background image

10

System components: model cVF-8X220

AIR SYSTEMS INTERNATIONAL

829 JUNIPER CRESCENT

CHESAPEAKE, VA 23320

TEL 1-800-866-8100

FAX (757) 424-5348

NAME

DATE

8” EXPLOSION PROOF FAN WITH

BLACK CONDUCTIVE HOUSING

220-230 VAC/50 Hz

PREPARED

M. BONEY

4/1/14

CHECKED

S. INTRAVATOLA

4/1/14

DATE:

10/07/13

DWG NUMBER: 

CVF-8X220

REV:

0

APPROVED

D. ANGELICO

4/1/14

FILE: 

CVF-8X220

SHEET:

1 OF 1

SAFety comPonent-no SUBStitUtion

Bluffton Motor Works electric motor model no. 1933007427, part no. 

MTR043EX22 supplied with 7.62 mm lapp cable.  

Motor approvals:  ATEX DEMKO 134885U, IECEx UL 12.0034U, 

INMETRO UL-Br 12.0360U

Hazardous Location Ex d IIB Gb

Metal used on this fan contains steel with small or trace added 

elements less than 7.5% total content of magnesium, titanium, and 

zirconium.

SPeciAl conDition oF SAFe USe

User specified ATEX approved plug to meet hazardous location 

requirement.

KILLARK part no. ELAP15232

Item #23, ground lug, manufacturer part no. KA6U. wire capacity 

6-14 AWG. or 6.35 mm (1/4”) maximum.

Tip Clearance For Installed Fan, 3.00 mm (+1.0 mm/-1.5 mm)

ATEX AND IECEx Certified Product

no Unauthorized changes

Nominal dimensions of unit:

419 mm (L) X 279 mm (W) X 368 mm (H)

AIR FL

OW

Blower Output - cFm / cmH

FREE AIR 

DELIVERY

CFM / CMH

PeRFORmAnce SPecIFIcAtIOnS

1044 / 1780

870 / 1483

15 / 25 FT. DUCT

1-90

BEND

CFM / CMH

15 / 25 FT. DUCT

2-90

BEND

CFM / CMH

AIR FLOW

60 Hz

50 Hz

870 / 1478

725 / 1232

858 / 1458

715 / 1215

CVF-8X220

SVF-10X220

Item no. 35, DECAL168 is located to the left of on/off switch label 

manufactured by Flexcon Permanent Vinyl.

Item no. 36, DECAL169 is located on opposite of on/off switch label 

manufactured by Flexcon Permanent Vinyl.

Содержание CVF-12EX22

Страница 1: ...Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Manual No BLWR047 Rev 1 February 2015 OPERATING MANUAL MODELS CVF 8X220 AND SVF 10X220 PORTABLE FANS FOR HAZ...

Страница 2: ...external grounding lugs Model SVF 10X220 contains the same components except the blower housing is made of steel The units have beeen tested by Intertek and assigned ATEX and IECEx certification numb...

Страница 3: ...and determine the reason for motor overheating Check to make sure that 1 the proper extension cord gauge is used 2 check the blower intake for debris that may be clogging the air inlet or causing the...

Страница 4: ...tion NO OTHER WARRANTY EXPRESSED OR IMPLIED AS TO DESCRIPTION QUALITY MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER IS GIVEN BY AIR SYSTEMS IN CONNECTION HERE WITH UNDER NO CIRC...

Страница 5: ...le Vent STEP 4 Install universal mount on Saddle Vent and set in place with manhole lid for support STEP 5 Install duct from blower to 90 elbow STEP 6 Turn on blower or fan Warning For explosive envir...

Страница 6: ...tested continuously during confined space occupancy to ensure a sta ble atmosphere and worker safety as atmospheric conditions can change rapidly Additional procedures and recommendations are availab...

Страница 7: ...ce ohms does not exceed 750k If sufficient resistance is not achieved the duct should be removed from service STEP 4 The ON OFF switch is integrated in the motor Pull the ON OFF switch knob outward to...

Страница 8: ...t of magnesium titanium and zirconium SPECIAL CONDITION OF SAFE USE User specified ATEX approved plug to meet hazardous location requirement KILLARK part no ELAP15232 Item 23 ground lug manufacturer p...

Страница 9: ...H P N 5308921 1 13 ELA007 1 2 CONDUIT LOCK NUT ZINC COATED STEEL 1 16 MTR043EX22 ATEX APPROVED MOTOR 220 230 VAC 50 HZ 1 17 HDWR068 COUPLING NUT 10 24 X 3 4 LONG GRADE 2 1 18 FS1032X050 10 32 X 5 ROUN...

Страница 10: ...5 total content of magnesium titanium and zirconium SPECIAL CONDITION OF SAFE USE User specified ATEX approved plug to meet hazardous location requirement KILLARK part no ELAP15232 Item 23 ground lug...

Страница 11: ...0 24 X 3 4 LONG GRADE 2 STEEL 1 9 FS10X5 8TH 10 X 5 8 TRUSS HEAD PHILLIPS SCREW STEEL 2 10 ELA051 ALUMINUM GROUNDING LUG 6 14 AWG 6 35mm MAX 2 11 ELA007 1 2 CONDUIT LOCK NUT ZINC COATED STEEL 1 12 MBK...

Страница 12: ...TER EXPLOSION PROOF PLUG FOR HAZARDOUS LOCATIONS CVF CND6 Conductive Duct Canister with 6 Ft 183 cm of Conductive Duct CVF CND15 Conductive Duct Canister with 15 Ft 457 cm of Conductive Duct CVF CND25...

Страница 13: ...nt Conductive Duct Canister with 6 of Conductive Duct Conductive 90 Elbow Universal Mount 6 and 15 of Conductive Duct Conductive Saddle Vent Duct Canister Conductive 90 Elbow Universal Mount SVF 10X22...

Страница 14: ...Hazardous Location Explosive Atmospheres Guide to Equipment Certification Requirements 14...

Страница 15: ...15 EXAMINATION CERTIFICATE...

Страница 16: ...per Crescent Chesapeake Va 23320 Telephone 757 424 3967 Toll Free 1 800 866 8100 Fax No 757 424 5348 http www airsystems com e mail sales airsystems com Printed in the U S A Copyright Air Systems Inte...

Отзывы: