5.10.2 Selecting a Timed Zone

 

 

When the  timer  is waiting  for  a zone  selection,  the 
timed  zone  is  selected  by  pressing  any  zone  key.  A 
beep  sounds  and  the  LED  next  to  the  zone  display 
starts blinking if no power level is selected, or is on if 
any power level is selected. The timer display starts 
blinking indicating that the time has to be selected.

 

 
 
 
 
 

 
 
 
 
 
 

Fig 15

 

 

The  user  can  select  only  one  zone  at  a  time.  The 
zone selection can be done beginning from timer off 
status.

 

The zone must always be selected before the time s 
set.  If  when the  timer  is waiting  for  zone  selection, 
the  timer  [+TIMER]  or  [

-

TIMER]  key  is  pressed,  the 

timer is switched off. If the zone is not selected in 10 
seconds, the timer is switched off.

 

 

5.10.3 Selecting the Time

 

 

When  the  timer  is  waiting  for  a  time  selection,  the 
timer  value  can  be  selected  between  1  and  99 
minutes by touching the [+TIMER] or 

[

–TIMER] keys.

 

If  the  [+TIMER  or  [

-

TIMER]  key  associated  with  the 

timer is held down, the changed speed is increased 
automatically.  This  makes  it  possible  to  reach  the 
desired time setting quickly.

 

 
 
 
 
 
 

Fig 16

 

 

If the time is not selected in 10 seconds, the timer is 
switched  off.  If  the  selected  time  is 

“00” 

after  10 

seconds the timer is switched off.

 

 
 

5.10.4 Starting Timer Countdown

 

 

The  countdown  starts  10  seconds  after  the  last 
operation over the [+TIMER] or [

-

TIMER] key. A beep 

sounds  and  the  timer  display  stop  blinking  and  the 
zone LED stops if any power level is selected.

 

 
 
 
 
 

Fig 17

 

 

The last minute will be displayed in seconds.

 

 

5.10.5 Changing the Time

 

 

When  the  timer  is  in  countdown  the  user  can 
change  the  time  at  any  time  by  touching  the 
[+TIMER]  or  [

-

TIMER]  keys,  the  countdown  stops 

and the timer changes to time selection status.

 

 

5.10.6 Timer Countdown End

 

 

When  the  time  set  on  the  timer  has  run  out,  the 
timed zone is switched off, the timer display and the 
timed  zone  LED  starts  blinking  and  a  timer  alarm 
beep sounds for one minute.

 

 
 
 
 
 

Fig 18

 

 

The timer alarm can be cancelled by the user at any 
time,  even  during  the  first  minute  of  the  alarm. 
When  the  timer  is  in  alarm  status,  by  pressing  any 
key of the touch control the timer is switched off.

 

 
 
 
 
 
 
 

Fig 19

 

 
 
 

Содержание Diamond 60

Страница 1: ...Diamond 60cm Hob Extractor Installation User Instructions Please read these instructions carefully before installing and operating this appliance ...

Страница 2: ...oster Function 8 9 5 6 Switching Off a Zone 9 5 7 Power Management 9 5 7 1 Setting the Hobs ECO Power Limit 9 10 5 7 2 Power Management for ECO Hob 10 5 8 Keylock 10 5 9 Zone Automatic Switch Off 10 5 10 Operating the Timer 10 12 5 10 1 Activating the Timer 10 5 10 2 Selecting a Timed Zone 11 5 10 3 Selecting the Time 11 5 10 4 Starting Timer Countdown 11 5 10 5 Changing the Time 11 5 10 6 Timer C...

Страница 3: ...7 3 Cross Section of the Exhaust Air Ducting 16 7 4 Exhaust Material Ducting Shape 17 7 5 Length of the Exhaust Ducting Curves Bends 18 19 7 6 Recirculating Option 20 8 Electrical Connection 20 9 Troubleshooting 21 23 9 1 Displaying Special Statuses 21 9 2 Errors Alarms 21 23 9 2 1 Appliance Errors 21 22 9 2 2 Zone Errors 22 23 10 Maintenance and Cleaning 23 24 11 Technical Data 24 12 Energy Label...

Страница 4: ...carrying out any cleaning or maintenance operation make sure in advance that the appliance is isolated from the mains electricity supply Incorrect installation or faulty maintenance not conforming to the requirements set out in this booklet can cause harm to people animals or property In such cases Air Uno is absolved from any civil or criminal responsibility This product complies with EU Directiv...

Страница 5: ...scretion either repair or replace the goods Free of Charge including any carriage costs This is based on the following conditions 1 The product has been fitted installed as per our instructions 2 The product has been used for normal domestic purposes only and in accordance with the manufacturer s operating and maintenance instructions 3 The product has been serviced maintained repaired taken apart...

Страница 6: ... the following information ready The details of the Silver label A description of the fault and any unusual behaviour by the cooker hood before the failure occurred The installation date 4 Extractor Operation The extractor is operated by a capacitive rotary slider When first turned on the extractor will always turn on at speed 3 V3 Intensive speed V10 is set for a maximum of 5 minutes and then the...

Страница 7: ...pplied to the hob After the touch control has conducted its initial calibration process approx 3s any cooker hood or other lighting can be switched on as normal and will not affect the operation of the touch control 5 2 Basic Control Functions The control allows different layout configurations Full induction up to 2 zones with different zone diameters Keylock function Indication of residual heat f...

Страница 8: ...rease decrease a beep sounds and the corresponding display shows the new power level The keys will be locked if The hob is off or The key lock is activated KEYLOCK LED on or There is any zone or appliance error If the finger is held down on the key the action is repeated twice every second The key increases the power level to whereas the key decreases the power level to 0 Fig 3 With the zone at po...

Страница 9: ...ECO Power Limit During the first 30 seconds after plugging in the appliance The keylock has to be unlocked and all zones off Press at the same time the zones and keys Fig 8 Once this has been done a beep sounds and Po will be in the timer display and the actual hob power limit will be in the left and right zone displays Fig 9 For selecting a new power limit Touching either the or key the power lim...

Страница 10: ...nd the KEYLOCK When the hob is off the key lock function locks all the keys including the general ON OFF key The key lock is always activated at the start up of the control Fig 13 5 9 Zone Automatic Switch Off If the power level is not changed during a preset time the corresponding zone turns off automatically The maximum time a zone can stay on depends on the selected power level 5 10 Operating t...

Страница 11: ...nged speed is increased automatically This makes it possible to reach the desired time setting quickly Fig 16 If the time is not selected in 10 seconds the timer is switched off If the selected time is 00 after 10 seconds the timer is switched off 5 10 4 Starting Timer Countdown The countdown starts 10 seconds after the last operation over the TIMER or TIMER key A beep sounds and the timer display...

Страница 12: ... with normal operation The induction microcontroller software version is shown by pressing at the same time the left and right zone keys and the keylock key Fig 22 6 Installation 6 1 Safety Instructions Before beginning any cleaning or maintenance operation unplug the appliance or switch off the electric mains The duct of the extractor must not be connected to a duct used for the discharge of fume...

Страница 13: ... and fat fires with water Suffocate the fire for example by using a lid Do not place any flammable liquids in the vicinity of the hob If there are any cracks fissures or fractures in the glass ceramic switch the device off immediately Do not touch the hot hob Keep children away from the hot hob unless they are under constant supervision Do not use the hob surface as a kitchen worktop Do not use an...

Страница 14: ...under the edge of the hob to seal the product to the worktop 7 Ducting When the extractor is used in the duct version it must be connected to an outside wall vent Ø150mm round or 220x90mm rectangular ducting must be used Ducting with a smaller diameter could cause airflow issues and invalidate the warranty 7 1 Ducting Assembly In a 600mm cupboard the back panel will require a cut out for the ducti...

Страница 15: ...into one another as shown in Fig 23 Fig 23 02TP822 D 02TP824 D 02TP820 D 02TP820 D 02TP823 D 02TP823 D Min 40mm Minimum Cupboard Depth 600mm Max 490mm Max 490mm Max 490mm 510mm 600mm 50mm 266mm 02TP823 D 02TP820 D 02TP823 D 02TP824 D 100mm plinth 391mm ...

Страница 16: ...outing length and design A cross section that is too narrow will result in significant losses in the airflow rate and increase noise level The ventilation performance of the cooker hood is the key factor for determining the ducting cross section The more powerful the ventilation performance the greater the ducting cross section must be As a rule the larger the cross section the less counter pressu...

Страница 17: ... the flapping film generates noise This type of ducting is prone to crushing which will create a poor air flow A distinction is made between round and flat channels Flat channels are often used in practice for both visual and technical reasons It used to be believed that the flow conditions in flat channels were less favourable However this no longer applies as a general rule Recent developments i...

Страница 18: ...s with largest possible radius are advisable The smaller the bend radius the greater the counter pressure Corners at right angles should also be avoided if possible because these lead to even greater pressure losses and therefore a loss of performance TIP The following rule of thumb applies for good duct routing The distance between two bends should be at least 1m although 1 5m is better Optimal f...

Страница 19: ...different duct types and flat channels indicates the extent to which the material used can influence airflow loss COMPARISON BETWEEN CHANNEL SYSTEMS WITH A SQUARE CROSS SECTION COMPARISON BETWEEN CHANNEL SYSTEMS WITH A ROUND CROSS SECTION ...

Страница 20: ... it from the electricity supply with one of these devices The earth wire must be sufficiently long so that if the strain relief fails the live wires of the connecting cable are subjected to tension before the earth wire Any superfluous cable must be removed from the installation area beneath the appliance Make sure that the local mains voltage is the same as the voltage on the rating label Full pr...

Страница 21: ... of the error disappears all displays are deactivated and the hob returns to normal operation Special status Visualization Priority Order Start conditions End Conditions Action Zone Status Zone Display Front Zone Display back Power increment not allowed only for ECO models Asked hob power Hob ECO power limit 2 sec Power increment not allowed On Off r Zone without suitable pan or without pan 2 No p...

Страница 22: ...ualisation Priority Order Error Recovery Action All Zone Displays front 0 5 sec back 0 5 sec Microcontroller fault App off F0 On Off key emitter fault When the fault disappears App off FA On Off key receiver fault When the fault disappears App off FC User interface temperature sensor short circuit When the fault disappears App off FE User interface temperature sensor open circuit When the fault di...

Страница 23: ... When the fault disappears Left or right side zones Off F6 10 Maintenance and Cleaning Before any maintenance or cleaning disconnect the appliance from the mains After each use when cool clean the hob eliminating even the small residues which when the hob is switched on again can become impossible to remove Only use suitable products avoiding steel wool pads abrasive sponges and power detergents a...

Страница 24: ...ted by a flashing LED associated with the ON OFF key to reset it press the Timer button when the motor is off WARNING the accumulation of grease in the filters could generate a fire risk Cleaning Filter Kit If in recirculation mode The recirculating filter is composed by a HI FILTER This allows you to wash them by hand or in the dishwasher The filter is then regenerated in the over for 15 minutes ...

Страница 25: ...d Sound Power Emission at minimum speed dB A 48 A weighted Sound Power Emission at maximum speed dB A 65 A weighted Sound Power Emission at intensive or boost speed dB A 67 Power consumption off mode PO W 0 5 Power consumption in standby mode PS W 0 5 Time increase factor 0 9 Energy Efficiency Index EEI 51 2 Measured air flow rate at best efficiency point QBEP m3 h 420 Measured air pressure rate a...

Страница 26: ...26 13 Dimensions 510mm 580mm 0 TIMER TIMER 25 0 0 25 0 560mm 580mm 385mm 145mm 215mm 86mm 20mm 15mm BACK 150mm 266mm 116mm 5mm 485mm 510mm 380mm SIDE 150mm 266mm 116mm 5mm ...

Страница 27: ...27 ...

Страница 28: ...y West Yorkshire LS27 7JZ CD UK Ltd T A Air Uno is a company registered in England and Wales Registration No 2905619 of of this vested part not be reproduced The of this are accurate at the date of but because has a of may be and be or are The rights of the customer are not affected ...

Отзывы: