Air Uno Gruppo Incasso 60 Скачать руководство пользователя страница 9

 

4.3 Carbon Filters 

 
The hood can be used with active carbon filters which 
traps the cooking smells. There are either polyester or 
long life carbon filters and these are situated behind 
the grease filters. 
 

4.3.1 Polyester Carbon Filters 

 
These  cannot  be  reused  or  washed  and  must  be 
periodically  changed  (every  4  months  if  the  hood  is 
used for 2 hours every day). Saturated filters could be 
a  fire  hazard.  The  filters  in  the  Murano  Evo  are 
circular. 
 

4.3.2 Long Life Carbon Filters 

 
These  can  be  cleaned  and  reactivated.  The  filter 
should  be  cleaned  every  other  month  if  used 
normally. The filter is best cleaned in a dishwasher at 
the  highest  temperature  using  normal  washing 
detergent. The filter should be washed on its own to 
prevent  particles  of  food  fastening  in  it  and  then 
causing an unpleasant smell later on (Fig 17).  
 
 
 
 
 

Fig 17 

 
To reactivate, the carbon filter should be dried in the 
oven. Choose upper/lower heat and maximum 100°C 
and  dry  the  filter  for  10  minutes  (Fig  18).  The  filter 
must  be  changed  when  it  no  longer  absorbs  the 
cooking smells sufficiently. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig 18 

 

4.4 Cleaning the Hood 

 
The  surfaces  of  the  hood  should  be  cleaned 
frequently, to avoid the risk of having to remove built 
up and encrusted deposits and stains. 
For  the  painted  or  copper  plated  hoods  just  a  soft 
cloth  with  warm  water  and  a  neutral  detergent.  Do 
not pour the detergent directly onto the hood or use 
powdery or abrasive products. For the stainless steel 
hood, use special products and cloths for satin finish 
stainless steel  (not abrasive, corrosive detergents or 
detergents containing chloride), ensuring to clean in 
the same direction as the satin finish. 
Do not use aggressive products, chemical solvents or 
derivatives of oil distillates that could leave oily traces 
which could cause oxidation and polymerisation. 
 
The  manufacturer  accepts  no  responsibility  for 
damage to the surface of the hood due to failure to 
respect these instructions. 
 

5.

 

Technical Data 

 

Murano Evo 90 & H850 Motor 

Control 

Soft touch/remote control 

Colour/finish 

Black glass 

Lighting 

2 x LED (4000K) 

Airflow (m

3

/h) 

335-750 

Pressure (Pa) 

566 

Noise (db) 

51-62 

Power (W) 

235 

Voltage (V) 

220-240 

Outlet Width (mm) 

150 

Energy Class 

Weight (kg) 

30 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

65°C 

100°C 

10 min 

Содержание Gruppo Incasso 60

Страница 1: ...1 Murano Evo 90 Wall Hood Installation User Instructions Please read these instructions carefully before installing and operating this appliance...

Страница 2: ...lectrical Wiring 6 8 3 2 1 Electrical Wiring Diagram 7 3 2 2 Controls 8 4 Use Maintenance 8 9 4 1 Changing the Light Bulbs 8 4 2 Cleaning the Metal Filters 8 4 3 Carbon Filters 9 4 3 1 Polyester Carbo...

Страница 3: ...prevent accidents the instructions given in this booklet must always be followed Before beginning any operation the user or whoever is preparing to operate on the appliance must have read and underst...

Страница 4: ...hood is used with cooking appliance 3 Installation The minimum safety distance between the bottom of the hood and the top of the cooking hob must be 550mm Fig 1 smaller distances must be previously a...

Страница 5: ...ed Fig 4 Fig 4 3 Attach brackets to wall using plug and screws Fig 5 Fig 5 4 Hang the Murano Evo over the bracket and fix with screws Fig 6 Fig 6 5 Mark the two other screw positions Fig 7 Fig 7 6 Dri...

Страница 6: ...hat it does not pass through any holes without a cable clamp For direct connection to the electrical mains it is necessary to provide a device that ensures disconnection from the electrical mains with...

Страница 7: ...7 3 2 1 Electrical Wiring Diagram To motor plug Supply Blue Grey White Black Red Blue Brown Blue Brown To control buttons on hood To light transformer...

Страница 8: ...ing or maintenance work turn the power off to the hood by turning the main switch to 0 OFF 4 1 Changing the Light Bulbs 12V halogen G4 attachment Use a screwdriver to unscrew the glass support ring Fi...

Страница 9: ...ed when it no longer absorbs the cooking smells sufficiently Fig 18 4 4 Cleaning the Hood The surfaces of the hood should be cleaned frequently to avoid the risk of having to remove built up and encru...

Страница 10: ...10 6 Dimensions 900 150 492 444 130 460 39...

Страница 11: ...11 Back Outlet Option 157 335 150 450 450 94 5 444...

Страница 12: ...of all contents of this leaflet is vested in CD UK Ltd t a Air Uno Any part may not be reproduced without permission The contents of this leaflet are accurate at the date of printing but because CD UK...