Air Vantage Tools AE-001003 Скачать руководство пользователя страница 8

Brushless Electric Belt-Sander Overload and Overheat Protections

7

(1)  2-Step Overload Protection

 

a) The LED indicator will turn from a flashing green light into a flashing red light whenever the PCB detects a 

power overload. 

b) The tool will stop automatically within approximately 5 seconds to prevent long-term overloading damage. 

The LED indicator will flash red until the tool stops. 

c) Release the lever and push again to restart the Belt-Sander. The LED indicator will turn from a flashing red 

light back into a flashing green light.

(2)  Motor Overheat Protection

 

a) The Belt-Sander detects for 2 temperature points (T1&T2) to initiate the overheat protection system. T2 is the 

higher temperature. 

b) When the motor temperature rises to T1, the tool speed may drop with heavy sustained usage, but may not 

affect the speed with lighter usage. At T1, the LED indicator will flash red 3 times periodically. The Belt-Sander 

can resume operation once it has fully cooled down and the LED indicator has turned back to a flashing green 

light.

c) If not given an opportunity to cool down when motor temperate has reached T1, the temperature of the motor 

will reach T2. The tool will automatically shut down automatically with 3 beeping sounds; the LED indicator will 

also flash red 3 times periodically. Wait until the motor has completely cooled down and the LED indicator has 

turned back to a flashing green light. During the cooling period, the user will hear 3 beeping sounds when 

pressing down the lever. This shows that the tool is still under Overheat Protection mode.

(3)  PCB Heat Protection

 

When the PCB reaches the protection point, the tool will stop automatically with 5 beeping sounds; the LED 

indicator will turn into a flashing red light. The LED indicator will keep flashing red until the PCB has fully cooled 

down. Once the PCB has fully cooled, it will turn back into a flashing green light. The tool can then resume 

operation by pressing the lever again.

 

Overload

Stop

5sec

Flash Green Light

Flash Red Light

Restart

Flash Green Light

Normal use

Flash Green Light

Protection Point 

Stop Point 

Normal use

T1

T2

Cool Down 

Cool Down

 ( 3 Flash Red Light )

3 Flash Red Light

* Speed drop 

   with heavy usage

Revision : 2018-08

B-E1BS01-AV-8

3 beeping sounds

Содержание AE-001003

Страница 1: ...INSTRUCTION MANUAL 1 2 in x 18 in 12 7 mm x 457 2 mm 20 000 RPM min 4637 SFPM 1413 SMPM WARNING For your personal safety READ and UNDERSTAND before using SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE O...

Страница 2: ...In observance of European Directive 2002 96 EC on waste electric and electronic equipment and its imple mentation in accordance with national law electric equipment that have reached the end of their...

Страница 3: ...nt such as dust mask non skid safety shoes hard hat or hearing protection used for appropri ate conditions will reduce personal injuries 11 Avoid accidental starting Ensure the switch is in the off po...

Страница 4: ...or for the material and application you are working with 5 Always use safety glasses or goggles Ordinary eye or sun glasses are NOT safety glasses 6 Hold the tool firmly with both hands 7 Make sure th...

Страница 5: ...1 2 3 6 4 5 7 8 10 11 12 13 39 42 14 15 40 16 9 17 19 20 21 22 18 23 43 26 27 30 27 22 31 32 33 34 35 36 37 38 41 29 28 43 36 4 24 25 22 Revision 2018 08 B E1BS01 AV 8...

Страница 6: ...DC 110 120V ASSEMBLY 1 20 EOSB0047 PCB DC 220 240V ASSEMBLY 21 S6 3006A HEX SOCKET BUTTON HEAD SCREW M3x6 2 22 S6 3008A HEX SOCKET BUTTON HEAD SCREW M3x8 9 23 EOSB0019 MOTOR HOUSING RIGHT 1 24 EOSB002...

Страница 7: ...t into the threaded hole on the Contact Arm so the Contact Arm is as straight as possible 9 Install the abrasive belt and secure the Belt Cover 10 Connect the electric power supply and adjust belt tra...

Страница 8: ...reen light c If not given an opportunity to cool down when motor temperate has reached T1 the temperature of the motor will reach T2 The tool will automatically shut down automatically with 3 beeping...

Страница 9: ...AirVANTAGE Tools 1966 West Holt Ave Pomona CA 91768 Telephone 909 620 0788 No 530 1 Sec 2 Guoling Rd Zhongli Dist Taoyuan City 320 Taiwan R O C...

Отзывы: