OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

Models: PAK-3 and PAK-3HI

AIr SySteMS InternAtIonAl, Inc.

829 Juniper Crescent, Chesapeake, Va, 23320

Telephone (757) 424-3967

Toll Free 1-800-866-8100

Fax No. (757) 424-5348

www.airsystems.com.

e-mail: [email protected]

this manual must be read carefully and followed by all persons who have or will have the responsibility 

for using or servicing this equipment. this equipment will perform as designed only if used according 

to the instructions. otherwise it could fail to perform as designed, causing personal injury or death.

WArnInG

Содержание PAK-3

Страница 1: ... 8100 Fax No 757 424 5348 www airsystems com e mail sales airsystems com This manual must be read carefully and followed by all persons who have or will have the responsibility for using or servicing this equipment This equipment will perform as designed only if used according to the instructions Otherwise it could fail to perform as designed causing personal injury or death WARNING ...

Страница 2: ...w Pressure Alarm Whistle Set 500 PSI Pressure Regulator 5000 PSI Max Inlet Pressure 125 PSI Max Outlet Pressure Flow Rate 80 CFM 5000 PSI Inlet Pressure and 80 PSI Outlet Pressure High Pressure Auxiliary Inlet Model PAK 3HI Only CGA 347 Male 5000 PSI MAx Relief Valve 125 PSI ASME Preset Intrinsically Safe Yes No Electronic Devices Specifications ...

Страница 3: ...red respirator pressure by turning the pressure regulator knob clockwise to increase pressure or counter clockwise to decrease pressure Partially engage a male plug into one of the respirator connections while watching the inlet pressure gauge As pressure decreases to approximately 500 PSI the low pressure whistle will begin to sound STEP 5 Open the other cylinder and verify that it is full on the...

Страница 4: ... PORTA PAK is in use STEP 1 Open the second cylinder and check the incoming pressure gauge to verify cylinder is full STEP 2 Close the spent cylinder and open the bleeder valve to relieve pressure on the hand tight nut STEP 3 Remove the drained cylinder and replace it with a full cylinder Connect the CGA 347 hand tight nut to the cylinder valve and close the bleeder valve Cylinder Change ...

Страница 5: ... 6 PRESSURE REGULATOR REG 5000NG 7 CGA 347 MALE ADAPTER PAK 3HI ONLY SS4F347AM 8 PRESSURE CAP PAK 3HI ONLY SS347CAP 9 OUTLET PRESSURE GAUGE GA20160B 10 CYLINDER STRAP HDWR113A 11 HANSEN COUPLING QDH3SL4M 11A SCHRADER COUPLING QDSSL4M 12 HANSEN DUST CAP QDH3DCAP 12A SCHRADER DUST CAP QDSCAP 13 125 PSI RELIEF VALVE VR4125BR 14 RUBBER FOOT 4 REQ D HDWR025 System Components ...

Страница 6: ...ct or InDIrect coStS eXPenSeS loSSeS or DAMAGeS ArISInG oUt oF DeFectS In or FAIlUre oF tHe ProDUct or Any PArt tHereoF The purchaser shall be solely responsible for compliance with all applicable Federal State and Local OSHA and or MSHA requirements Although Air Systems International believes that its products if operated and maintained as shipped from the factory and in accordance with our opera...

Страница 7: ...7 Notes ...

Страница 8: ...l Inc 2019 All Rights Reserved Air Systems International Inc 829 Juniper Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Manual No PAK004 Rev 3 January 2019 ...