Phone 919 255 3220 Toll Free 800 849 0472 Fax 919 255 6120 Visit AirClean Systems on the Internet at http www aircleansystems com Email AirClean Systems at info airclean...

Страница 22: ...aleigh NC 27604 Phone 919 255 3220 Toll Free 800 849 0472 Fax 919 255 6120 E mail info aircleansystems com Product designs are subject to change without notice 2013 AirClean Systems Inc ACOM1207PS BE...

Отзывы: