background image

7.    The unit’s water inlet is at the right hand side and the water outlet is at the left 

hand side.    They are not reversible during plumbing work.     

8.    After the plumbing work is complete, take two PVC tubes off from the desiccant 

cartridge on the top of the unit.    The two PVC tubes are on the right hand side.           

9.    Plug the power cord into a GFCI power outlet.    The power indicator will turn on 

automatically.     

10. Turn all three shutoff valves on and let the fresh water go through the unit, and 

then, open the faucet.     

11. Ozonated water is automatically produced by turning on the faucets. Once 

the faucet is turned on; the water goes through the unit and triggers the flow 

switch. The ozone generator is then turned on and begins producing ozonated 

water. 

12. The maximum water flow rate is 21 Liters per minute. The minimum water flow 

rate to receive ozonated water is 13 Liters per minute.    It is strongly 

recommended to use a flow rate from 13 L/min to 21 L/min to obtain a proper 

ozone concentration of ozonated water.     

13.

 

If the water flow rate of the main water pipe is under 13 L/min, an additional 

water motor will need to be installed at the front of the water filter to accelerate 

water flow. 

 

Controls 

1.    Open the faucet to the largest flow rate or at least the medium flow rate.    The 

power on the ozone generator will be turned on automatically and ozonated 

water will be supplied to the faucet simultaneously.     

2.    Close the faucet to stop water.    The power will be turned off automatically. 

 

Maintenance 

1.    The desiccant cartridge on the top of the unit should be replaced every three 

months by refilling the cartridge with new desiccators.     

2.    The water filter also needs to have its cartridge replaced every three months to six 

months depending on the water quality.    To replace the water cartridge, first 

turn off the shutoff valves on both sides of the water filter, and then replace the 

cartridge with a new one.     

3.    Once the water goes through the unit, like when fixtures and appliances are in use, 

the LED indicators of “Action” and “Ozone A, B, C, D” should be lit.    If any of 

the LEDs are not lit, please call for service.     

4.    The outside of the unit is made of stainless steel in the high gloss grade.    It can 

be cleaned with a moist paper towel.    Do not use a cleaning solution on its 

Отзывы: