TROUBLESHOOTING
The following instructions are intended for qualified service personnel only.
Disconnect power before servicing the unit.
The motor is operating, but no air is drawn into the unit.
Reason
Solution
The fan is rotating in wrong direction.
(The fan must be rotating clockwise)
Turn off the power. Swap each 2 of the R/S/T cables in the
main power supply unit. Turn on the power again and make
sure the fan is rotating clockwise.
The motor does not start after switching the power on.
Reason
Solution
A.
Incorrect power voltage is supplied.
B.
Power switch is faulty.
A.
Check whether the supplied power voltage is correct.
B.
Please contact us to replace the power switch
Machine is making a loud noise.
Reason
Solution
A.
The air inlet is jammed
B.
The air hose is deformed or
squashed
A.
Check and clean the shielding net of the inlet.
B.
Check the position of the air hose to make sure the
air is flowing smoothly.