Parts Included.............................................................3

Setting up your Nomad II Compressor .......................4

Operation Instructions: 110V or 220V outlet ............5-6

Operation Instruction: 12V Battery ..........................7-8

Operation the Lights....................................................9

Installing the Foot Extensions.....................................9

Lubricating your Nomad II Compressor ....................10

Output Air Filter Replacement ..................................10

Purging the Lubrication System................................ 11

Basic Maintenance ................................................... 11

Troubleshooting ........................................................12

Warranty ...................................................................13

2

                                                             YOU AND OTHERS WITH YOU SHOULD ALWAYS
                                                             WEAR SHOOTING GLASSES TO PROTECT YOUR 
EYES. READ ALL INSTRUCTIONS BEFORE USING. BUYER AND USER HAVE THE 
RESPONSIBILITY TO OBEY ALL LAWS ABOUT THE PURCHASE, USE AND OWNERSHIP 
OF THIS AIRGUN.

DANGER

!

DANGER OF EXPLOSION!

Overfilled compressed air cylinder

16

Do NOT exceed maximum fill pressure of 200 bar/ 2900 psi at room temperature!

IMPORTANT

!

17

18

19

IMPORTANT

                                                             THIS AIRGUN IS INTENDED FOR USE BY THOSE 
                                                             16 YEARS OF AGE OR OLDER.

!

WARNING:

!

                                                      DO NOT INHALE DUST FROM LEAD PROJECTILES
                                                      OR PUT THEM IN YOUR MOUTH. WASH HANDS 
AFTER HANDLING LEAD. SOME BBs MAY CONTAIN LEAD, A CHEMICAL KNOWN 
TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS 
(OR OTHER REPRODUCTIVE HARM).

                                            

DO NOT OVERFILL AIR CYLINDERS OR AIR GUN

                                                 TANKS, AS THIS CAN CAUSE SERIOUS INJURY OR 
DEATH.  NEVER SET THE OUTPUT PRESSURE/AUTO SHUT OFF ABOVE 4500 PSI (310 
BAR).

WARNING 

!

Do NOT exceed maximum fill pressure of your cylinder at room temperature!

                                                  

YOU AND OTHERS WITH YOU SHOULD

                                                        ALWAYS WEAR SAFETY GLASSES TO 
PROTECT YOUR EYES. READ ALL INSTRUCTIONS BEFORE USING. 

IMPORTANT

!

© Air Venturi

®

 2018   /    www.airventuri.com   /    216-292-2570

  

                                                  

THIS PRODUCT IS MADE TO FILL PRE-CHARGED

                                                         PNEUMATIC (PCP) AIR RIFLES AND PISTOLS 
DIRECTLY. THIS PRODUCT SHOULD NOT BE USED TO FILL STAND ALONE SCUBA 
OR SCUBA TANKS/CYLINDERS.  FILLING SCBA OR SCUBA TANKS/CYLINDERS MAY 
DAMAGE THE COMPRESSOR AND WILL VOID YOUR WARRANTY.   

IMPORTANT

!

Содержание NOMAD AV-MCOMP4500

Страница 1: ...User Instruction Manual Nomad II 4500 PSI Portable Air Compressor AV MCOMP4500 2 Ver 1 10 18...

Страница 2: ...IS INTENDED FOR USE BY THOSE 16 YEARS OF AGE OR OLDER WARNING DO NOT INHALE DUST FROM LEAD PROJECTILES OR PUT THEM IN YOUR MOUTH WASH HANDS AFTER HANDLING LEAD SOME BBs MAY CONTAIN LEAD A CHEMICAL KNO...

Страница 3: ...xtensions 11 3 prong power cord not pictured Air Venturi 2018 www airventuri com 216 292 2570 Lubrication Port Cooling Fan Pressure Gauge Adjustable Auto shut Off Burst Disc Pressure Release Valve Fil...

Страница 4: ...g 2 3 Locate the adjustment window on the power converter fig 3a It will be located behind wires take care not to dislodge or disconnect any of the wires while adjusting Using an allen key move the sw...

Страница 5: ...ed to cock the gun before starting the fill process Consult the owner s manual of your airgun for further instructions 8 Once these steps are complete depress the POWER RESET button The LOAD gauge wil...

Страница 6: ...on to resume filling the Nomad II will automatically stop after a few seconds of running 10 Once the pre set fill pressure is reached the compressor will stop fig 10 NOTE The cooling fans will continu...

Страница 7: ...irventuri com 216 292 2570 CAUTION Always check and make sure the collar on the female quick disconnect is in the forward position and secure on the male fitting you are connecting it to It is recomme...

Страница 8: ...is reached the compressor will stop fig 10 NOTE The cooling fans will continue to run 11 Release Bleed the pressure in the system by turning the pressure release bleed screw counter clockwise fig 11 1...

Страница 9: ...perational depress the symbol on the red switch fig 2 Installing the Feet Extensions Included with your Nomad II are feet extensions that will position the unit higher off of the surface the unit is o...

Страница 10: ...e the filter housing by screwing the small and large halves together turning the large half clockwise until it is hand tight fig 5 6 Re attach the female quick disconnect to the compressor by pulling...

Страница 11: ...LOAD gauge still reads 28 or higher 2 If fill times increase without any signs of leaking 3 Once every 20 30 fills Turn on the Nomad II compressor and open the Moisture Release Valve on the underside...

Страница 12: ...In the unlikely event that your compressor malfunctions DO NOT ATTEMPT TO FIX THE PROBLEM YOURSELF Please call Air Venturi s service line so we can address any issues or have you return the compresso...

Страница 13: ...incidental or consequential damages so the above limitation or exclusion may not apply to you Warranty claims Call Air Venturi at 216 220 1180 before returning any product Implied Warranties Any impli...

Страница 14: ...14 Notes Air Venturi 2018 www airventuri com 216 292 2570...

Страница 15: ...15 Notes Air Venturi 2018 www airventuri com 216 292 2570...

Страница 16: ...AIR VENTURI 5135 Naiman Parkway Cleveland OH 44139 Ph 216 292 2570 fax 216 373 0086...

Отзывы: