Motor Type
Models: CVF-8EXP and SVF-10EXP
115 VAC, 60 Hz, 1/3 HP, 2.2 amps, .25 kw, Temp. Code T-4
Class I & II, Group C,D,E,F,G
Motor Type
Model: CVF-12EXP
115 VAC, 60 Hz, 1.5 HP, 9.6 amps, 1.1 kw, Temp. Code T-4
Class I & II, Group C,D,E,F,G
Outlet Size
Models: CVF-8EXP and SVF-10EXP
8” Diameter (203 mm)
(SVF-10EXP will accommodate 8” duct as well as 10” duct)
Outlet Size
Model: CVF-12EXP
12” Diameter (305 mm)
CVF-8EXP
Flow Rates
Free Air: 987 CFM (1677 cm/hr)
15 ft. of duct with one 90° bend: 730 CFM (1246 cm/hr)
15 ft. of duct with (2) 90° bends: 648 CFM (1101 cm/hr)
SVF-10EXP
Flow Rates
Free Air: 1390 CFM (2362 cm/hr)
15 ft. of duct with one 90° bend: 870 CFM (1478 cm/hr)
15 ft. of duct with two 90° bends 858 CFM (1458 cm/hr)
CVF-12EXP
Free Air: 2400 CFM (4078 cm/hr)
15 ft. of duct with one 90° bend: 2334 CFM (3967 cm/hr)
15 ft. of duct with two 90° bends 1598 CFM (2715 cm/hr)
4
-Approved for outdoor use.
-Thermally protected.
-Use only a plug certified and/or listed as explosion-proof for both Canada and the U.S., type suitable for the area of clas–
sification that it is used in.
-
Caution!
To reduce the risk of electric shock, connect only to an outlet provided with a ground fault interrupting device.
important - Please read!
Specifications
All ventilation procedures should comply with federal, state, and local regulations. Air quality should be tested prior to
ventilating a confi ned space. A purge chart is provided on our website, www.airsystems.com, help assist in estimating the
approximate time needed to ventilate confi ned spaces. Air quality should be tested continuously during confi ned space
occupancy to ensure a stable atmosphere and worker safety because atmospheric conditions can change rapidly. Addi-
tional procedures and recommendations are available from federal, state, and local agencies.
Do
not
operate these fan
unit in a vertical position or with the fl ange or guards removed.
SAFETY PRECAUTIONS
rEAD AnD FolloW All inStrUCtionS BEloW
WARNING
Fan and blower models with the “EX” or “X” designation are the
only models approved for use in hazardous locations. These
models are
NOT
approved for use in mines.